Fire behaviour of waterborne intumescent coatings on timber substrate for bushfire exposure

The fire behaviour of radiata pine timber, treated with intumescent coatings and exposed to heat flux conditions equivalent to a high-risk bushfire attack level (BAL) is investigated. The experiment is designed for coated timber exposed to bushfire attack levels greater than 19 kW/m2 and up to 29 kW...

Full description

Saved in:
Bibliographic Details
Main Authors: Baena, J.C., Wang, C., Kabir, I.I., Khalid, A., Nazir, M.T., Yuen, A.C.Y., Ahmad, F., Yeoh, G.H.
Format: Article
Published: Elsevier Ltd 2023
Online Access:http://scholars.utp.edu.my/id/eprint/37340/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85163725638&doi=10.1016%2fj.firesaf.2023.103836&partnerID=40&md5=4999428d203aa700e020ca6b9271b7ba
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Petronas
id oai:scholars.utp.edu.my:37340
record_format eprints
spelling oai:scholars.utp.edu.my:373402023-10-04T08:42:02Z http://scholars.utp.edu.my/id/eprint/37340/ Fire behaviour of waterborne intumescent coatings on timber substrate for bushfire exposure Baena, J.C. Wang, C. Kabir, I.I. Khalid, A. Nazir, M.T. Yuen, A.C.Y. Ahmad, F. Yeoh, G.H. The fire behaviour of radiata pine timber, treated with intumescent coatings and exposed to heat flux conditions equivalent to a high-risk bushfire attack level (BAL) is investigated. The experiment is designed for coated timber exposed to bushfire attack levels greater than 19 kW/m2 and up to 29 kW/m2 (BAL-29) in accordance with AS 3959. The timber was coated with a DFT of 400 μm of the developed intumescent formulations based on expandable graphite (EG), ammonium polyphosphate (APP) and a waterborne acrylic resin with high adhesion strength. The coated timbers were tested according to AS3959, for a BAL-29 rating, using a cone calorimeter at 25 kW/m2 for 10 min. Most of the coated samples reported a substantial reduction in the peak heat release rate (p-HRR) and average HRR with values not greater than 100 kW/m2 and 60 kW/m2, respectively. These results satisfy the requirements for bushfire-resistant timber at BAL-29 rating. Formulation 4 (F4), with EG:APP ratio of 3:1 and resin content of 45 wt was identified as the most cost-effective formulation. Coatings with high loading of EG and APP provided the best fire protection to the timber substrate, however, a larger char with a less compact structure is formed. © 2023 Elsevier Ltd Elsevier Ltd 2023 Article NonPeerReviewed Baena, J.C. and Wang, C. and Kabir, I.I. and Khalid, A. and Nazir, M.T. and Yuen, A.C.Y. and Ahmad, F. and Yeoh, G.H. (2023) Fire behaviour of waterborne intumescent coatings on timber substrate for bushfire exposure. Fire Safety Journal, 140. ISSN 03797112 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85163725638&doi=10.1016%2fj.firesaf.2023.103836&partnerID=40&md5=4999428d203aa700e020ca6b9271b7ba 10.1016/j.firesaf.2023.103836 10.1016/j.firesaf.2023.103836 10.1016/j.firesaf.2023.103836
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description The fire behaviour of radiata pine timber, treated with intumescent coatings and exposed to heat flux conditions equivalent to a high-risk bushfire attack level (BAL) is investigated. The experiment is designed for coated timber exposed to bushfire attack levels greater than 19 kW/m2 and up to 29 kW/m2 (BAL-29) in accordance with AS 3959. The timber was coated with a DFT of 400 μm of the developed intumescent formulations based on expandable graphite (EG), ammonium polyphosphate (APP) and a waterborne acrylic resin with high adhesion strength. The coated timbers were tested according to AS3959, for a BAL-29 rating, using a cone calorimeter at 25 kW/m2 for 10 min. Most of the coated samples reported a substantial reduction in the peak heat release rate (p-HRR) and average HRR with values not greater than 100 kW/m2 and 60 kW/m2, respectively. These results satisfy the requirements for bushfire-resistant timber at BAL-29 rating. Formulation 4 (F4), with EG:APP ratio of 3:1 and resin content of 45 wt was identified as the most cost-effective formulation. Coatings with high loading of EG and APP provided the best fire protection to the timber substrate, however, a larger char with a less compact structure is formed. © 2023 Elsevier Ltd
format Article
author Baena, J.C.
Wang, C.
Kabir, I.I.
Khalid, A.
Nazir, M.T.
Yuen, A.C.Y.
Ahmad, F.
Yeoh, G.H.
spellingShingle Baena, J.C.
Wang, C.
Kabir, I.I.
Khalid, A.
Nazir, M.T.
Yuen, A.C.Y.
Ahmad, F.
Yeoh, G.H.
Fire behaviour of waterborne intumescent coatings on timber substrate for bushfire exposure
author_facet Baena, J.C.
Wang, C.
Kabir, I.I.
Khalid, A.
Nazir, M.T.
Yuen, A.C.Y.
Ahmad, F.
Yeoh, G.H.
author_sort Baena, J.C.
title Fire behaviour of waterborne intumescent coatings on timber substrate for bushfire exposure
title_short Fire behaviour of waterborne intumescent coatings on timber substrate for bushfire exposure
title_full Fire behaviour of waterborne intumescent coatings on timber substrate for bushfire exposure
title_fullStr Fire behaviour of waterborne intumescent coatings on timber substrate for bushfire exposure
title_full_unstemmed Fire behaviour of waterborne intumescent coatings on timber substrate for bushfire exposure
title_sort fire behaviour of waterborne intumescent coatings on timber substrate for bushfire exposure
publisher Elsevier Ltd
publishDate 2023
url http://scholars.utp.edu.my/id/eprint/37340/
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85163725638&doi=10.1016%2fj.firesaf.2023.103836&partnerID=40&md5=4999428d203aa700e020ca6b9271b7ba
_version_ 1779441368032083968