Remote and Real-time Sensor System for Groundwater Level and Quality
The increasing demand for freshwater supply in the Philippines forces unsustainable extraction and unintentional contamination of the groundwater reservoirs. It is thus imperative that the groundwater sources be monitored for water level and quality. The Philippines has groundwater monitoring wells...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | text |
Published: |
Archīum Ateneo
2020
|
Subjects: | |
Online Access: | https://archium.ateneo.edu/ecce-faculty-pubs/82 https://ieeexplore.ieee.org/document/9301948 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Ateneo De Manila University |
id |
ph-ateneo-arc.ecce-faculty-pubs-1081 |
---|---|
record_format |
eprints |
spelling |
ph-ateneo-arc.ecce-faculty-pubs-10812022-02-24T16:21:27Z Remote and Real-time Sensor System for Groundwater Level and Quality Oppus, Carlos M Guico, Maria Leonora Monje, Jose Claro N Guzman, Ma. Aileen Leah G Ngo, Genevieve C Retirado, Mark Glenn F Kwong, John Chris T The increasing demand for freshwater supply in the Philippines forces unsustainable extraction and unintentional contamination of the groundwater reservoirs. It is thus imperative that the groundwater sources be monitored for water level and quality. The Philippines has groundwater monitoring wells strategically installed in locations identified as critical areas. Accessibility of location and high cost of provisions and logistics prevent proper maintenance and continuous monitoring of these groundwater wells. This project addresses these by deploying a remote real-time groundwater level and quality sensor system. The groundwater wells initially monitored are located over three sites in Metro Manila, namely, Malabon, Marikina, and Alabang. Each site has a sensor system that collects and transmits seven parameters related to static water level and water quality and the deployed module's power status. With a solar charging component, the deployed module can power itself for at least 6 months with minimal maintenance. The system delivers the maximum transmission reliability of 92% in the field with hourly sending rates and more than satisfies the required one data set per day minimum by the funding agency. 2020-01-01T08:00:00Z text https://archium.ateneo.edu/ecce-faculty-pubs/82 https://ieeexplore.ieee.org/document/9301948 Electronics, Computer, and Communications Engineering Faculty Publications Archīum Ateneo Groundwater Quality Monitoring Water Level Monitoring System Deployment Real-time Remote Monitoring Computer Engineering Electrical and Computer Engineering |
institution |
Ateneo De Manila University |
building |
Ateneo De Manila University Library |
continent |
Asia |
country |
Philippines Philippines |
content_provider |
Ateneo De Manila University Library |
collection |
archium.Ateneo Institutional Repository |
topic |
Groundwater Quality Monitoring Water Level Monitoring System Deployment Real-time Remote Monitoring Computer Engineering Electrical and Computer Engineering |
spellingShingle |
Groundwater Quality Monitoring Water Level Monitoring System Deployment Real-time Remote Monitoring Computer Engineering Electrical and Computer Engineering Oppus, Carlos M Guico, Maria Leonora Monje, Jose Claro N Guzman, Ma. Aileen Leah G Ngo, Genevieve C Retirado, Mark Glenn F Kwong, John Chris T Remote and Real-time Sensor System for Groundwater Level and Quality |
description |
The increasing demand for freshwater supply in the Philippines forces unsustainable extraction and unintentional contamination of the groundwater reservoirs. It is thus imperative that the groundwater sources be monitored for water level and quality. The Philippines has groundwater monitoring wells strategically installed in locations identified as critical areas. Accessibility of location and high cost of provisions and logistics prevent proper maintenance and continuous monitoring of these groundwater wells. This project addresses these by deploying a remote real-time groundwater level and quality sensor system. The groundwater wells initially monitored are located over three sites in Metro Manila, namely, Malabon, Marikina, and Alabang. Each site has a sensor system that collects and transmits seven parameters related to static water level and water quality and the deployed module's power status. With a solar charging component, the deployed module can power itself for at least 6 months with minimal maintenance. The system delivers the maximum transmission reliability of 92% in the field with hourly sending rates and more than satisfies the required one data set per day minimum by the funding agency. |
format |
text |
author |
Oppus, Carlos M Guico, Maria Leonora Monje, Jose Claro N Guzman, Ma. Aileen Leah G Ngo, Genevieve C Retirado, Mark Glenn F Kwong, John Chris T |
author_facet |
Oppus, Carlos M Guico, Maria Leonora Monje, Jose Claro N Guzman, Ma. Aileen Leah G Ngo, Genevieve C Retirado, Mark Glenn F Kwong, John Chris T |
author_sort |
Oppus, Carlos M |
title |
Remote and Real-time Sensor System for Groundwater Level and Quality |
title_short |
Remote and Real-time Sensor System for Groundwater Level and Quality |
title_full |
Remote and Real-time Sensor System for Groundwater Level and Quality |
title_fullStr |
Remote and Real-time Sensor System for Groundwater Level and Quality |
title_full_unstemmed |
Remote and Real-time Sensor System for Groundwater Level and Quality |
title_sort |
remote and real-time sensor system for groundwater level and quality |
publisher |
Archīum Ateneo |
publishDate |
2020 |
url |
https://archium.ateneo.edu/ecce-faculty-pubs/82 https://ieeexplore.ieee.org/document/9301948 |
_version_ |
1726158626714812416 |