Evaluation of heat transfer coefficient in a fabricated double-pipe heat exchanger

This study aims to evaluate the heat transfer coefficient from a fabricated double-pipe heat exchanger. It also aims to determinate the performance of the fabricated heat exchanger through the data gathered during the experiment.In the fabricated double-pipe heat exchanger, counter current flow is e...

Full description

Saved in:
Bibliographic Details
Main Authors: Afable, Edward, Sia, Erwin Thomas
Format: text
Language:English
Published: Animo Repository 1994
Subjects:
Online Access:https://animorepository.dlsu.edu.ph/etd_bachelors/8559
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: De La Salle University
Language: English
id oai:animorepository.dlsu.edu.ph:etd_bachelors-9204
record_format eprints
spelling oai:animorepository.dlsu.edu.ph:etd_bachelors-92042021-08-23T07:06:20Z Evaluation of heat transfer coefficient in a fabricated double-pipe heat exchanger Afable, Edward Sia, Erwin Thomas This study aims to evaluate the heat transfer coefficient from a fabricated double-pipe heat exchanger. It also aims to determinate the performance of the fabricated heat exchanger through the data gathered during the experiment.In the fabricated double-pipe heat exchanger, counter current flow is employed. The fluid used is water which is both being heated and cooled. The hot water flows in the inside pipe while the cold water flows in the outside pipe. To monitor the temperatures of the heated and cooled water, thermocouples are used. A valve is used to control and vary the flowrate of the cold water.Through experiments performed on the fabricated double-pipe heat exchanger, the entering and leaving temperatures are noted both for the hot and cold water at specific flow rates. These are then substituted in the appropriate equations to determine both the theoretical and the actual heat transfer coefficient of the heat exchanger. The Wilson plot is also used to determine the experimental heat transfer coefficient. The theoretical and the actual heat transfer coefficients are then compared to evaluate the validity of the study. 1994-01-01T08:00:00Z text https://animorepository.dlsu.edu.ph/etd_bachelors/8559 Bachelor's Theses English Animo Repository Nusselt number Heat exchangers Heat pipes Pipe--Fluid dynamics Fluid dynamics Heat transfer coefficient
institution De La Salle University
building De La Salle University Library
continent Asia
country Philippines
Philippines
content_provider De La Salle University Library
collection DLSU Institutional Repository
language English
topic Nusselt number
Heat exchangers
Heat pipes
Pipe--Fluid dynamics
Fluid dynamics
Heat transfer coefficient
spellingShingle Nusselt number
Heat exchangers
Heat pipes
Pipe--Fluid dynamics
Fluid dynamics
Heat transfer coefficient
Afable, Edward
Sia, Erwin Thomas
Evaluation of heat transfer coefficient in a fabricated double-pipe heat exchanger
description This study aims to evaluate the heat transfer coefficient from a fabricated double-pipe heat exchanger. It also aims to determinate the performance of the fabricated heat exchanger through the data gathered during the experiment.In the fabricated double-pipe heat exchanger, counter current flow is employed. The fluid used is water which is both being heated and cooled. The hot water flows in the inside pipe while the cold water flows in the outside pipe. To monitor the temperatures of the heated and cooled water, thermocouples are used. A valve is used to control and vary the flowrate of the cold water.Through experiments performed on the fabricated double-pipe heat exchanger, the entering and leaving temperatures are noted both for the hot and cold water at specific flow rates. These are then substituted in the appropriate equations to determine both the theoretical and the actual heat transfer coefficient of the heat exchanger. The Wilson plot is also used to determine the experimental heat transfer coefficient. The theoretical and the actual heat transfer coefficients are then compared to evaluate the validity of the study.
format text
author Afable, Edward
Sia, Erwin Thomas
author_facet Afable, Edward
Sia, Erwin Thomas
author_sort Afable, Edward
title Evaluation of heat transfer coefficient in a fabricated double-pipe heat exchanger
title_short Evaluation of heat transfer coefficient in a fabricated double-pipe heat exchanger
title_full Evaluation of heat transfer coefficient in a fabricated double-pipe heat exchanger
title_fullStr Evaluation of heat transfer coefficient in a fabricated double-pipe heat exchanger
title_full_unstemmed Evaluation of heat transfer coefficient in a fabricated double-pipe heat exchanger
title_sort evaluation of heat transfer coefficient in a fabricated double-pipe heat exchanger
publisher Animo Repository
publishDate 1994
url https://animorepository.dlsu.edu.ph/etd_bachelors/8559
_version_ 1712576975921479680