Energy efficency of chancellery building at Universiti Utara Malaysia

There are various initiatives in ensuring the optimum and efficiency usage of energy in the government owned buildings. By complying with the MS1525:2007 standard, the energy efficiency of buildings is taken as a reference to ensure the buildings meets the current standard. This paper presents a thr...

Full description

Saved in:
Bibliographic Details
Main Authors: Jamaludin, Roslan, Mohd Nawi, Mohd Nasrun, Bahaudin, Ahmad Yusni, Mohtar, Shahimi, Tahir, Mohamad Zamhari
Format: Article
Language:English
Published: Akademia Baru 2019
Subjects:
Online Access:https://repo.uum.edu.my/id/eprint/28651/1/Energy%20Efficency.pdf
https://repo.uum.edu.my/id/eprint/28651/
http://www.akademiabaru.com/arfmts.html
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Utara Malaysia
Language: English
id my.uum.repo.28651
record_format eprints
spelling my.uum.repo.286512022-04-24T10:32:16Z https://repo.uum.edu.my/id/eprint/28651/ Energy efficency of chancellery building at Universiti Utara Malaysia Jamaludin, Roslan Mohd Nawi, Mohd Nasrun Bahaudin, Ahmad Yusni Mohtar, Shahimi Tahir, Mohamad Zamhari T Technology (General) There are various initiatives in ensuring the optimum and efficiency usage of energy in the government owned buildings. By complying with the MS1525:2007 standard, the energy efficiency of buildings is taken as a reference to ensure the buildings meets the current standard. This paper presents a three years energy consumption data of the Chancellery building at Universiti Utara Malaysia. This study aims to ensure that the building is able to meet the standard requirements of the Building Energy Index (BEI). Based on MS 1525:2007 any building which implements energy efficient measures can achieve the BEI of 136kWh/m2/year. Preliminary audit conducted involves a brief review of utility and building operation, observation and a walkthrough in the building. General audit has been conducted in order to get a better understanding of major energy consumption and to collect more detailed information about the operation of the building. Data from monthly energy usage and gross floor area of the building has been collected and the BEI was calculated. Recommendation on how to improve energy saving and enhancement for building performance are presented. Several energy efficiency practices that do not involve higher operation cost or without any additional cost are also introduced. By implementing some of the good energy efficiency measures in the building enable better assessment and continuous monitoring of energy usages within the university campus. Akademia Baru 2019-06 Article PeerReviewed application/pdf en https://repo.uum.edu.my/id/eprint/28651/1/Energy%20Efficency.pdf Jamaludin, Roslan and Mohd Nawi, Mohd Nasrun and Bahaudin, Ahmad Yusni and Mohtar, Shahimi and Tahir, Mohamad Zamhari (2019) Energy efficency of chancellery building at Universiti Utara Malaysia. Journal of Advanced Research in Fluid Mechanics and Thermal, 58 (2). pp. 144-152. ISSN 22897879 http://www.akademiabaru.com/arfmts.html
institution Universiti Utara Malaysia
building UUM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Utara Malaysia
content_source UUM Institutional Repository
url_provider http://repo.uum.edu.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Jamaludin, Roslan
Mohd Nawi, Mohd Nasrun
Bahaudin, Ahmad Yusni
Mohtar, Shahimi
Tahir, Mohamad Zamhari
Energy efficency of chancellery building at Universiti Utara Malaysia
description There are various initiatives in ensuring the optimum and efficiency usage of energy in the government owned buildings. By complying with the MS1525:2007 standard, the energy efficiency of buildings is taken as a reference to ensure the buildings meets the current standard. This paper presents a three years energy consumption data of the Chancellery building at Universiti Utara Malaysia. This study aims to ensure that the building is able to meet the standard requirements of the Building Energy Index (BEI). Based on MS 1525:2007 any building which implements energy efficient measures can achieve the BEI of 136kWh/m2/year. Preliminary audit conducted involves a brief review of utility and building operation, observation and a walkthrough in the building. General audit has been conducted in order to get a better understanding of major energy consumption and to collect more detailed information about the operation of the building. Data from monthly energy usage and gross floor area of the building has been collected and the BEI was calculated. Recommendation on how to improve energy saving and enhancement for building performance are presented. Several energy efficiency practices that do not involve higher operation cost or without any additional cost are also introduced. By implementing some of the good energy efficiency measures in the building enable better assessment and continuous monitoring of energy usages within the university campus.
format Article
author Jamaludin, Roslan
Mohd Nawi, Mohd Nasrun
Bahaudin, Ahmad Yusni
Mohtar, Shahimi
Tahir, Mohamad Zamhari
author_facet Jamaludin, Roslan
Mohd Nawi, Mohd Nasrun
Bahaudin, Ahmad Yusni
Mohtar, Shahimi
Tahir, Mohamad Zamhari
author_sort Jamaludin, Roslan
title Energy efficency of chancellery building at Universiti Utara Malaysia
title_short Energy efficency of chancellery building at Universiti Utara Malaysia
title_full Energy efficency of chancellery building at Universiti Utara Malaysia
title_fullStr Energy efficency of chancellery building at Universiti Utara Malaysia
title_full_unstemmed Energy efficency of chancellery building at Universiti Utara Malaysia
title_sort energy efficency of chancellery building at universiti utara malaysia
publisher Akademia Baru
publishDate 2019
url https://repo.uum.edu.my/id/eprint/28651/1/Energy%20Efficency.pdf
https://repo.uum.edu.my/id/eprint/28651/
http://www.akademiabaru.com/arfmts.html
_version_ 1731228536467881984