Exergetic Performance of a Cogeneration Plant at Part Load operations

A cogeneration plant can run at off-design due to change of load demand or ambient conditions. The cogeneration considered for this study is gas turbine based engine consists of variable stator vanes (VSVs) compressor that are re-staggered for loads greater than 50% to maintain the gas turbine exh...

Full description

Saved in:
Bibliographic Details
Main Authors: Baheta, Aklilu Tesfamichael, Gilani, Syed Ihtsham-ul-Haq
Format: Article
Published: 2010
Subjects:
Online Access:http://eprints.utp.edu.my/5547/1/exergetic_analysis_of_a_cogeneration_plant.doc
http://eprints.utp.edu.my/5547/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Petronas
id my.utp.eprints.5547
record_format eprints
spelling my.utp.eprints.55472014-04-01T06:12:50Z Exergetic Performance of a Cogeneration Plant at Part Load operations Baheta, Aklilu Tesfamichael Gilani, Syed Ihtsham-ul-Haq Q Science (General) A cogeneration plant can run at off-design due to change of load demand or ambient conditions. The cogeneration considered for this study is gas turbine based engine consists of variable stator vanes (VSVs) compressor that are re-staggered for loads greater than 50% to maintain the gas turbine exhaust gas temperature at the set value. In order to evaluate the exergetic performance of the cogeneration, exergy model of each cogeneration component is formulated. A 4.2 MW gas turbine based cogeneration plant is analysed for a wide range of part load operations including the effect of VSVs modulation. For loads less than 50%, the major exergy destruction contributors are the combustor and the loss with the stack gas. At full load, the exergy destructions in the combustor, turbine, heat recovery, compressor and the exergy loss with stack gas are 63.7, 14.1, 11.5, 5.7, and 4.9%, respectively. The corresponding firstand second law cogeneration efficiencies are 78.5 and 45%, respectively. For comparison purpose both the first and second law efficiencies of each component are represented together. This analysis would help to identify the equipment where the potential for performance improvement is high, and trends which may aid in the design of future plants 2010 Article PeerReviewed application/msword http://eprints.utp.edu.my/5547/1/exergetic_analysis_of_a_cogeneration_plant.doc Baheta, Aklilu Tesfamichael and Gilani, Syed Ihtsham-ul-Haq (2010) Exergetic Performance of a Cogeneration Plant at Part Load operations. Journal of Energy and Power Engineering, 4 (35). pp. 1-8. ISSN 1934-8975 http://eprints.utp.edu.my/5547/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
topic Q Science (General)
spellingShingle Q Science (General)
Baheta, Aklilu Tesfamichael
Gilani, Syed Ihtsham-ul-Haq
Exergetic Performance of a Cogeneration Plant at Part Load operations
description A cogeneration plant can run at off-design due to change of load demand or ambient conditions. The cogeneration considered for this study is gas turbine based engine consists of variable stator vanes (VSVs) compressor that are re-staggered for loads greater than 50% to maintain the gas turbine exhaust gas temperature at the set value. In order to evaluate the exergetic performance of the cogeneration, exergy model of each cogeneration component is formulated. A 4.2 MW gas turbine based cogeneration plant is analysed for a wide range of part load operations including the effect of VSVs modulation. For loads less than 50%, the major exergy destruction contributors are the combustor and the loss with the stack gas. At full load, the exergy destructions in the combustor, turbine, heat recovery, compressor and the exergy loss with stack gas are 63.7, 14.1, 11.5, 5.7, and 4.9%, respectively. The corresponding firstand second law cogeneration efficiencies are 78.5 and 45%, respectively. For comparison purpose both the first and second law efficiencies of each component are represented together. This analysis would help to identify the equipment where the potential for performance improvement is high, and trends which may aid in the design of future plants
format Article
author Baheta, Aklilu Tesfamichael
Gilani, Syed Ihtsham-ul-Haq
author_facet Baheta, Aklilu Tesfamichael
Gilani, Syed Ihtsham-ul-Haq
author_sort Baheta, Aklilu Tesfamichael
title Exergetic Performance of a Cogeneration Plant at Part Load operations
title_short Exergetic Performance of a Cogeneration Plant at Part Load operations
title_full Exergetic Performance of a Cogeneration Plant at Part Load operations
title_fullStr Exergetic Performance of a Cogeneration Plant at Part Load operations
title_full_unstemmed Exergetic Performance of a Cogeneration Plant at Part Load operations
title_sort exergetic performance of a cogeneration plant at part load operations
publishDate 2010
url http://eprints.utp.edu.my/5547/1/exergetic_analysis_of_a_cogeneration_plant.doc
http://eprints.utp.edu.my/5547/
_version_ 1738655414091776000