Technical acceptance assurance limit of ifl� pipelines
With a worldwide aging pipeline infrastructure and increasing economic and regulatory constraints for pipeline operators, pipeline integrity issues need to be solved. While pipeline regulations not only demand inspections or monitoring of structural integrity at certain intervals, but a continuous p...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Published: |
Asian Research Publishing Network
2016
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85009187902&partnerID=40&md5=aee6717bbfbdb0de7f94905e5d1e981c http://eprints.utp.edu.my/25329/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Petronas |
id |
my.utp.eprints.25329 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.253292021-08-27T12:58:34Z Technical acceptance assurance limit of ifl� pipelines Albarody, T.M.B. Taufiq, M.B. With a worldwide aging pipeline infrastructure and increasing economic and regulatory constraints for pipeline operators, pipeline integrity issues need to be solved. While pipeline regulations not only demand inspections or monitoring of structural integrity at certain intervals, but a continuous process of verification of pipeline integrity and fitness-for-purpose. In-Field Linear Hose (IFL) offer complemented solution for both maximizing pipeline integrity preventing; corrosion, wear, leakage etc. as well as, a health monitoring tool. IFL has short rehabilitation times and rapid recommissioning, and thus represents not only an inexpensive alternative to open rehabilitation, but also a high-quality method for the renewal of pressure petroleum pipes with an anti-corroded solution. Although, IFL structure can be coiled or uncoiled several times, it embedded optical fibre for health monitoring tool assessing pipeline integrity by inspecting the pipe corrosion, metal loss, deformations, and position. Technical Acceptance Assurance for IFL� over its 20 years of design life are key deliverables of this study. Whereas, IFL failure mode is typically caused by a succession of defects or degradation that leads to loss of structural integrity. IFL Collapse, Burst, Tensile failure, Torsional failure, Fatigue failure, and Erosion are failure mechanisms expected cause potential IFL failure and need to scrutinize. This paper focuses on wrinkling of IFL under verities loading, deformation and its interaction with the outer pipe. Stresses and strains will scrutinized throughout the deformation stage, detecting possible detachment of the liner from the outer pipe and minimum loads induce wrinkles. © 2006-2016 Asian Research Publishing Network (ARPN). All rights reserved. Asian Research Publishing Network 2016 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85009187902&partnerID=40&md5=aee6717bbfbdb0de7f94905e5d1e981c Albarody, T.M.B. and Taufiq, M.B. (2016) Technical acceptance assurance limit of ifl� pipelines. ARPN Journal of Engineering and Applied Sciences, 11 (24). pp. 14248-14252. http://eprints.utp.edu.my/25329/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
With a worldwide aging pipeline infrastructure and increasing economic and regulatory constraints for pipeline operators, pipeline integrity issues need to be solved. While pipeline regulations not only demand inspections or monitoring of structural integrity at certain intervals, but a continuous process of verification of pipeline integrity and fitness-for-purpose. In-Field Linear Hose (IFL) offer complemented solution for both maximizing pipeline integrity preventing; corrosion, wear, leakage etc. as well as, a health monitoring tool. IFL has short rehabilitation times and rapid recommissioning, and thus represents not only an inexpensive alternative to open rehabilitation, but also a high-quality method for the renewal of pressure petroleum pipes with an anti-corroded solution. Although, IFL structure can be coiled or uncoiled several times, it embedded optical fibre for health monitoring tool assessing pipeline integrity by inspecting the pipe corrosion, metal loss, deformations, and position. Technical Acceptance Assurance for IFL� over its 20 years of design life are key deliverables of this study. Whereas, IFL failure mode is typically caused by a succession of defects or degradation that leads to loss of structural integrity. IFL Collapse, Burst, Tensile failure, Torsional failure, Fatigue failure, and Erosion are failure mechanisms expected cause potential IFL failure and need to scrutinize. This paper focuses on wrinkling of IFL under verities loading, deformation and its interaction with the outer pipe. Stresses and strains will scrutinized throughout the deformation stage, detecting possible detachment of the liner from the outer pipe and minimum loads induce wrinkles. © 2006-2016 Asian Research Publishing Network (ARPN). All rights reserved. |
format |
Article |
author |
Albarody, T.M.B. Taufiq, M.B. |
spellingShingle |
Albarody, T.M.B. Taufiq, M.B. Technical acceptance assurance limit of ifl� pipelines |
author_facet |
Albarody, T.M.B. Taufiq, M.B. |
author_sort |
Albarody, T.M.B. |
title |
Technical acceptance assurance limit of ifl� pipelines |
title_short |
Technical acceptance assurance limit of ifl� pipelines |
title_full |
Technical acceptance assurance limit of ifl� pipelines |
title_fullStr |
Technical acceptance assurance limit of ifl� pipelines |
title_full_unstemmed |
Technical acceptance assurance limit of ifl� pipelines |
title_sort |
technical acceptance assurance limit of ifl� pipelines |
publisher |
Asian Research Publishing Network |
publishDate |
2016 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85009187902&partnerID=40&md5=aee6717bbfbdb0de7f94905e5d1e981c http://eprints.utp.edu.my/25329/ |
_version_ |
1738656714793680896 |