Microextraction of polychlorinated biphenyls (PCBS) from soil samples

The standard method of polychlorinated biphenyl (PCB) analysis in soil samples requires Soxhlet extraction of gram amount of sample, considerable amounts of hazardous solvents, and a clean-up and extraction time of 3 days per sample. An efficient microextraction procedure has been developed for the...

Full description

Saved in:
Bibliographic Details
Main Authors: Danan, Lieza Marie A., Dimzon, Ian Ken P., Salvan, Christian R., Cayme, Jan-Michael C., Ganancial, Raymond K., Lee, Christine Joy C., Dayrit, Fabian M.
Format: text
Published: Animo Repository 2004
Subjects:
Online Access:https://animorepository.dlsu.edu.ph/faculty_research/5727
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: De La Salle University
id oai:animorepository.dlsu.edu.ph:faculty_research-6440
record_format eprints
spelling oai:animorepository.dlsu.edu.ph:faculty_research-64402022-05-05T00:49:12Z Microextraction of polychlorinated biphenyls (PCBS) from soil samples Danan, Lieza Marie A. Dimzon, Ian Ken P. Salvan, Christian R. Cayme, Jan-Michael C. Ganancial, Raymond K. Lee, Christine Joy C. Dayrit, Fabian M. The standard method of polychlorinated biphenyl (PCB) analysis in soil samples requires Soxhlet extraction of gram amount of sample, considerable amounts of hazardous solvents, and a clean-up and extraction time of 3 days per sample. An efficient microextraction procedure has been developed for the trace quantitative analysis of PCBs in soil samples that will only necessitate a small fraction of the Soxhlet extraction requirements ad still achieve good recoveries for PCB congeners. The microextrcation procedures requires only 0.1g amount of sample and is relatively inexpensive extraction technique, which can be completed within 18 hours. The technique uses standard glassware and only minimal amount of solvent. In this work, parameters such as the type and amount of extracting solvent were evaluated. The congener-specific recoveries of the 20 target PCBs were compared using hexane and heptane as extracting solvents. When compared to the certified concentrations of the 20 congeners in the soil standard reference material (SRM) from the National Institute of Standards and Technology (NIST), the proposed microextraction method using heptane showed excellent recoveries for 10 of the congeners. The other 10 target congeners were found with other PCB congeners or contaminants. Moreover, the recoveries of the 2 surrogate internal standards, PCB #30 and 112, were also within the acceptable limit of ±30% even at 25 ng/g. 2004-02-27T08:00:00Z text https://animorepository.dlsu.edu.ph/faculty_research/5727 Faculty Research Work Animo Repository Polychlorinated biphenyls Soils—Analysis Chemistry
institution De La Salle University
building De La Salle University Library
continent Asia
country Philippines
Philippines
content_provider De La Salle University Library
collection DLSU Institutional Repository
topic Polychlorinated biphenyls
Soils—Analysis
Chemistry
spellingShingle Polychlorinated biphenyls
Soils—Analysis
Chemistry
Danan, Lieza Marie A.
Dimzon, Ian Ken P.
Salvan, Christian R.
Cayme, Jan-Michael C.
Ganancial, Raymond K.
Lee, Christine Joy C.
Dayrit, Fabian M.
Microextraction of polychlorinated biphenyls (PCBS) from soil samples
description The standard method of polychlorinated biphenyl (PCB) analysis in soil samples requires Soxhlet extraction of gram amount of sample, considerable amounts of hazardous solvents, and a clean-up and extraction time of 3 days per sample. An efficient microextraction procedure has been developed for the trace quantitative analysis of PCBs in soil samples that will only necessitate a small fraction of the Soxhlet extraction requirements ad still achieve good recoveries for PCB congeners. The microextrcation procedures requires only 0.1g amount of sample and is relatively inexpensive extraction technique, which can be completed within 18 hours. The technique uses standard glassware and only minimal amount of solvent. In this work, parameters such as the type and amount of extracting solvent were evaluated. The congener-specific recoveries of the 20 target PCBs were compared using hexane and heptane as extracting solvents. When compared to the certified concentrations of the 20 congeners in the soil standard reference material (SRM) from the National Institute of Standards and Technology (NIST), the proposed microextraction method using heptane showed excellent recoveries for 10 of the congeners. The other 10 target congeners were found with other PCB congeners or contaminants. Moreover, the recoveries of the 2 surrogate internal standards, PCB #30 and 112, were also within the acceptable limit of ±30% even at 25 ng/g.
format text
author Danan, Lieza Marie A.
Dimzon, Ian Ken P.
Salvan, Christian R.
Cayme, Jan-Michael C.
Ganancial, Raymond K.
Lee, Christine Joy C.
Dayrit, Fabian M.
author_facet Danan, Lieza Marie A.
Dimzon, Ian Ken P.
Salvan, Christian R.
Cayme, Jan-Michael C.
Ganancial, Raymond K.
Lee, Christine Joy C.
Dayrit, Fabian M.
author_sort Danan, Lieza Marie A.
title Microextraction of polychlorinated biphenyls (PCBS) from soil samples
title_short Microextraction of polychlorinated biphenyls (PCBS) from soil samples
title_full Microextraction of polychlorinated biphenyls (PCBS) from soil samples
title_fullStr Microextraction of polychlorinated biphenyls (PCBS) from soil samples
title_full_unstemmed Microextraction of polychlorinated biphenyls (PCBS) from soil samples
title_sort microextraction of polychlorinated biphenyls (pcbs) from soil samples
publisher Animo Repository
publishDate 2004
url https://animorepository.dlsu.edu.ph/faculty_research/5727
_version_ 1767196355284959232