Comparing the magnetic resonant coupling radiofrequency stimulation to the traditional approaches: Ex-vivo tissue voltage measurement and electromagnetic simulation analysis

Recently, the design concept of magnetic resonant coupling has been adapted to electromagnetic therapy applications such as non-invasive radiofrequency (RF) stimulation. This technique can significantly increase the electric field radiated from the magnetic coil at the stimulation target, and hence...

Full description

Saved in:
Bibliographic Details
Main Authors: Yeung, Sai Ho, Pradhan, Raunaq, Feng, Xiaohua, Zheng, Yuanjin
Other Authors: School of Electrical and Electronic Engineering
Format: Article
Language:English
Published: 2015
Online Access:https://hdl.handle.net/10356/103530
http://hdl.handle.net/10220/38752
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-103530
record_format dspace
spelling sg-ntu-dr.10356-1035302020-03-07T14:00:37Z Comparing the magnetic resonant coupling radiofrequency stimulation to the traditional approaches: Ex-vivo tissue voltage measurement and electromagnetic simulation analysis Yeung, Sai Ho Pradhan, Raunaq Feng, Xiaohua Zheng, Yuanjin School of Electrical and Electronic Engineering Recently, the design concept of magnetic resonant coupling has been adapted to electromagnetic therapy applications such as non-invasive radiofrequency (RF) stimulation. This technique can significantly increase the electric field radiated from the magnetic coil at the stimulation target, and hence enhancing the current flowing through the nerve, thus enabling stimulation. In this paper, the developed magnetic resonant coupling (MRC) stimulation, magnetic stimulation (MS) and transcutaneous electrical nerve stimulation (TENS) are compared. The differences between the MRC RF stimulation and other techniques are presented in terms of the operating mechanism, ex-vivo tissue voltage measurement and electromagnetic simulation analysis. The ev-vivo tissue voltage measurement experiment is performed on the compared devices based on measuring the voltage induced by electromagnetic induction at the tissue. The focusing effect, E field and voltage induced across the tissue, and the attenuation due to the increase of separation between the coil and the target are analyzed. The electromagnetic stimulation will also be performed to obtain the electric field and magnetic field distribution around the biological medium. The electric field intensity is proportional to the induced current and the magnetic field is corresponding to the electromagnetic induction across the biological medium. The comparison between the MRC RF stimulator and the MS and TENS devices revealed that the MRC RF stimulator has several advantages over the others for the applications of inducing current in the biological medium for stimulation purposes. Published version 2015-09-25T07:05:56Z 2019-12-06T21:14:41Z 2015-09-25T07:05:56Z 2019-12-06T21:14:41Z 2015 2015 Journal Article Yeung, S. H., Pradhan, R., Feng, X., & Zheng, Y. (2015). Comparing the magnetic resonant coupling radiofrequency stimulation to the traditional approaches: Ex-vivo tissue voltage measurement and electromagnetic simulation analysis. AIP Advances, 5(9), 097110-. 2158-3226 https://hdl.handle.net/10356/103530 http://hdl.handle.net/10220/38752 10.1063/1.4930533 en AIP Advances © 2015 The Author(s) (published by American Institute of Physics). This paper was published in AIP Advances and is made available as an electronic reprint (preprint) with permission of The Author(s) (published by American Institute of Physics). The published version is available at: [http://dx.doi.org/10.1063/1.4930533]. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law. application/pdf
institution Nanyang Technological University
building NTU Library
country Singapore
collection DR-NTU
language English
description Recently, the design concept of magnetic resonant coupling has been adapted to electromagnetic therapy applications such as non-invasive radiofrequency (RF) stimulation. This technique can significantly increase the electric field radiated from the magnetic coil at the stimulation target, and hence enhancing the current flowing through the nerve, thus enabling stimulation. In this paper, the developed magnetic resonant coupling (MRC) stimulation, magnetic stimulation (MS) and transcutaneous electrical nerve stimulation (TENS) are compared. The differences between the MRC RF stimulation and other techniques are presented in terms of the operating mechanism, ex-vivo tissue voltage measurement and electromagnetic simulation analysis. The ev-vivo tissue voltage measurement experiment is performed on the compared devices based on measuring the voltage induced by electromagnetic induction at the tissue. The focusing effect, E field and voltage induced across the tissue, and the attenuation due to the increase of separation between the coil and the target are analyzed. The electromagnetic stimulation will also be performed to obtain the electric field and magnetic field distribution around the biological medium. The electric field intensity is proportional to the induced current and the magnetic field is corresponding to the electromagnetic induction across the biological medium. The comparison between the MRC RF stimulator and the MS and TENS devices revealed that the MRC RF stimulator has several advantages over the others for the applications of inducing current in the biological medium for stimulation purposes.
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Yeung, Sai Ho
Pradhan, Raunaq
Feng, Xiaohua
Zheng, Yuanjin
format Article
author Yeung, Sai Ho
Pradhan, Raunaq
Feng, Xiaohua
Zheng, Yuanjin
spellingShingle Yeung, Sai Ho
Pradhan, Raunaq
Feng, Xiaohua
Zheng, Yuanjin
Comparing the magnetic resonant coupling radiofrequency stimulation to the traditional approaches: Ex-vivo tissue voltage measurement and electromagnetic simulation analysis
author_sort Yeung, Sai Ho
title Comparing the magnetic resonant coupling radiofrequency stimulation to the traditional approaches: Ex-vivo tissue voltage measurement and electromagnetic simulation analysis
title_short Comparing the magnetic resonant coupling radiofrequency stimulation to the traditional approaches: Ex-vivo tissue voltage measurement and electromagnetic simulation analysis
title_full Comparing the magnetic resonant coupling radiofrequency stimulation to the traditional approaches: Ex-vivo tissue voltage measurement and electromagnetic simulation analysis
title_fullStr Comparing the magnetic resonant coupling radiofrequency stimulation to the traditional approaches: Ex-vivo tissue voltage measurement and electromagnetic simulation analysis
title_full_unstemmed Comparing the magnetic resonant coupling radiofrequency stimulation to the traditional approaches: Ex-vivo tissue voltage measurement and electromagnetic simulation analysis
title_sort comparing the magnetic resonant coupling radiofrequency stimulation to the traditional approaches: ex-vivo tissue voltage measurement and electromagnetic simulation analysis
publishDate 2015
url https://hdl.handle.net/10356/103530
http://hdl.handle.net/10220/38752
_version_ 1681037259326881792