Fluidic actuation of an elastomeric grating

A fluidic chamber with an elastomeric grating membrane is fabricated. Grating groove spacing is modified through membrane deformation via fluid injection. Tunable diffraction output is demonstrated. At normal incidence, the diffraction angle changes by 14.2° and 9.8° for incident wavelengths 632.8 a...

全面介紹

Saved in:
書目詳細資料
Main Authors: Guerrero, Raphael A, Oliva, Sarah Jaye C, Indias, Johanna Mae M
格式: text
出版: Archīum Ateneo 2012
主題:
在線閱讀:https://archium.ateneo.edu/physics-faculty-pubs/10
https://www.osapublishing.org/ao/abstract.cfm?uri=ao-51-24-5812
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
機構: Ateneo De Manila University
id ph-ateneo-arc.physics-faculty-pubs-1009
record_format eprints
spelling ph-ateneo-arc.physics-faculty-pubs-10092020-03-11T08:58:03Z Fluidic actuation of an elastomeric grating Guerrero, Raphael A Oliva, Sarah Jaye C Indias, Johanna Mae M A fluidic chamber with an elastomeric grating membrane is fabricated. Grating groove spacing is modified through membrane deformation via fluid injection. Tunable diffraction output is demonstrated. At normal incidence, the diffraction angle changes by 14.2° and 9.8° for incident wavelengths 632.8 and 488 nm, respectively, with an injected fluid volume of 1 ml. 2012-08-13T07:00:00Z text application/pdf https://archium.ateneo.edu/physics-faculty-pubs/10 https://www.osapublishing.org/ao/abstract.cfm?uri=ao-51-24-5812 Physics Faculty Publications Archīum Ateneo Optics Physics
institution Ateneo De Manila University
building Ateneo De Manila University Library
country Philippines
collection archium.Ateneo Institutional Repository
topic Optics
Physics
spellingShingle Optics
Physics
Guerrero, Raphael A
Oliva, Sarah Jaye C
Indias, Johanna Mae M
Fluidic actuation of an elastomeric grating
description A fluidic chamber with an elastomeric grating membrane is fabricated. Grating groove spacing is modified through membrane deformation via fluid injection. Tunable diffraction output is demonstrated. At normal incidence, the diffraction angle changes by 14.2° and 9.8° for incident wavelengths 632.8 and 488 nm, respectively, with an injected fluid volume of 1 ml.
format text
author Guerrero, Raphael A
Oliva, Sarah Jaye C
Indias, Johanna Mae M
author_facet Guerrero, Raphael A
Oliva, Sarah Jaye C
Indias, Johanna Mae M
author_sort Guerrero, Raphael A
title Fluidic actuation of an elastomeric grating
title_short Fluidic actuation of an elastomeric grating
title_full Fluidic actuation of an elastomeric grating
title_fullStr Fluidic actuation of an elastomeric grating
title_full_unstemmed Fluidic actuation of an elastomeric grating
title_sort fluidic actuation of an elastomeric grating
publisher Archīum Ateneo
publishDate 2012
url https://archium.ateneo.edu/physics-faculty-pubs/10
https://www.osapublishing.org/ao/abstract.cfm?uri=ao-51-24-5812
_version_ 1681506547606224896