Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital
Metro Manila is exposed to the Marikina Fault Valley system. The East and West Valley Faults, according to PHILVOCS, can generate earthquakes of magnitudes 6.2 to 7.2, respectively. According to recent studies, the effects of the ensuing ground motion can be disastrous. Thousands of people could die...
Saved in:
Main Authors: | , , , |
---|---|
Format: | text |
Language: | English |
Published: |
Animo Repository
2017
|
Subjects: | |
Online Access: | https://animorepository.dlsu.edu.ph/etd_bachelors/6759 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | De La Salle University |
Language: | English |
id |
oai:animorepository.dlsu.edu.ph:etd_bachelors-7403 |
---|---|
record_format |
eprints |
spelling |
oai:animorepository.dlsu.edu.ph:etd_bachelors-74032021-07-22T08:07:21Z Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital Almero, Glenn S. Costelo, Joseph Angelo P. Manubag, Alyssa Beatriz O. Zialcita, Stephanie A. Metro Manila is exposed to the Marikina Fault Valley system. The East and West Valley Faults, according to PHILVOCS, can generate earthquakes of magnitudes 6.2 to 7.2, respectively. According to recent studies, the effects of the ensuing ground motion can be disastrous. Thousands of people could die with damage to properties estimated to reach 1.8 to 2.3 trillion pesos. In a post-earthquake scenario, affected people depend on the quick recovery of lifetime systems such as hospitals and its supporting facilities. In order to ensure the functionality, resilience and serviceability of a medical facility after a large magnitude earthquake, assessment of the structural, non-structural, supporting facilities as well as non-fixed and movable equipment within the facility is necessary. In this regard, this research focuses on assessing the seismic risk of non-fixed and movable equipment inside the emergency room (ER), intensive care unit (ICU) and wards of the San Juan de Dios Educational Foundation, Inc. Hospital (SJDEFI). The primary motivation for this endeavor is that SJDEFI is a medical facility which is highly vulnerable considering it is one of the oldest hospitals in the country being constructed in 1578. The results of the probability of seismic hazard assessment (PSHA) revealed the following ground accelerations at the hospital site: (a) 10% probalility of exceedance in 50 years (MRI = 475 years) equal to 0.527g and, (b) 2% probability of exceedance in 50 years (MRI = 2,475 years) equal to 0.564g. After subjecting it to constant acceleration, the equipment's potential to overturn depends on the slenderness of the equipment since slender blocks has the potential to topple at lower accelerations. Rooms that are subjected to constant acceleration will experience significant damage when subjected to 0.5g to 0.6g acceleration and will be extensively damage at magnitudes of 0.8g or higher. 2017-01-01T08:00:00Z text https://animorepository.dlsu.edu.ph/etd_bachelors/6759 Bachelor's Theses English Animo Repository Earthquake hazard analysis--Philippines |
institution |
De La Salle University |
building |
De La Salle University Library |
continent |
Asia |
country |
Philippines Philippines |
content_provider |
De La Salle University Library |
collection |
DLSU Institutional Repository |
language |
English |
topic |
Earthquake hazard analysis--Philippines |
spellingShingle |
Earthquake hazard analysis--Philippines Almero, Glenn S. Costelo, Joseph Angelo P. Manubag, Alyssa Beatriz O. Zialcita, Stephanie A. Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital |
description |
Metro Manila is exposed to the Marikina Fault Valley system. The East and West Valley Faults, according to PHILVOCS, can generate earthquakes of magnitudes 6.2 to 7.2, respectively. According to recent studies, the effects of the ensuing ground motion can be disastrous. Thousands of people could die with damage to properties estimated to reach 1.8 to 2.3 trillion pesos.
In a post-earthquake scenario, affected people depend on the quick recovery of lifetime systems such as hospitals and its supporting facilities. In order to ensure the functionality, resilience and serviceability of a medical facility after a large magnitude earthquake, assessment of the structural, non-structural, supporting facilities as well as non-fixed and movable equipment within the facility is necessary. In this regard, this research focuses on assessing the seismic risk of non-fixed and movable equipment inside the emergency room (ER), intensive care unit (ICU) and wards of the San Juan de Dios Educational Foundation, Inc. Hospital (SJDEFI). The primary motivation for this endeavor is that SJDEFI is a medical facility which is highly vulnerable considering it is one of the oldest hospitals in the country being constructed in 1578.
The results of the probability of seismic hazard assessment (PSHA) revealed the following ground accelerations at the hospital site: (a) 10% probalility of exceedance in 50 years (MRI = 475 years) equal to 0.527g and, (b) 2% probability of exceedance in 50 years (MRI = 2,475 years) equal to 0.564g. After subjecting it to constant acceleration, the equipment's potential to overturn depends on the slenderness of the equipment since slender blocks has the potential to topple at lower accelerations. Rooms that are subjected to constant acceleration will experience significant damage when subjected to 0.5g to 0.6g acceleration and will be extensively damage at magnitudes of 0.8g or higher. |
format |
text |
author |
Almero, Glenn S. Costelo, Joseph Angelo P. Manubag, Alyssa Beatriz O. Zialcita, Stephanie A. |
author_facet |
Almero, Glenn S. Costelo, Joseph Angelo P. Manubag, Alyssa Beatriz O. Zialcita, Stephanie A. |
author_sort |
Almero, Glenn S. |
title |
Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital |
title_short |
Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital |
title_full |
Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital |
title_fullStr |
Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital |
title_full_unstemmed |
Proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: A case study: San Juan De Dios Hospital |
title_sort |
proposed methodology on seismic risk assessment of movable and non-fixed equipment inside a medical facility: a case study: san juan de dios hospital |
publisher |
Animo Repository |
publishDate |
2017 |
url |
https://animorepository.dlsu.edu.ph/etd_bachelors/6759 |
_version_ |
1712576639955632128 |