Ultimate confined compressive strength of carbon fiber-reinforced circular and rectangular concrete column

Retrofitting circular and rectangular concrete columns with Carbon Fiber Reinforced Polymer (CFRP) has been proven to be a method of increasing the ultimate confined compressive strength fcc′. The present study uses a hybrid of Analytic Hierarchy Process (AHP) and Backpropagation Artificial Neural N...

Full description

Saved in:
Bibliographic Details
Main Authors: Ongpeng, Jason Maximino C., Lecciones, Isabel Nicole C., Garduque, Jasmine Anne, Buera, Daniel Joshua
Format: text
Published: Animo Repository 2020
Subjects:
Online Access:https://animorepository.dlsu.edu.ph/faculty_research/1653
https://animorepository.dlsu.edu.ph/context/faculty_research/article/2652/type/native/viewcontent
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: De La Salle University
id oai:animorepository.dlsu.edu.ph:faculty_research-2652
record_format eprints
spelling oai:animorepository.dlsu.edu.ph:faculty_research-26522023-03-02T07:40:43Z Ultimate confined compressive strength of carbon fiber-reinforced circular and rectangular concrete column Ongpeng, Jason Maximino C. Lecciones, Isabel Nicole C. Garduque, Jasmine Anne Buera, Daniel Joshua Retrofitting circular and rectangular concrete columns with Carbon Fiber Reinforced Polymer (CFRP) has been proven to be a method of increasing the ultimate confined compressive strength fcc′. The present study uses a hybrid of Analytic Hierarchy Process (AHP) and Backpropagation Artificial Neural Networks (BP) that assesses the strength performance of circular and rectangular columns confined with CFRP, steel ties and a hybrid method using both materials. The data used for the modeling came from available references in journal articles. The process of AHP was first used in determining the best set of independent parameters which are as follows: unconfined concrete strength fco′, ultimate CFRP strength fCFRP, volumetric ratio of CFRP ρCFRP, and steel transversal strength (fsfs ). Additional independent parameters such as the diameter (DD ) and corner radius (rr ) were also included since these were found to have the highest significance on circular columns and rectangular columns, respectively. After utilizing AHP, BP was used as a tool for modeling the fcc′ as an output parameter. From this, two best models were produced for circular and rectangular columns out of twenty BP that were trained, validated and tested. These models were selected based on the Pearson’s correlation coefficient (RR ) which performed better compared to previous existing models from past literature. The BP models attained were C_5_520_5 for circular columns and NC_5_415_6 for rectangular columns. Additionally, a parametric study of the BP models was done to determine the effect of the important input parameter fco′ with the output parameter fcc′. © 2020, Springer Nature Singapore Pte Ltd. 2020-01-01T08:00:00Z text text/html https://animorepository.dlsu.edu.ph/faculty_research/1653 https://animorepository.dlsu.edu.ph/context/faculty_research/article/2652/type/native/viewcontent Faculty Research Work Animo Repository Carbon fiber-reinforced plastics—Compression testing Columns, Concrete—Compression testing Civil Engineering
institution De La Salle University
building De La Salle University Library
continent Asia
country Philippines
Philippines
content_provider De La Salle University Library
collection DLSU Institutional Repository
topic Carbon fiber-reinforced plastics—Compression testing
Columns, Concrete—Compression testing
Civil Engineering
spellingShingle Carbon fiber-reinforced plastics—Compression testing
Columns, Concrete—Compression testing
Civil Engineering
Ongpeng, Jason Maximino C.
Lecciones, Isabel Nicole C.
Garduque, Jasmine Anne
Buera, Daniel Joshua
Ultimate confined compressive strength of carbon fiber-reinforced circular and rectangular concrete column
description Retrofitting circular and rectangular concrete columns with Carbon Fiber Reinforced Polymer (CFRP) has been proven to be a method of increasing the ultimate confined compressive strength fcc′. The present study uses a hybrid of Analytic Hierarchy Process (AHP) and Backpropagation Artificial Neural Networks (BP) that assesses the strength performance of circular and rectangular columns confined with CFRP, steel ties and a hybrid method using both materials. The data used for the modeling came from available references in journal articles. The process of AHP was first used in determining the best set of independent parameters which are as follows: unconfined concrete strength fco′, ultimate CFRP strength fCFRP, volumetric ratio of CFRP ρCFRP, and steel transversal strength (fsfs ). Additional independent parameters such as the diameter (DD ) and corner radius (rr ) were also included since these were found to have the highest significance on circular columns and rectangular columns, respectively. After utilizing AHP, BP was used as a tool for modeling the fcc′ as an output parameter. From this, two best models were produced for circular and rectangular columns out of twenty BP that were trained, validated and tested. These models were selected based on the Pearson’s correlation coefficient (RR ) which performed better compared to previous existing models from past literature. The BP models attained were C_5_520_5 for circular columns and NC_5_415_6 for rectangular columns. Additionally, a parametric study of the BP models was done to determine the effect of the important input parameter fco′ with the output parameter fcc′. © 2020, Springer Nature Singapore Pte Ltd.
format text
author Ongpeng, Jason Maximino C.
Lecciones, Isabel Nicole C.
Garduque, Jasmine Anne
Buera, Daniel Joshua
author_facet Ongpeng, Jason Maximino C.
Lecciones, Isabel Nicole C.
Garduque, Jasmine Anne
Buera, Daniel Joshua
author_sort Ongpeng, Jason Maximino C.
title Ultimate confined compressive strength of carbon fiber-reinforced circular and rectangular concrete column
title_short Ultimate confined compressive strength of carbon fiber-reinforced circular and rectangular concrete column
title_full Ultimate confined compressive strength of carbon fiber-reinforced circular and rectangular concrete column
title_fullStr Ultimate confined compressive strength of carbon fiber-reinforced circular and rectangular concrete column
title_full_unstemmed Ultimate confined compressive strength of carbon fiber-reinforced circular and rectangular concrete column
title_sort ultimate confined compressive strength of carbon fiber-reinforced circular and rectangular concrete column
publisher Animo Repository
publishDate 2020
url https://animorepository.dlsu.edu.ph/faculty_research/1653
https://animorepository.dlsu.edu.ph/context/faculty_research/article/2652/type/native/viewcontent
_version_ 1759860126022369280