Non-invasive blood glucose monitoring using near-infrared LED spectrophotometry

Diabetes is an incurable disease that was recorded to affect 9% of the world population in 2019. Research shows that the numbers have been continuously growing and are projected to increase by 45% in 2045 [20]. Part of the treatment for diabetes is self-administering medication which is dependent on...

Full description

Saved in:
Bibliographic Details
Main Authors: Vidal, Mary Celina C., Yuchingtat, Rafael D.
Format: text
Language:English
Published: Animo Repository 2022
Subjects:
Online Access:https://animorepository.dlsu.edu.ph/etdb_physics/2
https://animorepository.dlsu.edu.ph/cgi/viewcontent.cgi?article=1015&context=etdb_physics
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: De La Salle University
Language: English
id oai:animorepository.dlsu.edu.ph:etdb_physics-1015
record_format eprints
spelling oai:animorepository.dlsu.edu.ph:etdb_physics-10152023-01-11T05:21:50Z Non-invasive blood glucose monitoring using near-infrared LED spectrophotometry Vidal, Mary Celina C. Yuchingtat, Rafael D. Diabetes is an incurable disease that was recorded to affect 9% of the world population in 2019. Research shows that the numbers have been continuously growing and are projected to increase by 45% in 2045 [20]. Part of the treatment for diabetes is self-administering medication which is dependent on the monitoring of one’s blood glucose levels. Most blood glucose monitoring devices require the pricking of one’s finger, which is inconvenient and painful given that this must be done several times a day. This study tackles a non-invasive approach to monitoring blood glucose using Near-Infrared Light Emitting Diodes (NIR LED) spectrophotometry. A device was made using two NIR LEDs as transmitter and receiver. Blood glucose control solutions in glass cuvettes that acted as phantom fingers were tested to determine glucose concentration. The receiver LED’s voltage was collected and used to compute the absorbance of the samples via Beer-Lambert Law. The aim was to correlate the voltage response with glucose levels. Using simple linear regression analysis and pearson correlation, a very strong negative linear relationship was found between the voltage of the receiver LED and the absorbance of the samples. A calibration curve equation for the expected glucose concentration of the samples was derived from the best fit line of the scatter plot of the voltage versus the reference glucose concentration. A t-test comparing the computed expected glucose concentration and the reference values measured using a glucose meter revealed that there is a significant difference between the two variables. To determine the clinical accuracy of the device, a Clarke Error Grid Analysis was also used which revealed that only 50 of the 90 data points from the experiment were found to be within the zone of acceptance. 2022-07-18T07:00:00Z text application/pdf https://animorepository.dlsu.edu.ph/etdb_physics/2 https://animorepository.dlsu.edu.ph/cgi/viewcontent.cgi?article=1015&context=etdb_physics Physics Bachelor's Theses English Animo Repository Blood glucose monitoring Near infrared spectroscopy Physics
institution De La Salle University
building De La Salle University Library
continent Asia
country Philippines
Philippines
content_provider De La Salle University Library
collection DLSU Institutional Repository
language English
topic Blood glucose monitoring
Near infrared spectroscopy
Physics
spellingShingle Blood glucose monitoring
Near infrared spectroscopy
Physics
Vidal, Mary Celina C.
Yuchingtat, Rafael D.
Non-invasive blood glucose monitoring using near-infrared LED spectrophotometry
description Diabetes is an incurable disease that was recorded to affect 9% of the world population in 2019. Research shows that the numbers have been continuously growing and are projected to increase by 45% in 2045 [20]. Part of the treatment for diabetes is self-administering medication which is dependent on the monitoring of one’s blood glucose levels. Most blood glucose monitoring devices require the pricking of one’s finger, which is inconvenient and painful given that this must be done several times a day. This study tackles a non-invasive approach to monitoring blood glucose using Near-Infrared Light Emitting Diodes (NIR LED) spectrophotometry. A device was made using two NIR LEDs as transmitter and receiver. Blood glucose control solutions in glass cuvettes that acted as phantom fingers were tested to determine glucose concentration. The receiver LED’s voltage was collected and used to compute the absorbance of the samples via Beer-Lambert Law. The aim was to correlate the voltage response with glucose levels. Using simple linear regression analysis and pearson correlation, a very strong negative linear relationship was found between the voltage of the receiver LED and the absorbance of the samples. A calibration curve equation for the expected glucose concentration of the samples was derived from the best fit line of the scatter plot of the voltage versus the reference glucose concentration. A t-test comparing the computed expected glucose concentration and the reference values measured using a glucose meter revealed that there is a significant difference between the two variables. To determine the clinical accuracy of the device, a Clarke Error Grid Analysis was also used which revealed that only 50 of the 90 data points from the experiment were found to be within the zone of acceptance.
format text
author Vidal, Mary Celina C.
Yuchingtat, Rafael D.
author_facet Vidal, Mary Celina C.
Yuchingtat, Rafael D.
author_sort Vidal, Mary Celina C.
title Non-invasive blood glucose monitoring using near-infrared LED spectrophotometry
title_short Non-invasive blood glucose monitoring using near-infrared LED spectrophotometry
title_full Non-invasive blood glucose monitoring using near-infrared LED spectrophotometry
title_fullStr Non-invasive blood glucose monitoring using near-infrared LED spectrophotometry
title_full_unstemmed Non-invasive blood glucose monitoring using near-infrared LED spectrophotometry
title_sort non-invasive blood glucose monitoring using near-infrared led spectrophotometry
publisher Animo Repository
publishDate 2022
url https://animorepository.dlsu.edu.ph/etdb_physics/2
https://animorepository.dlsu.edu.ph/cgi/viewcontent.cgi?article=1015&context=etdb_physics
_version_ 1754713747632422912