Assessment of waterproofing failures in concrete buildings and structures

This paper focuses on waterproofing failures in concrete buildings and structures.The objectives of this paper are three folds; (1) to determine the main factors that contribute to waterproofing failures in concrete buildings and structures (2) to discover different types of present waterproofing sy...

Full description

Saved in:
Bibliographic Details
Main Authors: Othuman Mydin, Md Azree, Mohd Nawi, Mohd Nasrun, Che Munaaim, Muhammad Arkam
Format: Article
Language:English
Published: Construction Research Institute of Malaysia (CREAM) 2017
Subjects:
Online Access:http://repo.uum.edu.my/23129/1/MCRJ%20Special%20Issue%202%20%202%202017%20166%20179.pdf
http://repo.uum.edu.my/23129/
http://www.cream.my/main/index.php/publication/download-mcrj#
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Utara Malaysia
Language: English
id my.uum.repo.23129
record_format eprints
spelling my.uum.repo.231292018-02-13T06:40:45Z http://repo.uum.edu.my/23129/ Assessment of waterproofing failures in concrete buildings and structures Othuman Mydin, Md Azree Mohd Nawi, Mohd Nasrun Che Munaaim, Muhammad Arkam HD28 Management. Industrial Management This paper focuses on waterproofing failures in concrete buildings and structures.The objectives of this paper are three folds; (1) to determine the main factors that contribute to waterproofing failures in concrete buildings and structures (2) to discover different types of present waterproofing system applied for concrete buildings and structures (3) to propose remedial waterproofing solutions of concrete buildings and structures. There are 4 case studies were carried out at Cyberjaya, Malacca, Kuala Lumpur and Seremban.Each of them consist of different type of building namely SOHO (small office), Commercial building, Hotel Building and shopping mall.The results obtained shows that the main factors that contribute to waterproofing failures in concrete buildings and structure are cracks, deteriorated waterproofing system, honeycombs in concrete and construction joint failure.At the moment there are few types of present waterproofing system applied for concrete buildings and structures such as cementitious system, sheet membrane system and liquid system.Remedial waterproofing solutions of concrete building structures includes cleaning, removing old sealant or joint, injecting appropriate epoxy or chemical grout and applying a new layer of waterproofing system. Construction Research Institute of Malaysia (CREAM) 2017 Article PeerReviewed application/pdf en http://repo.uum.edu.my/23129/1/MCRJ%20Special%20Issue%202%20%202%202017%20166%20179.pdf Othuman Mydin, Md Azree and Mohd Nawi, Mohd Nasrun and Che Munaaim, Muhammad Arkam (2017) Assessment of waterproofing failures in concrete buildings and structures. Malaysian Construction Research Journal, 2 (2). pp. 166-179. ISSN 1985 - 3807 http://www.cream.my/main/index.php/publication/download-mcrj#
institution Universiti Utara Malaysia
building UUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Utara Malaysia
content_source UUM Institutionali Repository
url_provider http://repo.uum.edu.my/
language English
topic HD28 Management. Industrial Management
spellingShingle HD28 Management. Industrial Management
Othuman Mydin, Md Azree
Mohd Nawi, Mohd Nasrun
Che Munaaim, Muhammad Arkam
Assessment of waterproofing failures in concrete buildings and structures
description This paper focuses on waterproofing failures in concrete buildings and structures.The objectives of this paper are three folds; (1) to determine the main factors that contribute to waterproofing failures in concrete buildings and structures (2) to discover different types of present waterproofing system applied for concrete buildings and structures (3) to propose remedial waterproofing solutions of concrete buildings and structures. There are 4 case studies were carried out at Cyberjaya, Malacca, Kuala Lumpur and Seremban.Each of them consist of different type of building namely SOHO (small office), Commercial building, Hotel Building and shopping mall.The results obtained shows that the main factors that contribute to waterproofing failures in concrete buildings and structure are cracks, deteriorated waterproofing system, honeycombs in concrete and construction joint failure.At the moment there are few types of present waterproofing system applied for concrete buildings and structures such as cementitious system, sheet membrane system and liquid system.Remedial waterproofing solutions of concrete building structures includes cleaning, removing old sealant or joint, injecting appropriate epoxy or chemical grout and applying a new layer of waterproofing system.
format Article
author Othuman Mydin, Md Azree
Mohd Nawi, Mohd Nasrun
Che Munaaim, Muhammad Arkam
author_facet Othuman Mydin, Md Azree
Mohd Nawi, Mohd Nasrun
Che Munaaim, Muhammad Arkam
author_sort Othuman Mydin, Md Azree
title Assessment of waterproofing failures in concrete buildings and structures
title_short Assessment of waterproofing failures in concrete buildings and structures
title_full Assessment of waterproofing failures in concrete buildings and structures
title_fullStr Assessment of waterproofing failures in concrete buildings and structures
title_full_unstemmed Assessment of waterproofing failures in concrete buildings and structures
title_sort assessment of waterproofing failures in concrete buildings and structures
publisher Construction Research Institute of Malaysia (CREAM)
publishDate 2017
url http://repo.uum.edu.my/23129/1/MCRJ%20Special%20Issue%202%20%202%202017%20166%20179.pdf
http://repo.uum.edu.my/23129/
http://www.cream.my/main/index.php/publication/download-mcrj#
_version_ 1644283701933113344