A study of redox-active Nafion® modified electrodes for trace metal detection by anodic stripping voltammetry

Chemically modified electodes were fabricated by depositing tris (2,2-bipyridyl) ruthenium (II) dichloride hexahydrate doped Nafion® thin films on indium tin oxide coated glass substrates via the dip coating method. The Nafion and ruthenium complex concentrations were varied to optimize the sensitiv...

Full description

Saved in:
Bibliographic Details
Main Author: Guatato, Toni Beth F.
Format: text
Language:English
Published: Animo Repository 2014
Subjects:
Online Access:https://animorepository.dlsu.edu.ph/etd_masteral/4642
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: De La Salle University
Language: English
id oai:animorepository.dlsu.edu.ph:etd_masteral-11480
record_format eprints
spelling oai:animorepository.dlsu.edu.ph:etd_masteral-114802024-05-15T01:46:07Z A study of redox-active Nafion® modified electrodes for trace metal detection by anodic stripping voltammetry Guatato, Toni Beth F. Chemically modified electodes were fabricated by depositing tris (2,2-bipyridyl) ruthenium (II) dichloride hexahydrate doped Nafion® thin films on indium tin oxide coated glass substrates via the dip coating method. The Nafion and ruthenium complex concentrations were varied to optimize the sensitivity of the modified electrodes in detecting cadmium and lead. The surface morphology of the deposited film was characterized by scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX). The presence of the heavy metals in a 0.1 M NaCl supporting electrolyte solution was determined through the marked reduction potentials in the voltammograms obtained from the anodic stripping voltammetry (ASV) runs. The optimum Nafion volume concentration in the film was 0.4% which gave an average film thickness of 217.90 nm. The optimum mediator concentration is 5 mg per 1mL of Nafion. The minimum concentration detected for lead was 0.002 µg/mL and for cadmium was 0.9 µg/mL. The calibration curves obtained for both heavy metals show a linear relationship with an R2 value equal to 0.9514 for lead and 0.9832 for cadmium. 2014-01-01T08:00:00Z text https://animorepository.dlsu.edu.ph/etd_masteral/4642 Master's Theses English Animo Repository Electrodes
institution De La Salle University
building De La Salle University Library
continent Asia
country Philippines
Philippines
content_provider De La Salle University Library
collection DLSU Institutional Repository
language English
topic Electrodes
spellingShingle Electrodes
Guatato, Toni Beth F.
A study of redox-active Nafion® modified electrodes for trace metal detection by anodic stripping voltammetry
description Chemically modified electodes were fabricated by depositing tris (2,2-bipyridyl) ruthenium (II) dichloride hexahydrate doped Nafion® thin films on indium tin oxide coated glass substrates via the dip coating method. The Nafion and ruthenium complex concentrations were varied to optimize the sensitivity of the modified electrodes in detecting cadmium and lead. The surface morphology of the deposited film was characterized by scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX). The presence of the heavy metals in a 0.1 M NaCl supporting electrolyte solution was determined through the marked reduction potentials in the voltammograms obtained from the anodic stripping voltammetry (ASV) runs. The optimum Nafion volume concentration in the film was 0.4% which gave an average film thickness of 217.90 nm. The optimum mediator concentration is 5 mg per 1mL of Nafion. The minimum concentration detected for lead was 0.002 µg/mL and for cadmium was 0.9 µg/mL. The calibration curves obtained for both heavy metals show a linear relationship with an R2 value equal to 0.9514 for lead and 0.9832 for cadmium.
format text
author Guatato, Toni Beth F.
author_facet Guatato, Toni Beth F.
author_sort Guatato, Toni Beth F.
title A study of redox-active Nafion® modified electrodes for trace metal detection by anodic stripping voltammetry
title_short A study of redox-active Nafion® modified electrodes for trace metal detection by anodic stripping voltammetry
title_full A study of redox-active Nafion® modified electrodes for trace metal detection by anodic stripping voltammetry
title_fullStr A study of redox-active Nafion® modified electrodes for trace metal detection by anodic stripping voltammetry
title_full_unstemmed A study of redox-active Nafion® modified electrodes for trace metal detection by anodic stripping voltammetry
title_sort study of redox-active nafion® modified electrodes for trace metal detection by anodic stripping voltammetry
publisher Animo Repository
publishDate 2014
url https://animorepository.dlsu.edu.ph/etd_masteral/4642
_version_ 1800918834593398784