Dechlorination of polychlorinated biphenyls (PCBs) in water matrix using UV/H2O2

This study presents the results of GC-mass spectrophotometric analysis of the formation of reaction intermediates or products during the degradation of polychlorinated biphenyls (PCBS) using the UV/H2O2 system. Simulated PCB contaminated water solution was subjected to irradiation with 10 watt, 254...

Full description

Saved in:
Bibliographic Details
Main Authors: Centeno, Carmel R., Tolentino, Elaine Nicolas, Abella, Leonila C., Gallardo, Susan M.
Format: text
Published: Animo Repository 2005
Subjects:
Online Access:https://animorepository.dlsu.edu.ph/faculty_research/13356
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: De La Salle University
id oai:animorepository.dlsu.edu.ph:faculty_research-13797
record_format eprints
spelling oai:animorepository.dlsu.edu.ph:faculty_research-137972024-11-11T02:22:07Z Dechlorination of polychlorinated biphenyls (PCBs) in water matrix using UV/H2O2 Centeno, Carmel R. Tolentino, Elaine Nicolas Abella, Leonila C. Gallardo, Susan M. This study presents the results of GC-mass spectrophotometric analysis of the formation of reaction intermediates or products during the degradation of polychlorinated biphenyls (PCBS) using the UV/H2O2 system. Simulated PCB contaminated water solution was subjected to irradiation with 10 watt, 254 nm wavelength UV lamp in a batch tubular reactor. Ratio of oxidant to PCBs (in terms of Aroclor 1260) was based on 2,500 µL H₂O₂ is to 40ppm PCB. Samples were extracted from the matrix by solid-phase extraction (SPE) method using C18 cartridges with hexane and ethyl acetate as solvents. Samples were analyzed using Gas Chromatography-Electron Capture Detector System (GC-ECD) to determine the concentrations of PCBs in the samples and pH was monitored every sampling time. The analysis of chloride (CI) ion concentration in the samples was done using Argentometric titration. Gas Chromatography-Mass Spectroscopy (GC-MS) analysis showed that Aroclor 1260 contained highly chlorinated biphenyls penta-, hexa-, hepta-, and octachlorobiphenyls. Determination of reaction intermediates and products was also carried out. Since a decrease in pH in the early stages of degradation was observed, dechlorination must have been the main mechanism during the first few minutes of the reaction. Analysis of inorganic chloride ions concentration verified this observation. GC-MS results also show that the oils and waxes containing the PCBs were also degraded but PCB degradation was favored during the first few minutes of the reaction. 2005-04-01T08:00:00Z text https://animorepository.dlsu.edu.ph/faculty_research/13356 Faculty Research Work Animo Repository Dechlorination Polychlorinated biphenyls Chemistry
institution De La Salle University
building De La Salle University Library
continent Asia
country Philippines
Philippines
content_provider De La Salle University Library
collection DLSU Institutional Repository
topic Dechlorination
Polychlorinated biphenyls
Chemistry
spellingShingle Dechlorination
Polychlorinated biphenyls
Chemistry
Centeno, Carmel R.
Tolentino, Elaine Nicolas
Abella, Leonila C.
Gallardo, Susan M.
Dechlorination of polychlorinated biphenyls (PCBs) in water matrix using UV/H2O2
description This study presents the results of GC-mass spectrophotometric analysis of the formation of reaction intermediates or products during the degradation of polychlorinated biphenyls (PCBS) using the UV/H2O2 system. Simulated PCB contaminated water solution was subjected to irradiation with 10 watt, 254 nm wavelength UV lamp in a batch tubular reactor. Ratio of oxidant to PCBs (in terms of Aroclor 1260) was based on 2,500 µL H₂O₂ is to 40ppm PCB. Samples were extracted from the matrix by solid-phase extraction (SPE) method using C18 cartridges with hexane and ethyl acetate as solvents. Samples were analyzed using Gas Chromatography-Electron Capture Detector System (GC-ECD) to determine the concentrations of PCBs in the samples and pH was monitored every sampling time. The analysis of chloride (CI) ion concentration in the samples was done using Argentometric titration. Gas Chromatography-Mass Spectroscopy (GC-MS) analysis showed that Aroclor 1260 contained highly chlorinated biphenyls penta-, hexa-, hepta-, and octachlorobiphenyls. Determination of reaction intermediates and products was also carried out. Since a decrease in pH in the early stages of degradation was observed, dechlorination must have been the main mechanism during the first few minutes of the reaction. Analysis of inorganic chloride ions concentration verified this observation. GC-MS results also show that the oils and waxes containing the PCBs were also degraded but PCB degradation was favored during the first few minutes of the reaction.
format text
author Centeno, Carmel R.
Tolentino, Elaine Nicolas
Abella, Leonila C.
Gallardo, Susan M.
author_facet Centeno, Carmel R.
Tolentino, Elaine Nicolas
Abella, Leonila C.
Gallardo, Susan M.
author_sort Centeno, Carmel R.
title Dechlorination of polychlorinated biphenyls (PCBs) in water matrix using UV/H2O2
title_short Dechlorination of polychlorinated biphenyls (PCBs) in water matrix using UV/H2O2
title_full Dechlorination of polychlorinated biphenyls (PCBs) in water matrix using UV/H2O2
title_fullStr Dechlorination of polychlorinated biphenyls (PCBs) in water matrix using UV/H2O2
title_full_unstemmed Dechlorination of polychlorinated biphenyls (PCBs) in water matrix using UV/H2O2
title_sort dechlorination of polychlorinated biphenyls (pcbs) in water matrix using uv/h2o2
publisher Animo Repository
publishDate 2005
url https://animorepository.dlsu.edu.ph/faculty_research/13356
_version_ 1816861338797867008