Effect of down stand depth variation on atriums upper balconies smoke contamination
In case of fire in an atrium, smoke produced is recognized as one of the major hazards for the occupants because of open spaces present in an atrium. The effect of varying the down stand depth at fire compartment on smoke contamination in upper balconies of an atrium has been investigated in this pa...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Conference or Workshop Item |
Published: |
EDP Sciences
2014
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84904994058&doi=10.1051%2fmatecconf%2f20141305010&partnerID=40&md5=ffc45b2394cab557db96a89c22fd3492 http://eprints.utp.edu.my/32259/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Petronas |
id |
my.utp.eprints.32259 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.322592022-03-29T05:02:39Z Effect of down stand depth variation on atriums upper balconies smoke contamination Hasnain, S.A. Nasif, M.S. Pao, W. Al-Waked, R. In case of fire in an atrium, smoke produced is recognized as one of the major hazards for the occupants because of open spaces present in an atrium. The effect of varying the down stand depth at fire compartment on smoke contamination in upper balconies of an atrium has been investigated in this paper. Correlation to predict the smoke contamination in upper balconies of an atrium in the presence of 0.5 m deep down stand structure has also been developed. This correlation is compared with correlations developed for 1 m deep down stand and without down stand structure by past research. The comparison results showed that when the depth of down stand structure increase, smoke contamination in upper balconies of an atrium also increases. The results also showed that smoke contamination in upper balconies of an atrium decreases when the ratio of w/d increases. The comparison of correlations from 1 m and 0.5 m deep down stand showed that the difference in smoke contamination increases when w/d < 3. By comparing the correlations from 0.5 m deep down stand and no down stand, there is very small difference in smoke contamination from both case but it is applicable for w/d < 3. © 2014 Owned by the authors, published by EDP Sciences. EDP Sciences 2014 Conference or Workshop Item NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-84904994058&doi=10.1051%2fmatecconf%2f20141305010&partnerID=40&md5=ffc45b2394cab557db96a89c22fd3492 Hasnain, S.A. and Nasif, M.S. and Pao, W. and Al-Waked, R. (2014) Effect of down stand depth variation on atriums upper balconies smoke contamination. In: UNSPECIFIED. http://eprints.utp.edu.my/32259/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
In case of fire in an atrium, smoke produced is recognized as one of the major hazards for the occupants because of open spaces present in an atrium. The effect of varying the down stand depth at fire compartment on smoke contamination in upper balconies of an atrium has been investigated in this paper. Correlation to predict the smoke contamination in upper balconies of an atrium in the presence of 0.5 m deep down stand structure has also been developed. This correlation is compared with correlations developed for 1 m deep down stand and without down stand structure by past research. The comparison results showed that when the depth of down stand structure increase, smoke contamination in upper balconies of an atrium also increases. The results also showed that smoke contamination in upper balconies of an atrium decreases when the ratio of w/d increases. The comparison of correlations from 1 m and 0.5 m deep down stand showed that the difference in smoke contamination increases when w/d < 3. By comparing the correlations from 0.5 m deep down stand and no down stand, there is very small difference in smoke contamination from both case but it is applicable for w/d < 3. © 2014 Owned by the authors, published by EDP Sciences. |
format |
Conference or Workshop Item |
author |
Hasnain, S.A. Nasif, M.S. Pao, W. Al-Waked, R. |
spellingShingle |
Hasnain, S.A. Nasif, M.S. Pao, W. Al-Waked, R. Effect of down stand depth variation on atriums upper balconies smoke contamination |
author_facet |
Hasnain, S.A. Nasif, M.S. Pao, W. Al-Waked, R. |
author_sort |
Hasnain, S.A. |
title |
Effect of down stand depth variation on atriums upper balconies smoke contamination |
title_short |
Effect of down stand depth variation on atriums upper balconies smoke contamination |
title_full |
Effect of down stand depth variation on atriums upper balconies smoke contamination |
title_fullStr |
Effect of down stand depth variation on atriums upper balconies smoke contamination |
title_full_unstemmed |
Effect of down stand depth variation on atriums upper balconies smoke contamination |
title_sort |
effect of down stand depth variation on atriums upper balconies smoke contamination |
publisher |
EDP Sciences |
publishDate |
2014 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84904994058&doi=10.1051%2fmatecconf%2f20141305010&partnerID=40&md5=ffc45b2394cab557db96a89c22fd3492 http://eprints.utp.edu.my/32259/ |
_version_ |
1738657362386878464 |