Measuring or testing activity is useful only if the results of measurements are reliable, sufficiently accurate and with a known degree of uncertainty. The measuring and test equipment must have the desired level of accuracy and consistency when operated under condition of actual usage, and that it...
Saved in:
Main Author: | |
---|---|
Format: | text |
Language: | English |
Published: |
Animo Repository
1998
|
Subjects: | |
Online Access: | https://animorepository.dlsu.edu.ph/etd_masteral/1946 https://animorepository.dlsu.edu.ph/cgi/viewcontent.cgi?article=8784&context=etd_masteral |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | De La Salle University |
Language: | English |
id |
oai:animorepository.dlsu.edu.ph:etd_masteral-8784 |
---|---|
record_format |
eprints |
spelling |
oai:animorepository.dlsu.edu.ph:etd_masteral-87842022-03-30T07:13:47Z Equipment calibration and maintenance system of testing laboratory for ISO/IEC guide 25 accreditation Tulay, Claire T. Measuring or testing activity is useful only if the results of measurements are reliable, sufficiently accurate and with a known degree of uncertainty. The measuring and test equipment must have the desired level of accuracy and consistency when operated under condition of actual usage, and that it is usable only when it is functioning to the specified accuracy level and when it has been properly calibrated. Knowing the significance of calibration, Petron Laboratory of Pandacan Terminal aims to be ISO/IEC Guide 25 certified, to ensure that all equipment are properly calibrated and well maintained to generate better quality product. To fulfill the requirements for ISO/IEC G 25, the author developed the calibration and maintenance system of the Technical Section and Instrumentation Section of Petron Laboratory. The developed system consisted of calibration procedural details, for both in-house and bulk-plant equipment, equipment calibration working instructions, equipment operating procedure, equipment maintenance procedure, and standard formats of associated documents. The author also calibrates the hydrometer and thermometer of Petron bulk-plant for ISO 9000 accreditation. 1998-05-07T07:00:00Z text application/pdf https://animorepository.dlsu.edu.ph/etd_masteral/1946 https://animorepository.dlsu.edu.ph/cgi/viewcontent.cgi?article=8784&context=etd_masteral Master's Theses English Animo Repository Calibration Physical measurements Plant maintenance Industrial equipment -- Maintenance and repair Standardization Chemical Engineering |
institution |
De La Salle University |
building |
De La Salle University Library |
continent |
Asia |
country |
Philippines Philippines |
content_provider |
De La Salle University Library |
collection |
DLSU Institutional Repository |
language |
English |
topic |
Calibration Physical measurements Plant maintenance Industrial equipment -- Maintenance and repair Standardization Chemical Engineering |
spellingShingle |
Calibration Physical measurements Plant maintenance Industrial equipment -- Maintenance and repair Standardization Chemical Engineering Tulay, Claire T. Equipment calibration and maintenance system of testing laboratory for ISO/IEC guide 25 accreditation |
description |
Measuring or testing activity is useful only if the results of measurements are reliable, sufficiently accurate and with a known degree of uncertainty. The measuring and test equipment must have the desired level of accuracy and consistency when operated under condition of actual usage, and that it is usable only when it is functioning to the specified accuracy level and when it has been properly calibrated. Knowing the significance of calibration, Petron Laboratory of Pandacan Terminal aims to be ISO/IEC Guide 25 certified, to ensure that all equipment are properly calibrated and well maintained to generate better quality product. To fulfill the requirements for ISO/IEC G 25, the author developed the calibration and maintenance system of the Technical Section and Instrumentation Section of Petron Laboratory. The developed system consisted of calibration procedural details, for both in-house and bulk-plant equipment, equipment calibration working instructions, equipment operating procedure, equipment maintenance procedure, and standard formats of associated documents. The author also calibrates the hydrometer and thermometer of Petron bulk-plant for ISO 9000 accreditation. |
format |
text |
author |
Tulay, Claire T. |
author_facet |
Tulay, Claire T. |
author_sort |
Tulay, Claire T. |
title |
Equipment calibration and maintenance system of testing laboratory for ISO/IEC guide 25 accreditation |
title_short |
Equipment calibration and maintenance system of testing laboratory for ISO/IEC guide 25 accreditation |
title_full |
Equipment calibration and maintenance system of testing laboratory for ISO/IEC guide 25 accreditation |
title_fullStr |
Equipment calibration and maintenance system of testing laboratory for ISO/IEC guide 25 accreditation |
title_full_unstemmed |
Equipment calibration and maintenance system of testing laboratory for ISO/IEC guide 25 accreditation |
title_sort |
equipment calibration and maintenance system of testing laboratory for iso/iec guide 25 accreditation |
publisher |
Animo Repository |
publishDate |
1998 |
url |
https://animorepository.dlsu.edu.ph/etd_masteral/1946 https://animorepository.dlsu.edu.ph/cgi/viewcontent.cgi?article=8784&context=etd_masteral |
_version_ |
1729800017278926848 |