Performance analysis of a thermoelectric air duct system for energy-efficient buildings
This paper describes experimental and simulation study results of an air duct system that cools down airflow by using TEMs (thermoelectric modules). This system is designated as TE-AD (thermoelectric air duct) system which consists of twenty four TEMs along with heat sink and fan for circulation of...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Published: |
Elsevier Ltd
2015
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84946097559&doi=10.1016%2fj.energy.2015.08.102&partnerID=40&md5=86da4d3fefd34d3b1d829f6a6b048bdc http://eprints.utp.edu.my/25948/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Petronas |
id |
my.utp.eprints.25948 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.259482021-08-30T08:48:29Z Performance analysis of a thermoelectric air duct system for energy-efficient buildings Irshad, K. Habib, K. Thirumalaiswamy, N. Saha, B.B. This paper describes experimental and simulation study results of an air duct system that cools down airflow by using TEMs (thermoelectric modules). This system is designated as TE-AD (thermoelectric air duct) system which consists of twenty four TEMs along with heat sink and fan for circulation of air. Both experimental and simulation results were in good agreement with each other and showed that the TE-AD system reduces room temperature in the range of 1.2-5.3 °C and humidity in the range of 5-31. The COP (coefficient of performance) of the system ranges from 0.392 to 0.679 under different operating input current for Malaysian weather conditions. By comparing TE-AD system with conventional air conditioning system, energy saving of 38.83 and CO2 emission mitigation of 38.81 was achieved with additional benefits of high reliability and refrigerant free system. © 2015 Elsevier Ltd. Elsevier Ltd 2015 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-84946097559&doi=10.1016%2fj.energy.2015.08.102&partnerID=40&md5=86da4d3fefd34d3b1d829f6a6b048bdc Irshad, K. and Habib, K. and Thirumalaiswamy, N. and Saha, B.B. (2015) Performance analysis of a thermoelectric air duct system for energy-efficient buildings. Energy, 91 . pp. 1009-1017. http://eprints.utp.edu.my/25948/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
This paper describes experimental and simulation study results of an air duct system that cools down airflow by using TEMs (thermoelectric modules). This system is designated as TE-AD (thermoelectric air duct) system which consists of twenty four TEMs along with heat sink and fan for circulation of air. Both experimental and simulation results were in good agreement with each other and showed that the TE-AD system reduces room temperature in the range of 1.2-5.3 °C and humidity in the range of 5-31. The COP (coefficient of performance) of the system ranges from 0.392 to 0.679 under different operating input current for Malaysian weather conditions. By comparing TE-AD system with conventional air conditioning system, energy saving of 38.83 and CO2 emission mitigation of 38.81 was achieved with additional benefits of high reliability and refrigerant free system. © 2015 Elsevier Ltd. |
format |
Article |
author |
Irshad, K. Habib, K. Thirumalaiswamy, N. Saha, B.B. |
spellingShingle |
Irshad, K. Habib, K. Thirumalaiswamy, N. Saha, B.B. Performance analysis of a thermoelectric air duct system for energy-efficient buildings |
author_facet |
Irshad, K. Habib, K. Thirumalaiswamy, N. Saha, B.B. |
author_sort |
Irshad, K. |
title |
Performance analysis of a thermoelectric air duct system for energy-efficient buildings |
title_short |
Performance analysis of a thermoelectric air duct system for energy-efficient buildings |
title_full |
Performance analysis of a thermoelectric air duct system for energy-efficient buildings |
title_fullStr |
Performance analysis of a thermoelectric air duct system for energy-efficient buildings |
title_full_unstemmed |
Performance analysis of a thermoelectric air duct system for energy-efficient buildings |
title_sort |
performance analysis of a thermoelectric air duct system for energy-efficient buildings |
publisher |
Elsevier Ltd |
publishDate |
2015 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84946097559&doi=10.1016%2fj.energy.2015.08.102&partnerID=40&md5=86da4d3fefd34d3b1d829f6a6b048bdc http://eprints.utp.edu.my/25948/ |
_version_ |
1738656802281619456 |