Investigation of the combined effect of variable inlet guide vane drift, fouling, and inlet air cooling on gas turbine performance
Variable geometry gas turbines are susceptible to various malfunctions and performance deterioration phenomena, such as variable inlet guide vane (VIGV) drift, compressor fouling, and high inlet air temperatures.
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Published: |
2019
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85079144833&doi=10.3390%2fe21121186&partnerID=40&md5=6f8b1554a295fd249a991af04fbccffb http://eprints.utp.edu.my/23023/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Petronas |
id |
my.utp.eprints.23023 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.230232021-08-18T12:58:02Z Investigation of the combined effect of variable inlet guide vane drift, fouling, and inlet air cooling on gas turbine performance Hashmi, M.B. Lemma, T.A. Karim, Z.A.A. Variable geometry gas turbines are susceptible to various malfunctions and performance deterioration phenomena, such as variable inlet guide vane (VIGV) drift, compressor fouling, and high inlet air temperatures. 2019 Article PeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85079144833&doi=10.3390%2fe21121186&partnerID=40&md5=6f8b1554a295fd249a991af04fbccffb Hashmi, M.B. and Lemma, T.A. and Karim, Z.A.A. (2019) Investigation of the combined effect of variable inlet guide vane drift, fouling, and inlet air cooling on gas turbine performance. Entropy, 21 (12). http://eprints.utp.edu.my/23023/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
Variable geometry gas turbines are susceptible to various malfunctions and performance deterioration phenomena, such as variable inlet guide vane (VIGV) drift, compressor fouling, and high inlet air temperatures. |
format |
Article |
author |
Hashmi, M.B. Lemma, T.A. Karim, Z.A.A. |
spellingShingle |
Hashmi, M.B. Lemma, T.A. Karim, Z.A.A. Investigation of the combined effect of variable inlet guide vane drift, fouling, and inlet air cooling on gas turbine performance |
author_facet |
Hashmi, M.B. Lemma, T.A. Karim, Z.A.A. |
author_sort |
Hashmi, M.B. |
title |
Investigation of the combined effect of variable inlet guide vane drift, fouling, and inlet air cooling on gas turbine performance |
title_short |
Investigation of the combined effect of variable inlet guide vane drift, fouling, and inlet air cooling on gas turbine performance |
title_full |
Investigation of the combined effect of variable inlet guide vane drift, fouling, and inlet air cooling on gas turbine performance |
title_fullStr |
Investigation of the combined effect of variable inlet guide vane drift, fouling, and inlet air cooling on gas turbine performance |
title_full_unstemmed |
Investigation of the combined effect of variable inlet guide vane drift, fouling, and inlet air cooling on gas turbine performance |
title_sort |
investigation of the combined effect of variable inlet guide vane drift, fouling, and inlet air cooling on gas turbine performance |
publishDate |
2019 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85079144833&doi=10.3390%2fe21121186&partnerID=40&md5=6f8b1554a295fd249a991af04fbccffb http://eprints.utp.edu.my/23023/ |
_version_ |
1738656415630753792 |