Development of an online refractive index monitoring system to detect the end point of transesterification reaction
Refractive index is a physical property which can be used in determining the end point of transesterification in producing biodiesel. The traditional method in acquiring refractive index measurements takes place outside of a transesterification reactor making remote sensing impossible. In this study...
Saved in:
Main Authors: | , , , |
---|---|
Format: | text |
Published: |
Animo Repository
2016
|
Subjects: | |
Online Access: | https://animorepository.dlsu.edu.ph/faculty_research/2064 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | De La Salle University |
id |
oai:animorepository.dlsu.edu.ph:faculty_research-3063 |
---|---|
record_format |
eprints |
spelling |
oai:animorepository.dlsu.edu.ph:faculty_research-30632021-08-13T00:59:13Z Development of an online refractive index monitoring system to detect the end point of transesterification reaction Co, Dana Mae S. Bugtai, Nilo T. Razon, Luis F. Pobre, Romeric F. Refractive index is a physical property which can be used in determining the end point of transesterification in producing biodiesel. The traditional method in acquiring refractive index measurements takes place outside of a transesterification reactor making remote sensing impossible. In this study, a fiber optic cable was used to identify the appropriate wavelength to acquire the refractive index measurement of the mixture as well as fuzzy logic using proportional and derivative errors as its input in determining the end point of transesterification reaction. The different components are used to address real time data acquisition and processing in controlling the continuation or termination of the reaction. It showed that the transesterification reaction of refined, bleached, deodorized coconut oil and methanol using 1-6 molar ratio and 0.003 (by weight of oil) of sodium hydroxide has a mean termination time of 80 minutes with +/- 10 minutes deviation and the percent error compared with measurements from traditional refractometer was less than 0.24%. In doing so, an online system for real time data acquisition and processing was established. The study provides an alternative way to automatically identify the end point of transesterification and successfully presents a method for remote sensing identifying the reaction termination timely to the mixture condition. © 2015 IEEE. 2016-01-25T08:00:00Z text https://animorepository.dlsu.edu.ph/faculty_research/2064 Faculty Research Work Animo Repository Transesterification Biodiesel fuels Refractive index Fiber optic cables Manufacturing |
institution |
De La Salle University |
building |
De La Salle University Library |
continent |
Asia |
country |
Philippines Philippines |
content_provider |
De La Salle University Library |
collection |
DLSU Institutional Repository |
topic |
Transesterification Biodiesel fuels Refractive index Fiber optic cables Manufacturing |
spellingShingle |
Transesterification Biodiesel fuels Refractive index Fiber optic cables Manufacturing Co, Dana Mae S. Bugtai, Nilo T. Razon, Luis F. Pobre, Romeric F. Development of an online refractive index monitoring system to detect the end point of transesterification reaction |
description |
Refractive index is a physical property which can be used in determining the end point of transesterification in producing biodiesel. The traditional method in acquiring refractive index measurements takes place outside of a transesterification reactor making remote sensing impossible. In this study, a fiber optic cable was used to identify the appropriate wavelength to acquire the refractive index measurement of the mixture as well as fuzzy logic using proportional and derivative errors as its input in determining the end point of transesterification reaction. The different components are used to address real time data acquisition and processing in controlling the continuation or termination of the reaction. It showed that the transesterification reaction of refined, bleached, deodorized coconut oil and methanol using 1-6 molar ratio and 0.003 (by weight of oil) of sodium hydroxide has a mean termination time of 80 minutes with +/- 10 minutes deviation and the percent error compared with measurements from traditional refractometer was less than 0.24%. In doing so, an online system for real time data acquisition and processing was established. The study provides an alternative way to automatically identify the end point of transesterification and successfully presents a method for remote sensing identifying the reaction termination timely to the mixture condition. © 2015 IEEE. |
format |
text |
author |
Co, Dana Mae S. Bugtai, Nilo T. Razon, Luis F. Pobre, Romeric F. |
author_facet |
Co, Dana Mae S. Bugtai, Nilo T. Razon, Luis F. Pobre, Romeric F. |
author_sort |
Co, Dana Mae S. |
title |
Development of an online refractive index monitoring system to detect the end point of transesterification reaction |
title_short |
Development of an online refractive index monitoring system to detect the end point of transesterification reaction |
title_full |
Development of an online refractive index monitoring system to detect the end point of transesterification reaction |
title_fullStr |
Development of an online refractive index monitoring system to detect the end point of transesterification reaction |
title_full_unstemmed |
Development of an online refractive index monitoring system to detect the end point of transesterification reaction |
title_sort |
development of an online refractive index monitoring system to detect the end point of transesterification reaction |
publisher |
Animo Repository |
publishDate |
2016 |
url |
https://animorepository.dlsu.edu.ph/faculty_research/2064 |
_version_ |
1709757376454721536 |