Determination of heavy metals in root crops using bismuth nanoparticles modified graphene paste electrode
Electrochemical detection of lead (Pb2+) and cadmium (Cd2+) was accomplished via anodic stripping voltammetry (ASV) using bismuth nanoparticle (BiNP) modified graphene paste electrode (GPE). The electrode was fabricated by mixing bismuth nanoparticles, graphene, and mineral oil and the mixture was p...
Saved in:
Main Authors: | , , , |
---|---|
Format: | text |
Published: |
Animo Repository
2019
|
Subjects: | |
Online Access: | https://animorepository.dlsu.edu.ph/faculty_research/2325 https://animorepository.dlsu.edu.ph/context/faculty_research/article/3324/type/native/viewcontent |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | De La Salle University |
id |
oai:animorepository.dlsu.edu.ph:faculty_research-3324 |
---|---|
record_format |
eprints |
spelling |
oai:animorepository.dlsu.edu.ph:faculty_research-33242022-05-23T01:33:53Z Determination of heavy metals in root crops using bismuth nanoparticles modified graphene paste electrode Palisoc, Shirley Malabuyo, Y. A. Pereja, R. C. Natividad, Michelle T. Electrochemical detection of lead (Pb2+) and cadmium (Cd2+) was accomplished via anodic stripping voltammetry (ASV) using bismuth nanoparticle (BiNP) modified graphene paste electrode (GPE). The electrode was fabricated by mixing bismuth nanoparticles, graphene, and mineral oil and the mixture was packed in a Teflon syringe. The best electrode was determined by varying the amount of BiNP while the amount of graphene and mineral oil were kept constant at 0.21 g and 0.80 μL, respectively. The highest peak currents were obtained using 1.5 mg BiNP modified GPE. The ASV parameters, namely accumulation time, deposition time, and accumulation potential, were optimized. The calibration curve, analytical sensitivity, limit of detection (LOD), and limit of quantitation (LOQ) of the optimized electrode were determined. The correlation values for Pb2+ (R2 = 0.9409) and Cd2+ (R2 = 0.9086) in the calibration curves showed a positive linear relationship between the anodic peak current and heavy metal concentration. The LOD for both Pb2+ and Cd2+ is found to be 100 ppb. The application of the modified electrode on real sample analysis was performed using root crops purchased from local supermarkets. According to ASV and AAS analyses, most of the samples contained Cd2+ while only a few contained Pb2+. Other metals, such as Fe2+ and Cu2+, were also detected via ASV. © 2019, Eesti Pollumajandusulikool. All rights reserved. 2019-01-01T08:00:00Z text text/html https://animorepository.dlsu.edu.ph/faculty_research/2325 https://animorepository.dlsu.edu.ph/context/faculty_research/article/3324/type/native/viewcontent Faculty Research Work Animo Repository Root crops—Heavy metal content Heavy metals Nanoparticles Graphene Voltammetry Physics |
institution |
De La Salle University |
building |
De La Salle University Library |
continent |
Asia |
country |
Philippines Philippines |
content_provider |
De La Salle University Library |
collection |
DLSU Institutional Repository |
topic |
Root crops—Heavy metal content Heavy metals Nanoparticles Graphene Voltammetry Physics |
spellingShingle |
Root crops—Heavy metal content Heavy metals Nanoparticles Graphene Voltammetry Physics Palisoc, Shirley Malabuyo, Y. A. Pereja, R. C. Natividad, Michelle T. Determination of heavy metals in root crops using bismuth nanoparticles modified graphene paste electrode |
description |
Electrochemical detection of lead (Pb2+) and cadmium (Cd2+) was accomplished via anodic stripping voltammetry (ASV) using bismuth nanoparticle (BiNP) modified graphene paste electrode (GPE). The electrode was fabricated by mixing bismuth nanoparticles, graphene, and mineral oil and the mixture was packed in a Teflon syringe. The best electrode was determined by varying the amount of BiNP while the amount of graphene and mineral oil were kept constant at 0.21 g and 0.80 μL, respectively. The highest peak currents were obtained using 1.5 mg BiNP modified GPE. The ASV parameters, namely accumulation time, deposition time, and accumulation potential, were optimized. The calibration curve, analytical sensitivity, limit of detection (LOD), and limit of quantitation (LOQ) of the optimized electrode were determined. The correlation values for Pb2+ (R2 = 0.9409) and Cd2+ (R2 = 0.9086) in the calibration curves showed a positive linear relationship between the anodic peak current and heavy metal concentration. The LOD for both Pb2+ and Cd2+ is found to be 100 ppb. The application of the modified electrode on real sample analysis was performed using root crops purchased from local supermarkets. According to ASV and AAS analyses, most of the samples contained Cd2+ while only a few contained Pb2+. Other metals, such as Fe2+ and Cu2+, were also detected via ASV. © 2019, Eesti Pollumajandusulikool. All rights reserved. |
format |
text |
author |
Palisoc, Shirley Malabuyo, Y. A. Pereja, R. C. Natividad, Michelle T. |
author_facet |
Palisoc, Shirley Malabuyo, Y. A. Pereja, R. C. Natividad, Michelle T. |
author_sort |
Palisoc, Shirley |
title |
Determination of heavy metals in root crops using bismuth nanoparticles modified graphene paste electrode |
title_short |
Determination of heavy metals in root crops using bismuth nanoparticles modified graphene paste electrode |
title_full |
Determination of heavy metals in root crops using bismuth nanoparticles modified graphene paste electrode |
title_fullStr |
Determination of heavy metals in root crops using bismuth nanoparticles modified graphene paste electrode |
title_full_unstemmed |
Determination of heavy metals in root crops using bismuth nanoparticles modified graphene paste electrode |
title_sort |
determination of heavy metals in root crops using bismuth nanoparticles modified graphene paste electrode |
publisher |
Animo Repository |
publishDate |
2019 |
url |
https://animorepository.dlsu.edu.ph/faculty_research/2325 https://animorepository.dlsu.edu.ph/context/faculty_research/article/3324/type/native/viewcontent |
_version_ |
1734392444050472960 |