Interior air quality studies of air-conditioned surface transportation in Manila

This paper presents the completed and on-going studies of air-conditioned surface transportation in Manila which are done at the Mechanical Engineering Department of De La Salle University. The recently completed studies include : assessment of chemical contaminants and biological contaminants in ai...

Full description

Saved in:
Bibliographic Details
Main Author: Belino, Manuel C.
Format: text
Published: Animo Repository 2006
Subjects:
Online Access:https://animorepository.dlsu.edu.ph/faculty_research/570
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: De La Salle University
id oai:animorepository.dlsu.edu.ph:faculty_research-1569
record_format eprints
spelling oai:animorepository.dlsu.edu.ph:faculty_research-15692022-01-06T05:36:44Z Interior air quality studies of air-conditioned surface transportation in Manila Belino, Manuel C. This paper presents the completed and on-going studies of air-conditioned surface transportation in Manila which are done at the Mechanical Engineering Department of De La Salle University. The recently completed studies include : assessment of chemical contaminants and biological contaminants in air-conditioned urban buses and installation of a positive pressure fan to maintain good interior quality in air-conditioned urban buses. The on-going study deals with the interior air quality of ship cabins. These studies assessed the biological contaminants, particulate matter, chemical contaminants such as carbon dioxide, carbon monoxide, sulfur oxide, nitrogen oxide, and volatile organic compounds such as benzene and toluene. Surveys were done to relate the health problems experienced by the occupants with the commonly contracted diseases/illnesses due to poor air quality. These studies also include some form of interventions to reduce the concentration of chemical/biological contaminants like the use of an ultra-violet light and installation of a positive pressure fan. Results of these studies have shown the presence of some contaminants in concentration that exceeded the maximum allowable value found in the indoor air quality standard. The interventions used in the study prove to be effective in reducing the contaminants. Health problems experienced by the occupants and the diseases/illnesses caused by the contaminants present were related. 2006-12-01T08:00:00Z text https://animorepository.dlsu.edu.ph/faculty_research/570 Faculty Research Work Animo Repository Indoor air quality Air—Pollution Motor vehicles—Pollution control devices Environmental Engineering Mechanical Engineering
institution De La Salle University
building De La Salle University Library
continent Asia
country Philippines
Philippines
content_provider De La Salle University Library
collection DLSU Institutional Repository
topic Indoor air quality
Air—Pollution
Motor vehicles—Pollution control devices
Environmental Engineering
Mechanical Engineering
spellingShingle Indoor air quality
Air—Pollution
Motor vehicles—Pollution control devices
Environmental Engineering
Mechanical Engineering
Belino, Manuel C.
Interior air quality studies of air-conditioned surface transportation in Manila
description This paper presents the completed and on-going studies of air-conditioned surface transportation in Manila which are done at the Mechanical Engineering Department of De La Salle University. The recently completed studies include : assessment of chemical contaminants and biological contaminants in air-conditioned urban buses and installation of a positive pressure fan to maintain good interior quality in air-conditioned urban buses. The on-going study deals with the interior air quality of ship cabins. These studies assessed the biological contaminants, particulate matter, chemical contaminants such as carbon dioxide, carbon monoxide, sulfur oxide, nitrogen oxide, and volatile organic compounds such as benzene and toluene. Surveys were done to relate the health problems experienced by the occupants with the commonly contracted diseases/illnesses due to poor air quality. These studies also include some form of interventions to reduce the concentration of chemical/biological contaminants like the use of an ultra-violet light and installation of a positive pressure fan. Results of these studies have shown the presence of some contaminants in concentration that exceeded the maximum allowable value found in the indoor air quality standard. The interventions used in the study prove to be effective in reducing the contaminants. Health problems experienced by the occupants and the diseases/illnesses caused by the contaminants present were related.
format text
author Belino, Manuel C.
author_facet Belino, Manuel C.
author_sort Belino, Manuel C.
title Interior air quality studies of air-conditioned surface transportation in Manila
title_short Interior air quality studies of air-conditioned surface transportation in Manila
title_full Interior air quality studies of air-conditioned surface transportation in Manila
title_fullStr Interior air quality studies of air-conditioned surface transportation in Manila
title_full_unstemmed Interior air quality studies of air-conditioned surface transportation in Manila
title_sort interior air quality studies of air-conditioned surface transportation in manila
publisher Animo Repository
publishDate 2006
url https://animorepository.dlsu.edu.ph/faculty_research/570
_version_ 1722366372721197056