Electromagnetic shielding to improve EMC of a robotic medical device
© 2019 Author(s). Electromagnetic compatibility has been part of both R&D and product development for a long time. However, only a hand-full of these projects undergo the test for compliance. These are usually products from big companies or those sold in areas where certain requirements are need...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | text |
Published: |
Animo Repository
2019
|
Online Access: | https://animorepository.dlsu.edu.ph/faculty_research/1072 https://animorepository.dlsu.edu.ph/context/faculty_research/article/2071/type/native/viewcontent |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | De La Salle University |
id |
oai:animorepository.dlsu.edu.ph:faculty_research-2071 |
---|---|
record_format |
eprints |
spelling |
oai:animorepository.dlsu.edu.ph:faculty_research-20712022-12-20T11:19:02Z Electromagnetic shielding to improve EMC of a robotic medical device Dupo, Voltaire B. Belista, Francis De Sagun, Vernicka Bugtai, Nilo Baldovino, Rennan G. Abad, Alexander C. Dungao, Jade © 2019 Author(s). Electromagnetic compatibility has been part of both R&D and product development for a long time. However, only a hand-full of these projects undergo the test for compliance. These are usually products from big companies or those sold in areas where certain requirements are needed to enter the market. In the case of medical devices, the Comité International Spécial des Perturbations Radioélectriques (CISPR) standard, is used in certain countries. This research revolves around the steps taken to comply with the CISPR 11 and CISPR 22 standards. Different methods and materials were used in combinations and are tested to observe the improvement in bringing the device to comply with electromagnetic safety standards. Moreover, this research would aid others who are trying to design their own medical device to fruition. Thus, give basis for them to try and experiment with their own set of radiation shielding. 2019-12-10T08:00:00Z text text/html https://animorepository.dlsu.edu.ph/faculty_research/1072 https://animorepository.dlsu.edu.ph/context/faculty_research/article/2071/type/native/viewcontent Faculty Research Work Animo Repository |
institution |
De La Salle University |
building |
De La Salle University Library |
continent |
Asia |
country |
Philippines Philippines |
content_provider |
De La Salle University Library |
collection |
DLSU Institutional Repository |
description |
© 2019 Author(s). Electromagnetic compatibility has been part of both R&D and product development for a long time. However, only a hand-full of these projects undergo the test for compliance. These are usually products from big companies or those sold in areas where certain requirements are needed to enter the market. In the case of medical devices, the Comité International Spécial des Perturbations Radioélectriques (CISPR) standard, is used in certain countries. This research revolves around the steps taken to comply with the CISPR 11 and CISPR 22 standards. Different methods and materials were used in combinations and are tested to observe the improvement in bringing the device to comply with electromagnetic safety standards. Moreover, this research would aid others who are trying to design their own medical device to fruition. Thus, give basis for them to try and experiment with their own set of radiation shielding. |
format |
text |
author |
Dupo, Voltaire B. Belista, Francis De Sagun, Vernicka Bugtai, Nilo Baldovino, Rennan G. Abad, Alexander C. Dungao, Jade |
spellingShingle |
Dupo, Voltaire B. Belista, Francis De Sagun, Vernicka Bugtai, Nilo Baldovino, Rennan G. Abad, Alexander C. Dungao, Jade Electromagnetic shielding to improve EMC of a robotic medical device |
author_facet |
Dupo, Voltaire B. Belista, Francis De Sagun, Vernicka Bugtai, Nilo Baldovino, Rennan G. Abad, Alexander C. Dungao, Jade |
author_sort |
Dupo, Voltaire B. |
title |
Electromagnetic shielding to improve EMC of a robotic medical device |
title_short |
Electromagnetic shielding to improve EMC of a robotic medical device |
title_full |
Electromagnetic shielding to improve EMC of a robotic medical device |
title_fullStr |
Electromagnetic shielding to improve EMC of a robotic medical device |
title_full_unstemmed |
Electromagnetic shielding to improve EMC of a robotic medical device |
title_sort |
electromagnetic shielding to improve emc of a robotic medical device |
publisher |
Animo Repository |
publishDate |
2019 |
url |
https://animorepository.dlsu.edu.ph/faculty_research/1072 https://animorepository.dlsu.edu.ph/context/faculty_research/article/2071/type/native/viewcontent |
_version_ |
1753806458303021056 |