Iridium Oxide pH Sensor Based on Stainless Steel Wire for pH Mapping on Metal Surface

A simple technique to fabricate the iridium oxide pH sensor is useful in several applications such as medical, food processing and engineering material where it is able to detect the changes of pH. Generally, the fabrication technique can be classified into three types: electro-deposition iridium ox...

Full description

Saved in:
Bibliographic Details
Main Authors: Shahrestani, S., Ismail, M.C., Kakooei, S., Beheshti, M., Zabihiazadboni, M., Zavareh, M.A.
Format: Article
Published: Institute of Physics Publishing 2018
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85044508862&doi=10.1088%2f1757-899X%2f328%2f1%2f012014&partnerID=40&md5=c7e5fdb410521b9ead2fea8dea390208
http://eprints.utp.edu.my/20662/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Petronas
id my.utp.eprints.20662
record_format eprints
spelling my.utp.eprints.206622018-10-11T02:21:13Z Iridium Oxide pH Sensor Based on Stainless Steel Wire for pH Mapping on Metal Surface Shahrestani, S. Ismail, M.C. Kakooei, S. Beheshti, M. Zabihiazadboni, M. Zavareh, M.A. A simple technique to fabricate the iridium oxide pH sensor is useful in several applications such as medical, food processing and engineering material where it is able to detect the changes of pH. Generally, the fabrication technique can be classified into three types: electro-deposition iridium oxide film (EIrOF), activated iridium oxide film (AIROF) and sputtering iridium oxide film (SIROF). This study focuses on fabricating electrode, calibration and test. Electro-deposition iridium oxide film is a simple and effective method of fabricating this kind of sensor via cyclic voltammetry process. The iridium oxide thick film was successfully electrodeposited on the surface of stainless steel wire with 500 cycles of sweep potential. A further analysis under FESEM shows detailed image of iridium oxide film which has cauliflower-liked microstructure. EDX analysis shows the highest element present are iridium and oxygen which concluded that the process is successful. The iridium oxide based pH sensor has shown a good performance in comparison to conventional glass pH sensor when it is being calibrated in buffer solutions with 2, 4, 7 and 9 pH values. The iridium oxide pH sensor is specifically designed to measure the pH on the surface of metal plate. © Published under licence by IOP Publishing Ltd. Institute of Physics Publishing 2018 Article PeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85044508862&doi=10.1088%2f1757-899X%2f328%2f1%2f012014&partnerID=40&md5=c7e5fdb410521b9ead2fea8dea390208 Shahrestani, S. and Ismail, M.C. and Kakooei, S. and Beheshti, M. and Zabihiazadboni, M. and Zavareh, M.A. (2018) Iridium Oxide pH Sensor Based on Stainless Steel Wire for pH Mapping on Metal Surface. IOP Conference Series: Materials Science and Engineering, 328 (1). http://eprints.utp.edu.my/20662/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description A simple technique to fabricate the iridium oxide pH sensor is useful in several applications such as medical, food processing and engineering material where it is able to detect the changes of pH. Generally, the fabrication technique can be classified into three types: electro-deposition iridium oxide film (EIrOF), activated iridium oxide film (AIROF) and sputtering iridium oxide film (SIROF). This study focuses on fabricating electrode, calibration and test. Electro-deposition iridium oxide film is a simple and effective method of fabricating this kind of sensor via cyclic voltammetry process. The iridium oxide thick film was successfully electrodeposited on the surface of stainless steel wire with 500 cycles of sweep potential. A further analysis under FESEM shows detailed image of iridium oxide film which has cauliflower-liked microstructure. EDX analysis shows the highest element present are iridium and oxygen which concluded that the process is successful. The iridium oxide based pH sensor has shown a good performance in comparison to conventional glass pH sensor when it is being calibrated in buffer solutions with 2, 4, 7 and 9 pH values. The iridium oxide pH sensor is specifically designed to measure the pH on the surface of metal plate. © Published under licence by IOP Publishing Ltd.
format Article
author Shahrestani, S.
Ismail, M.C.
Kakooei, S.
Beheshti, M.
Zabihiazadboni, M.
Zavareh, M.A.
spellingShingle Shahrestani, S.
Ismail, M.C.
Kakooei, S.
Beheshti, M.
Zabihiazadboni, M.
Zavareh, M.A.
Iridium Oxide pH Sensor Based on Stainless Steel Wire for pH Mapping on Metal Surface
author_facet Shahrestani, S.
Ismail, M.C.
Kakooei, S.
Beheshti, M.
Zabihiazadboni, M.
Zavareh, M.A.
author_sort Shahrestani, S.
title Iridium Oxide pH Sensor Based on Stainless Steel Wire for pH Mapping on Metal Surface
title_short Iridium Oxide pH Sensor Based on Stainless Steel Wire for pH Mapping on Metal Surface
title_full Iridium Oxide pH Sensor Based on Stainless Steel Wire for pH Mapping on Metal Surface
title_fullStr Iridium Oxide pH Sensor Based on Stainless Steel Wire for pH Mapping on Metal Surface
title_full_unstemmed Iridium Oxide pH Sensor Based on Stainless Steel Wire for pH Mapping on Metal Surface
title_sort iridium oxide ph sensor based on stainless steel wire for ph mapping on metal surface
publisher Institute of Physics Publishing
publishDate 2018
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85044508862&doi=10.1088%2f1757-899X%2f328%2f1%2f012014&partnerID=40&md5=c7e5fdb410521b9ead2fea8dea390208
http://eprints.utp.edu.my/20662/
_version_ 1738656215418798080