Determination of short-term power dispatch schedule for a wind farm incorporated with dual-battery energy storage scheme

A battery energy storage scheme to enable short-term dispatch commitment from a grid-connected wind-turbine generating power station is considered. Among the various types of energy storage medium, technical factors leading to the selection of battery are explained. The scheme utilizes two battery e...

全面介紹

Saved in:
書目詳細資料
Main Authors: Yao, D. L., Lie, T. T., Choi, San Shing, Tseng, King Jet
其他作者: School of Electrical and Electronic Engineering
格式: Article
語言:English
出版: 2013
主題:
在線閱讀:https://hdl.handle.net/10356/102003
http://hdl.handle.net/10220/16500
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
機構: Nanyang Technological University
語言: English
id sg-ntu-dr.10356-102003
record_format dspace
spelling sg-ntu-dr.10356-1020032020-03-07T14:00:35Z Determination of short-term power dispatch schedule for a wind farm incorporated with dual-battery energy storage scheme Yao, D. L. Lie, T. T. Choi, San Shing Tseng, King Jet School of Electrical and Electronic Engineering Centre for Smart Energy Systems DRNTU::Engineering::Computer science and engineering::Information systems::Information storage and retrieval A battery energy storage scheme to enable short-term dispatch commitment from a grid-connected wind-turbine generating power station is considered. Among the various types of energy storage medium, technical factors leading to the selection of battery are explained. The scheme utilizes two battery energy storage systems (BESS) in which the generated wind power charges one BESS while concurrently, the second BESS is to discharge power into the grid. The role of the two BESS interchanges when the BESS reaches specified state of charge/discharge. Furthermore, based on forecasted charging wind power and the monitored states of charge of the two BESS, the discharge power level from the generating station is determined and scheduled a few hours ahead. The dispatch scheme maximizes wind energy harnessed, achieved with the minimum number of the BESS switch-overs. The design thus prolongs the service life of the BESS. Numerical examples to demonstrate the performance of the scheme are also included. 2013-10-16T01:52:45Z 2019-12-06T20:48:14Z 2013-10-16T01:52:45Z 2019-12-06T20:48:14Z 2012 2012 Journal Article Yao, D. L., Choi, S. S., Tseng, K. J., & Lie, J. J. (2012). Determination of short-term power dispatch schedule for a wind farm incorporated with dual-battery energy storage scheme. IEEE transactions on sustainable energy, 3(1), 74-84. https://hdl.handle.net/10356/102003 http://hdl.handle.net/10220/16500 10.1109/TSTE.2011.2163092 en IEEE transactions on sustainable energy
institution Nanyang Technological University
building NTU Library
country Singapore
collection DR-NTU
language English
topic DRNTU::Engineering::Computer science and engineering::Information systems::Information storage and retrieval
spellingShingle DRNTU::Engineering::Computer science and engineering::Information systems::Information storage and retrieval
Yao, D. L.
Lie, T. T.
Choi, San Shing
Tseng, King Jet
Determination of short-term power dispatch schedule for a wind farm incorporated with dual-battery energy storage scheme
description A battery energy storage scheme to enable short-term dispatch commitment from a grid-connected wind-turbine generating power station is considered. Among the various types of energy storage medium, technical factors leading to the selection of battery are explained. The scheme utilizes two battery energy storage systems (BESS) in which the generated wind power charges one BESS while concurrently, the second BESS is to discharge power into the grid. The role of the two BESS interchanges when the BESS reaches specified state of charge/discharge. Furthermore, based on forecasted charging wind power and the monitored states of charge of the two BESS, the discharge power level from the generating station is determined and scheduled a few hours ahead. The dispatch scheme maximizes wind energy harnessed, achieved with the minimum number of the BESS switch-overs. The design thus prolongs the service life of the BESS. Numerical examples to demonstrate the performance of the scheme are also included.
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Yao, D. L.
Lie, T. T.
Choi, San Shing
Tseng, King Jet
format Article
author Yao, D. L.
Lie, T. T.
Choi, San Shing
Tseng, King Jet
author_sort Yao, D. L.
title Determination of short-term power dispatch schedule for a wind farm incorporated with dual-battery energy storage scheme
title_short Determination of short-term power dispatch schedule for a wind farm incorporated with dual-battery energy storage scheme
title_full Determination of short-term power dispatch schedule for a wind farm incorporated with dual-battery energy storage scheme
title_fullStr Determination of short-term power dispatch schedule for a wind farm incorporated with dual-battery energy storage scheme
title_full_unstemmed Determination of short-term power dispatch schedule for a wind farm incorporated with dual-battery energy storage scheme
title_sort determination of short-term power dispatch schedule for a wind farm incorporated with dual-battery energy storage scheme
publishDate 2013
url https://hdl.handle.net/10356/102003
http://hdl.handle.net/10220/16500
_version_ 1681036722584944640