Rapid screening and evaluation of existing buildings

Two rapid assessment procedures will be discussed in this paper - the "Pre-Earthquake Evaluation of Existing Buildings", and the "Post-Earthquake Evaluation of Existing Buildings." The first evaluation procedure is using the standard forms found in the Handbook developed by the A...

Full description

Saved in:
Bibliographic Details
Main Author: Manalo, Joseph Ramil I.
Format: text
Published: Animo Repository 2007
Subjects:
Online Access:https://animorepository.dlsu.edu.ph/faculty_research/12270
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: De La Salle University
id oai:animorepository.dlsu.edu.ph:faculty_research-10384
record_format eprints
spelling oai:animorepository.dlsu.edu.ph:faculty_research-103842023-04-01T07:34:25Z Rapid screening and evaluation of existing buildings Manalo, Joseph Ramil I. Two rapid assessment procedures will be discussed in this paper - the "Pre-Earthquake Evaluation of Existing Buildings", and the "Post-Earthquake Evaluation of Existing Buildings." The first evaluation procedure is using the standard forms found in the Handbook developed by the Applied Technology Council, with funding from the Federal Management Agency (FEMA). The report submitted by ATC to FEMA is known as "Rapid Visual Screening of Buildings for Potential Seismic Hazards: A Handbook".The other assessment procedure is by the use of the "Rapid Evaluation Safety Assessment Form". Said form was adopted by the ASEP-PICE DQRP Program. This program is a post earthquake damaged assessment program of the Association of Structural Engineers of the Philippines, the Philippine Institute of Civil Engineers, and the Office of the Civil Defense - National Disaster Coordinating Council.An actual sample on the use of this form is presented to give readers a full account on how these forms are accomplished as well as how data are interpreted and finally given the assessment required. This assessment of structural integrity of the structure will help us decide on which of these structures will be needing immediate attention in terms of repair or retrofitting or which ones may be scheduled later for possible more detailed assessment.Further, excerpts from the report of the DQRP Team composing of PICE and ASEP Volunteer inspectors during the conducted rapid evaluation of buildings affected by the March 6, 2002 earthquake is presented. This report covers the extent of damage caused by the magnitude 6.8 earthquake that hit Southern Mindanao at 5:15 in the morning. The author is a member of this team that performed such assessment under the Disaster Quick Response Program (DQRP) 2007-02-21T08:00:00Z text https://animorepository.dlsu.edu.ph/faculty_research/12270 Faculty Research Work Animo Repository Civil Engineering
institution De La Salle University
building De La Salle University Library
continent Asia
country Philippines
Philippines
content_provider De La Salle University Library
collection DLSU Institutional Repository
topic Civil Engineering
spellingShingle Civil Engineering
Manalo, Joseph Ramil I.
Rapid screening and evaluation of existing buildings
description Two rapid assessment procedures will be discussed in this paper - the "Pre-Earthquake Evaluation of Existing Buildings", and the "Post-Earthquake Evaluation of Existing Buildings." The first evaluation procedure is using the standard forms found in the Handbook developed by the Applied Technology Council, with funding from the Federal Management Agency (FEMA). The report submitted by ATC to FEMA is known as "Rapid Visual Screening of Buildings for Potential Seismic Hazards: A Handbook".The other assessment procedure is by the use of the "Rapid Evaluation Safety Assessment Form". Said form was adopted by the ASEP-PICE DQRP Program. This program is a post earthquake damaged assessment program of the Association of Structural Engineers of the Philippines, the Philippine Institute of Civil Engineers, and the Office of the Civil Defense - National Disaster Coordinating Council.An actual sample on the use of this form is presented to give readers a full account on how these forms are accomplished as well as how data are interpreted and finally given the assessment required. This assessment of structural integrity of the structure will help us decide on which of these structures will be needing immediate attention in terms of repair or retrofitting or which ones may be scheduled later for possible more detailed assessment.Further, excerpts from the report of the DQRP Team composing of PICE and ASEP Volunteer inspectors during the conducted rapid evaluation of buildings affected by the March 6, 2002 earthquake is presented. This report covers the extent of damage caused by the magnitude 6.8 earthquake that hit Southern Mindanao at 5:15 in the morning. The author is a member of this team that performed such assessment under the Disaster Quick Response Program (DQRP)
format text
author Manalo, Joseph Ramil I.
author_facet Manalo, Joseph Ramil I.
author_sort Manalo, Joseph Ramil I.
title Rapid screening and evaluation of existing buildings
title_short Rapid screening and evaluation of existing buildings
title_full Rapid screening and evaluation of existing buildings
title_fullStr Rapid screening and evaluation of existing buildings
title_full_unstemmed Rapid screening and evaluation of existing buildings
title_sort rapid screening and evaluation of existing buildings
publisher Animo Repository
publishDate 2007
url https://animorepository.dlsu.edu.ph/faculty_research/12270
_version_ 1800918957960462336