Highly sensitive sensor based on 4×4 multimode interference coupler with microring resonators
This study proposes a novel optical integrated structure using only one 4x4 multimode interference (MMI) coupler with support of two microring resonators for glucose and ethanol sensor. Due to the presence of the analyte, the wavelength shift of the output spectrum is realized. The proposed structur...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
Journal of Optoelectronics and Advanced Materials
2020
|
Subjects: | |
Online Access: | http://repository.vnu.edu.vn/handle/VNU_123/89408 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Vietnam National University, Hanoi |
Language: | English |
id |
oai:112.137.131.14:VNU_123-89408 |
---|---|
record_format |
dspace |
spelling |
oai:112.137.131.14:VNU_123-894082020-08-14T09:42:44Z Highly sensitive sensor based on 4×4 multimode interference coupler with microring resonators Le, Trung Thanh Khoa Quốc tế, ĐHQGHN Glucose sensor Multimode interference Microring resonator Integrated optics This study proposes a novel optical integrated structure using only one 4x4 multimode interference (MMI) coupler with support of two microring resonators for glucose and ethanol sensor. Due to the presence of the analyte, the wavelength shift of the output spectrum is realized. The proposed structure can provide a high sensitivity of 721 nm/RIU, low detection limit of 2.8x105 and good figure of merit of 5x1016 for glucose sensing. 2020-08-14T09:42:44Z 2020-08-14T09:42:44Z 2018-07 Article Le T. T. (2018). Highly sensitive sensor based on 4×4 multimode interference coupler with microring resonators. Journal of Optoelectronics and Advanced Materials, Vol. 20, No. 5 - 6, May – June 2018, p. 264 - 270 http://repository.vnu.edu.vn/handle/VNU_123/89408 en application/pdf Journal of Optoelectronics and Advanced Materials |
institution |
Vietnam National University, Hanoi |
building |
VNU Library & Information Center |
country |
Vietnam |
collection |
VNU Digital Repository |
language |
English |
topic |
Glucose sensor Multimode interference Microring resonator Integrated optics |
spellingShingle |
Glucose sensor Multimode interference Microring resonator Integrated optics Le, Trung Thanh Highly sensitive sensor based on 4×4 multimode interference coupler with microring resonators |
description |
This study proposes a novel optical integrated structure using only one 4x4 multimode interference (MMI) coupler with support of two microring resonators for glucose and ethanol sensor. Due to the presence of the analyte, the wavelength shift of the output spectrum is realized. The proposed structure can provide a high sensitivity of 721 nm/RIU, low detection limit of 2.8x105 and good figure of merit of 5x1016 for glucose sensing. |
author2 |
Khoa Quốc tế, ĐHQGHN |
author_facet |
Khoa Quốc tế, ĐHQGHN Le, Trung Thanh |
format |
Article |
author |
Le, Trung Thanh |
author_sort |
Le, Trung Thanh |
title |
Highly sensitive sensor based on 4×4 multimode interference coupler with microring resonators |
title_short |
Highly sensitive sensor based on 4×4 multimode interference coupler with microring resonators |
title_full |
Highly sensitive sensor based on 4×4 multimode interference coupler with microring resonators |
title_fullStr |
Highly sensitive sensor based on 4×4 multimode interference coupler with microring resonators |
title_full_unstemmed |
Highly sensitive sensor based on 4×4 multimode interference coupler with microring resonators |
title_sort |
highly sensitive sensor based on 4×4 multimode interference coupler with microring resonators |
publisher |
Journal of Optoelectronics and Advanced Materials |
publishDate |
2020 |
url |
http://repository.vnu.edu.vn/handle/VNU_123/89408 |
_version_ |
1680963631484764160 |