Determination of dragout rates of solderon acid in the plating cell by tank analysis method

Staining of leadframes is one of the problems encountered in the Solder plate process (Tin-Lead Plating Process). It occurs when the spray rinse water and neutralizer solutions are acidic. Experiments on the determination of dragout rate of Solderon acid in the plating cell and the effect of dragout...

Full description

Saved in:
Bibliographic Details
Main Author: Antonio, Bernadeth S.
Format: text
Language:English
Published: Animo Repository 1997
Subjects:
Online Access:https://animorepository.dlsu.edu.ph/etd_masteral/1823
https://animorepository.dlsu.edu.ph/cgi/viewcontent.cgi?article=8661&context=etd_masteral
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: De La Salle University
Language: English
id oai:animorepository.dlsu.edu.ph:etd_masteral-8661
record_format eprints
spelling oai:animorepository.dlsu.edu.ph:etd_masteral-86612022-03-30T03:19:57Z Determination of dragout rates of solderon acid in the plating cell by tank analysis method Antonio, Bernadeth S. Staining of leadframes is one of the problems encountered in the Solder plate process (Tin-Lead Plating Process). It occurs when the spray rinse water and neutralizer solutions are acidic. Experiments on the determination of dragout rate of Solderon acid in the plating cell and the effect of dragout of Solderon acid in the pH of spray rinse water and neutralizer were conducted. Dragout is a liquid that is carried along by the material being plated as it transferred from one cell to another. The water from the spray rinse sump tank is originally a re-circulating process and the water supply comes from the used water of hot de-ionized rinse. With this set up, it was found out that the dragout of Solderon acid in the plating cell made the spray rinse water and neutralizer solutions acidic which led to the staining of the leadframes.Re-piping was then proposed to eliminate or minimize staining problems. Experiments on the effect of re-piping on the pH of the spray rinse and neutralizer were also conducted. Data shows that after re-piping, the spray rinse water and neutralizer had maintained their basic levels. As such, re-piping as a means of eliminating or minimizing the staining problem in the leadframes is effective. 1997-05-01T07:00:00Z text application/pdf https://animorepository.dlsu.edu.ph/etd_masteral/1823 https://animorepository.dlsu.edu.ph/cgi/viewcontent.cgi?article=8661&context=etd_masteral Master's Theses English Animo Repository Solder and soldering Acids Lead plating Semiconductor industry Tanks Chemical Engineering
institution De La Salle University
building De La Salle University Library
continent Asia
country Philippines
Philippines
content_provider De La Salle University Library
collection DLSU Institutional Repository
language English
topic Solder and soldering
Acids
Lead plating
Semiconductor industry
Tanks
Chemical Engineering
spellingShingle Solder and soldering
Acids
Lead plating
Semiconductor industry
Tanks
Chemical Engineering
Antonio, Bernadeth S.
Determination of dragout rates of solderon acid in the plating cell by tank analysis method
description Staining of leadframes is one of the problems encountered in the Solder plate process (Tin-Lead Plating Process). It occurs when the spray rinse water and neutralizer solutions are acidic. Experiments on the determination of dragout rate of Solderon acid in the plating cell and the effect of dragout of Solderon acid in the pH of spray rinse water and neutralizer were conducted. Dragout is a liquid that is carried along by the material being plated as it transferred from one cell to another. The water from the spray rinse sump tank is originally a re-circulating process and the water supply comes from the used water of hot de-ionized rinse. With this set up, it was found out that the dragout of Solderon acid in the plating cell made the spray rinse water and neutralizer solutions acidic which led to the staining of the leadframes.Re-piping was then proposed to eliminate or minimize staining problems. Experiments on the effect of re-piping on the pH of the spray rinse and neutralizer were also conducted. Data shows that after re-piping, the spray rinse water and neutralizer had maintained their basic levels. As such, re-piping as a means of eliminating or minimizing the staining problem in the leadframes is effective.
format text
author Antonio, Bernadeth S.
author_facet Antonio, Bernadeth S.
author_sort Antonio, Bernadeth S.
title Determination of dragout rates of solderon acid in the plating cell by tank analysis method
title_short Determination of dragout rates of solderon acid in the plating cell by tank analysis method
title_full Determination of dragout rates of solderon acid in the plating cell by tank analysis method
title_fullStr Determination of dragout rates of solderon acid in the plating cell by tank analysis method
title_full_unstemmed Determination of dragout rates of solderon acid in the plating cell by tank analysis method
title_sort determination of dragout rates of solderon acid in the plating cell by tank analysis method
publisher Animo Repository
publishDate 1997
url https://animorepository.dlsu.edu.ph/etd_masteral/1823
https://animorepository.dlsu.edu.ph/cgi/viewcontent.cgi?article=8661&context=etd_masteral
_version_ 1729800016113958912