Measurement of scattered dose through thermoluminescent dosimeters (TLD) in the contralateral breast for tangential beam breast irradiation for patients in Metro Manila
Tangential beam breast irradiation treats target tissues while avoiding the lungs and the contralatcral breast. Scatter radiation to the contralateral breast can cause secondary malignancy if the glandular tissue absorbs more than the dose limit for breast. This study is the first in the Philippine...
Saved in:
Main Authors: | , , |
---|---|
Format: | text |
Published: |
Animo Repository
2005
|
Subjects: | |
Online Access: | https://animorepository.dlsu.edu.ph/faculty_research/8152 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | De La Salle University |
id |
oai:animorepository.dlsu.edu.ph:faculty_research-8853 |
---|---|
record_format |
eprints |
spelling |
oai:animorepository.dlsu.edu.ph:faculty_research-88532023-01-20T05:51:29Z Measurement of scattered dose through thermoluminescent dosimeters (TLD) in the contralateral breast for tangential beam breast irradiation for patients in Metro Manila Moreno, Dickerson C. Lopez, F. A. Santacera, Raquel Irene Tangential beam breast irradiation treats target tissues while avoiding the lungs and the contralatcral breast. Scatter radiation to the contralateral breast can cause secondary malignancy if the glandular tissue absorbs more than the dose limit for breast. This study is the first in the Philippines to measure the scatter dose received by an intact, contralateral breast during tangential beam radiotherapy for breast cancer. Seven patients with intact breasts undergoing tangential beam radiotherapy were asked to participate. Four thermoluminescent dosimeters (TLDs), placed under 1.5 cm bolus, were used for each patient. TLDs were read at the National Cancer Center in South Korea. The effective dose on each patient was compared to the breast dose limit. The results show that there is no reason to believe that the scatter dose received by the patients is enough to start a secondary malignancy. 2005-01-01T08:00:00Z text https://animorepository.dlsu.edu.ph/faculty_research/8152 Faculty Research Work Animo Repository Breast—Cancer—Radiotherapy Radiation dosimetry Medicine and Health Sciences |
institution |
De La Salle University |
building |
De La Salle University Library |
continent |
Asia |
country |
Philippines Philippines |
content_provider |
De La Salle University Library |
collection |
DLSU Institutional Repository |
topic |
Breast—Cancer—Radiotherapy Radiation dosimetry Medicine and Health Sciences |
spellingShingle |
Breast—Cancer—Radiotherapy Radiation dosimetry Medicine and Health Sciences Moreno, Dickerson C. Lopez, F. A. Santacera, Raquel Irene Measurement of scattered dose through thermoluminescent dosimeters (TLD) in the contralateral breast for tangential beam breast irradiation for patients in Metro Manila |
description |
Tangential beam breast irradiation treats target tissues while avoiding the lungs and the contralatcral breast. Scatter radiation to the contralateral breast can cause secondary malignancy if the glandular tissue absorbs more than the dose limit for breast. This study is the first in the Philippines to measure the scatter dose received by an intact, contralateral breast during tangential beam radiotherapy for breast cancer. Seven patients with intact breasts undergoing tangential beam radiotherapy were asked to participate. Four thermoluminescent dosimeters (TLDs), placed under 1.5 cm bolus, were used for each patient. TLDs were read at the National Cancer Center in South Korea. The effective dose on each patient was compared to the breast dose limit. The results show that there is no reason to believe that the scatter dose received by the patients is enough to start a secondary malignancy. |
format |
text |
author |
Moreno, Dickerson C. Lopez, F. A. Santacera, Raquel Irene |
author_facet |
Moreno, Dickerson C. Lopez, F. A. Santacera, Raquel Irene |
author_sort |
Moreno, Dickerson C. |
title |
Measurement of scattered dose through thermoluminescent dosimeters (TLD) in the contralateral breast for tangential beam breast irradiation for patients in Metro Manila |
title_short |
Measurement of scattered dose through thermoluminescent dosimeters (TLD) in the contralateral breast for tangential beam breast irradiation for patients in Metro Manila |
title_full |
Measurement of scattered dose through thermoluminescent dosimeters (TLD) in the contralateral breast for tangential beam breast irradiation for patients in Metro Manila |
title_fullStr |
Measurement of scattered dose through thermoluminescent dosimeters (TLD) in the contralateral breast for tangential beam breast irradiation for patients in Metro Manila |
title_full_unstemmed |
Measurement of scattered dose through thermoluminescent dosimeters (TLD) in the contralateral breast for tangential beam breast irradiation for patients in Metro Manila |
title_sort |
measurement of scattered dose through thermoluminescent dosimeters (tld) in the contralateral breast for tangential beam breast irradiation for patients in metro manila |
publisher |
Animo Repository |
publishDate |
2005 |
url |
https://animorepository.dlsu.edu.ph/faculty_research/8152 |
_version_ |
1767196841551593472 |