Novel biosensor for interleukin-6 detection
Interleukin-6 (IL-6) is a pleiotropic cytokine with an important role in both immune regulation and exercise metabolism. During exercise, IL-6 is predominantly produced within, and released from, the working skeletal muscle, with the magnitude of IL-6 release related to the duration and intensity of...
Saved in:
Main Authors: | , , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2013
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/100892 http://hdl.handle.net/10220/18196 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-100892 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1008922023-07-14T15:55:05Z Novel biosensor for interleukin-6 detection Nimmo, Myra A. Huang, Jingfeng Harvey, James Fam, Derrick Wen Hui Tok, Alfred Iing Yoong School of Materials Science & Engineering Institute for Sports Research DRNTU::Engineering::Materials Interleukin-6 (IL-6) is a pleiotropic cytokine with an important role in both immune regulation and exercise metabolism. During exercise, IL-6 is predominantly produced within, and released from, the working skeletal muscle, with the magnitude of IL-6 release related to the duration and intensity of the exercise bout. IL-6 (a) is the first cytokine to appear in circulation following initiation of exercise and (b) undergoes the most pronounced increase as compared to any cytokine in response to exercise. In the last decade, studies have suggested a role for IL-6 as a muscle energy sensor, pointing to its potential role as a biomarker of overtraining. Currently, ELISA and western blot is the staple detection technique for IL-6. However, they require substantial time, cost, machinery and specialist training. On the other hand, a Graphene Oxide-based amperometric sensor can provide real-time, low-cost yet sensitive protein detection. But, the coverage of mono-layered Graphene Oxide (GO) flake on SiO2 substrate is limited due to rinsing and unwanted crosslinking of the 3-AminoPropylTriEthoxy Silane (APTES) adhesion layer, thus leading to low available GO surface area, high variability of electrical conductivity between chips and low sheet transconductance that limits sensitivity of the sensor. This work had overcome this limitation by depositing carbon on the edges of GO flakes using an ethanol chemical vapor deposition (CVD). Then, the post-treated GO is fabricated into a liquid-gated biosensor and the detection window for IL-6 is presented. Our work yielded a highly conductive and electrically homogeneous carbon-based transducer to enable low-cost, facile, real-time yet sensitive amperometric sensors for IL-6. EDB (Economic Devt. Board, S’pore) Published version 2013-12-10T02:39:04Z 2019-12-06T20:29:50Z 2013-12-10T02:39:04Z 2019-12-06T20:29:50Z 2013 2013 Journal Article Huang, J., Harvey, J., Fam, D. W. H., Nimmo, M. A., & Tok, I. A. (2013). Novel biosensor for interleukin-6 detection. Procedia engineering, 60, 195-200. 1877-7058 https://hdl.handle.net/10356/100892 http://hdl.handle.net/10220/18196 10.1016/j.proeng.2013.07.042 en Procedia engineering © 2013 The Authors. Published by Elsevier Ltd. This paper was published in Procedia Engineering and is made available as an electronic reprint (preprint) with permission of The Authors. Published by Elsevier Ltd.. The paper can be found at the following official DOI: http://dx.doi.org/10.1016/j.proeng.2013.07.042. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Engineering::Materials |
spellingShingle |
DRNTU::Engineering::Materials Nimmo, Myra A. Huang, Jingfeng Harvey, James Fam, Derrick Wen Hui Tok, Alfred Iing Yoong Novel biosensor for interleukin-6 detection |
description |
Interleukin-6 (IL-6) is a pleiotropic cytokine with an important role in both immune regulation and exercise metabolism. During exercise, IL-6 is predominantly produced within, and released from, the working skeletal muscle, with the magnitude of IL-6 release related to the duration and intensity of the exercise bout. IL-6 (a) is the first cytokine to appear in circulation following initiation of exercise and (b) undergoes the most pronounced increase as compared to any cytokine in response to exercise. In the last decade, studies have suggested a role for IL-6 as a muscle energy sensor, pointing to its potential role as a biomarker of overtraining. Currently, ELISA and western blot is the staple detection technique for IL-6. However, they require substantial time, cost, machinery and specialist training. On the other hand, a Graphene Oxide-based amperometric sensor can provide real-time, low-cost yet sensitive protein detection. But, the coverage of mono-layered Graphene Oxide (GO) flake on SiO2 substrate is limited due to rinsing and unwanted crosslinking of the 3-AminoPropylTriEthoxy Silane (APTES) adhesion layer, thus leading to low available GO surface area, high variability of electrical conductivity between chips and low sheet transconductance that limits sensitivity of the sensor. This work had overcome this limitation by depositing carbon on the edges of GO flakes using an ethanol chemical vapor deposition (CVD). Then, the post-treated GO is fabricated into a liquid-gated biosensor and the detection window for IL-6 is presented. Our work yielded a highly conductive and electrically homogeneous carbon-based transducer to enable low-cost, facile, real-time yet sensitive amperometric sensors for IL-6. |
author2 |
School of Materials Science & Engineering |
author_facet |
School of Materials Science & Engineering Nimmo, Myra A. Huang, Jingfeng Harvey, James Fam, Derrick Wen Hui Tok, Alfred Iing Yoong |
format |
Article |
author |
Nimmo, Myra A. Huang, Jingfeng Harvey, James Fam, Derrick Wen Hui Tok, Alfred Iing Yoong |
author_sort |
Nimmo, Myra A. |
title |
Novel biosensor for interleukin-6 detection |
title_short |
Novel biosensor for interleukin-6 detection |
title_full |
Novel biosensor for interleukin-6 detection |
title_fullStr |
Novel biosensor for interleukin-6 detection |
title_full_unstemmed |
Novel biosensor for interleukin-6 detection |
title_sort |
novel biosensor for interleukin-6 detection |
publishDate |
2013 |
url |
https://hdl.handle.net/10356/100892 http://hdl.handle.net/10220/18196 |
_version_ |
1772827803778023424 |