Spectrogram analysis of electrocardiogram with normal sinus rhythm, arrhythmia and atrial fibrillation

This paper intends to identify a method to distinguish between ECG signals from the Normal Sinus Rhythm (NSR) database and those from the Arrhythmia database. It also attempts to distinguish between NSR and Atrial Fibrillation (Afib). The ECG samples were taken from the database of MIT-BIH. For the...

Full description

Saved in:
Bibliographic Details
Main Authors: Segismundo, M. J., Villanueva, M. M. F., Ramos, Catherine Manuela L.
Format: text
Published: Animo Repository 2012
Subjects:
Online Access:https://animorepository.dlsu.edu.ph/faculty_research/5752
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: De La Salle University
id oai:animorepository.dlsu.edu.ph:faculty_research-6752
record_format eprints
spelling oai:animorepository.dlsu.edu.ph:faculty_research-67522022-05-20T06:56:19Z Spectrogram analysis of electrocardiogram with normal sinus rhythm, arrhythmia and atrial fibrillation Segismundo, M. J. Villanueva, M. M. F. Ramos, Catherine Manuela L. This paper intends to identify a method to distinguish between ECG signals from the Normal Sinus Rhythm (NSR) database and those from the Arrhythmia database. It also attempts to distinguish between NSR and Atrial Fibrillation (Afib). The ECG samples were taken from the database of MIT-BIH. For the first experiment, three-second segments of the entire ECG signals of NSR and that of the P wave alone were analyzed using their power spectral density (PSD). These were then compared to the ECG and P wave of those with Arrhythmia. Spectrum of the P wave clearly differentiates NSR and Arrhythmia. NSR signals exhibit a band within the 10 Hz region while ECG with arrhythmia has a frequency band less than 10 Hz. Furthermore, the dominant frequencies of the NSR extend up to 10 Hz while that of an arrhythmic ECG has very low dominant frequencies. For the second experiment, NSR and Afib signals were cut into 10-second segments. The Afib signals contain annotation marking episodes of normal rhythm and atrial fibrillation. NSR signals show significant frequency content up to more than 30 Hz while majority of the normal rhythm episodes from Afib had significant spectral content concentrated around 4 Hz with lower spectral density than that of NSR. 2012-01-01T08:00:00Z text https://animorepository.dlsu.edu.ph/faculty_research/5752 Faculty Research Work Animo Repository Electrocardiography Power spectra Sinoatrial node Biomedical Electrical and Computer Engineering
institution De La Salle University
building De La Salle University Library
continent Asia
country Philippines
Philippines
content_provider De La Salle University Library
collection DLSU Institutional Repository
topic Electrocardiography
Power spectra
Sinoatrial node
Biomedical
Electrical and Computer Engineering
spellingShingle Electrocardiography
Power spectra
Sinoatrial node
Biomedical
Electrical and Computer Engineering
Segismundo, M. J.
Villanueva, M. M. F.
Ramos, Catherine Manuela L.
Spectrogram analysis of electrocardiogram with normal sinus rhythm, arrhythmia and atrial fibrillation
description This paper intends to identify a method to distinguish between ECG signals from the Normal Sinus Rhythm (NSR) database and those from the Arrhythmia database. It also attempts to distinguish between NSR and Atrial Fibrillation (Afib). The ECG samples were taken from the database of MIT-BIH. For the first experiment, three-second segments of the entire ECG signals of NSR and that of the P wave alone were analyzed using their power spectral density (PSD). These were then compared to the ECG and P wave of those with Arrhythmia. Spectrum of the P wave clearly differentiates NSR and Arrhythmia. NSR signals exhibit a band within the 10 Hz region while ECG with arrhythmia has a frequency band less than 10 Hz. Furthermore, the dominant frequencies of the NSR extend up to 10 Hz while that of an arrhythmic ECG has very low dominant frequencies. For the second experiment, NSR and Afib signals were cut into 10-second segments. The Afib signals contain annotation marking episodes of normal rhythm and atrial fibrillation. NSR signals show significant frequency content up to more than 30 Hz while majority of the normal rhythm episodes from Afib had significant spectral content concentrated around 4 Hz with lower spectral density than that of NSR.
format text
author Segismundo, M. J.
Villanueva, M. M. F.
Ramos, Catherine Manuela L.
author_facet Segismundo, M. J.
Villanueva, M. M. F.
Ramos, Catherine Manuela L.
author_sort Segismundo, M. J.
title Spectrogram analysis of electrocardiogram with normal sinus rhythm, arrhythmia and atrial fibrillation
title_short Spectrogram analysis of electrocardiogram with normal sinus rhythm, arrhythmia and atrial fibrillation
title_full Spectrogram analysis of electrocardiogram with normal sinus rhythm, arrhythmia and atrial fibrillation
title_fullStr Spectrogram analysis of electrocardiogram with normal sinus rhythm, arrhythmia and atrial fibrillation
title_full_unstemmed Spectrogram analysis of electrocardiogram with normal sinus rhythm, arrhythmia and atrial fibrillation
title_sort spectrogram analysis of electrocardiogram with normal sinus rhythm, arrhythmia and atrial fibrillation
publisher Animo Repository
publishDate 2012
url https://animorepository.dlsu.edu.ph/faculty_research/5752
_version_ 1767196417941569536