Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital

Metro Manila is exposed to the Marikina Fault Valley system. The East and West Valley Faults, according to PHILVOCS, can generate earthquakes of magnitudes 6.2 to 7.2, respectively. According to recent studies, the effects of the ensuing ground motion can be disastrous. Thousands of people could die...

Full description

Saved in:
Bibliographic Details
Main Authors: Almero, Glenn S., Costelo, Joseph Angelo P., Manubag, Alyssa Beatriz O., Zialcita, Stephanie A.
Format: text
Language:English
Published: Animo Repository 2017
Subjects:
Online Access:https://animorepository.dlsu.edu.ph/etd_bachelors/6759
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: De La Salle University
Language: English
id oai:animorepository.dlsu.edu.ph:etd_bachelors-7403
record_format eprints
spelling oai:animorepository.dlsu.edu.ph:etd_bachelors-74032021-07-22T08:07:21Z Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital Almero, Glenn S. Costelo, Joseph Angelo P. Manubag, Alyssa Beatriz O. Zialcita, Stephanie A. Metro Manila is exposed to the Marikina Fault Valley system. The East and West Valley Faults, according to PHILVOCS, can generate earthquakes of magnitudes 6.2 to 7.2, respectively. According to recent studies, the effects of the ensuing ground motion can be disastrous. Thousands of people could die with damage to properties estimated to reach 1.8 to 2.3 trillion pesos. In a post-earthquake scenario, affected people depend on the quick recovery of lifetime systems such as hospitals and its supporting facilities. In order to ensure the functionality, resilience and serviceability of a medical facility after a large magnitude earthquake, assessment of the structural, non-structural, supporting facilities as well as non-fixed and movable equipment within the facility is necessary. In this regard, this research focuses on assessing the seismic risk of non-fixed and movable equipment inside the emergency room (ER), intensive care unit (ICU) and wards of the San Juan de Dios Educational Foundation, Inc. Hospital (SJDEFI). The primary motivation for this endeavor is that SJDEFI is a medical facility which is highly vulnerable considering it is one of the oldest hospitals in the country being constructed in 1578. The results of the probability of seismic hazard assessment (PSHA) revealed the following ground accelerations at the hospital site: (a) 10% probalility of exceedance in 50 years (MRI = 475 years) equal to 0.527g and, (b) 2% probability of exceedance in 50 years (MRI = 2,475 years) equal to 0.564g. After subjecting it to constant acceleration, the equipment's potential to overturn depends on the slenderness of the equipment since slender blocks has the potential to topple at lower accelerations. Rooms that are subjected to constant acceleration will experience significant damage when subjected to 0.5g to 0.6g acceleration and will be extensively damage at magnitudes of 0.8g or higher. 2017-01-01T08:00:00Z text https://animorepository.dlsu.edu.ph/etd_bachelors/6759 Bachelor's Theses English Animo Repository Earthquake hazard analysis--Philippines
institution De La Salle University
building De La Salle University Library
continent Asia
country Philippines
Philippines
content_provider De La Salle University Library
collection DLSU Institutional Repository
language English
topic Earthquake hazard analysis--Philippines
spellingShingle Earthquake hazard analysis--Philippines
Almero, Glenn S.
Costelo, Joseph Angelo P.
Manubag, Alyssa Beatriz O.
Zialcita, Stephanie A.
Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital
description Metro Manila is exposed to the Marikina Fault Valley system. The East and West Valley Faults, according to PHILVOCS, can generate earthquakes of magnitudes 6.2 to 7.2, respectively. According to recent studies, the effects of the ensuing ground motion can be disastrous. Thousands of people could die with damage to properties estimated to reach 1.8 to 2.3 trillion pesos. In a post-earthquake scenario, affected people depend on the quick recovery of lifetime systems such as hospitals and its supporting facilities. In order to ensure the functionality, resilience and serviceability of a medical facility after a large magnitude earthquake, assessment of the structural, non-structural, supporting facilities as well as non-fixed and movable equipment within the facility is necessary. In this regard, this research focuses on assessing the seismic risk of non-fixed and movable equipment inside the emergency room (ER), intensive care unit (ICU) and wards of the San Juan de Dios Educational Foundation, Inc. Hospital (SJDEFI). The primary motivation for this endeavor is that SJDEFI is a medical facility which is highly vulnerable considering it is one of the oldest hospitals in the country being constructed in 1578. The results of the probability of seismic hazard assessment (PSHA) revealed the following ground accelerations at the hospital site: (a) 10% probalility of exceedance in 50 years (MRI = 475 years) equal to 0.527g and, (b) 2% probability of exceedance in 50 years (MRI = 2,475 years) equal to 0.564g. After subjecting it to constant acceleration, the equipment's potential to overturn depends on the slenderness of the equipment since slender blocks has the potential to topple at lower accelerations. Rooms that are subjected to constant acceleration will experience significant damage when subjected to 0.5g to 0.6g acceleration and will be extensively damage at magnitudes of 0.8g or higher.
format text
author Almero, Glenn S.
Costelo, Joseph Angelo P.
Manubag, Alyssa Beatriz O.
Zialcita, Stephanie A.
author_facet Almero, Glenn S.
Costelo, Joseph Angelo P.
Manubag, Alyssa Beatriz O.
Zialcita, Stephanie A.
author_sort Almero, Glenn S.
title Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital
title_short Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital
title_full Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital
title_fullStr Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital
title_full_unstemmed Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital
title_sort proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: a case study: san juan de dios hospital
publisher Animo Repository
publishDate 2017
url https://animorepository.dlsu.edu.ph/etd_bachelors/6759
_version_ 1712576639955632128