Two new parameters to assess anterior chamber angle for SS-OCT images

In this paper, we propose an automatic quantitative assessment method of the anterior chamber angle of the eye using swept source optical coherence tomography (SS-OCT) images. The angle structure was assessed by two new parameters: 1) mean of continuous measurement of angle opening distance (mAOD) c...

Full description

Saved in:
Bibliographic Details
Main Authors: Ni, Soe Ni, Tian, Jing, Marziliano, Pina, Wong, Hon Tym
Other Authors: School of Electrical and Electronic Engineering
Format: Conference or Workshop Item
Language:English
Published: 2013
Subjects:
Online Access:https://hdl.handle.net/10356/106072
http://hdl.handle.net/10220/17955
http://dx.doi.org/10.1109/ISBI.2013.6556776
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-106072
record_format dspace
spelling sg-ntu-dr.10356-1060722019-12-06T22:04:06Z Two new parameters to assess anterior chamber angle for SS-OCT images Ni, Soe Ni Tian, Jing Marziliano, Pina Wong, Hon Tym School of Electrical and Electronic Engineering IEEE International Symposium on Biomedical Imaging (10th : 2013 : San Francisco, California, US) DRNTU::Engineering::Electrical and electronic engineering In this paper, we propose an automatic quantitative assessment method of the anterior chamber angle of the eye using swept source optical coherence tomography (SS-OCT) images. The angle structure was assessed by two new parameters: 1) mean of continuous measurement of angle opening distance (mAOD) centered on Schwalbe's line; and 2) area of the anterior chamber (AAC). In this research, two hundred and fifty-two SS-OCT images were analyzed. The measurements of open and closed angle in SS-OCT images were compared with that of Schwalbe's line based single angle assessment (AOD_sl, ARA_sl). Our continuous based AOD measurement shows over 93% correlation with the single based AOD angle assessment but provides a more reliable and accurate measurement for open and closed angle SS-OCT images. These newly proposed parameters give a better representation of the angle width for capturing the nature of the angle dynamics involved in different forms of angle closure or open angle glaucoma. 2013-11-29T07:27:51Z 2019-12-06T22:04:06Z 2013-11-29T07:27:51Z 2019-12-06T22:04:06Z 2013 2013 Conference Paper Ni, S. N., Tian, J., Marziliano, P., & Wong, H. T. (2013). Two new parameters to assess anterior chamber angle for SS-OCT images. In Proceedings of 10th IEEE International Symposium on Biomedical Imaging 2013, 1324-1327. https://hdl.handle.net/10356/106072 http://hdl.handle.net/10220/17955 http://dx.doi.org/10.1109/ISBI.2013.6556776 en
institution Nanyang Technological University
building NTU Library
country Singapore
collection DR-NTU
language English
topic DRNTU::Engineering::Electrical and electronic engineering
spellingShingle DRNTU::Engineering::Electrical and electronic engineering
Ni, Soe Ni
Tian, Jing
Marziliano, Pina
Wong, Hon Tym
Two new parameters to assess anterior chamber angle for SS-OCT images
description In this paper, we propose an automatic quantitative assessment method of the anterior chamber angle of the eye using swept source optical coherence tomography (SS-OCT) images. The angle structure was assessed by two new parameters: 1) mean of continuous measurement of angle opening distance (mAOD) centered on Schwalbe's line; and 2) area of the anterior chamber (AAC). In this research, two hundred and fifty-two SS-OCT images were analyzed. The measurements of open and closed angle in SS-OCT images were compared with that of Schwalbe's line based single angle assessment (AOD_sl, ARA_sl). Our continuous based AOD measurement shows over 93% correlation with the single based AOD angle assessment but provides a more reliable and accurate measurement for open and closed angle SS-OCT images. These newly proposed parameters give a better representation of the angle width for capturing the nature of the angle dynamics involved in different forms of angle closure or open angle glaucoma.
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Ni, Soe Ni
Tian, Jing
Marziliano, Pina
Wong, Hon Tym
format Conference or Workshop Item
author Ni, Soe Ni
Tian, Jing
Marziliano, Pina
Wong, Hon Tym
author_sort Ni, Soe Ni
title Two new parameters to assess anterior chamber angle for SS-OCT images
title_short Two new parameters to assess anterior chamber angle for SS-OCT images
title_full Two new parameters to assess anterior chamber angle for SS-OCT images
title_fullStr Two new parameters to assess anterior chamber angle for SS-OCT images
title_full_unstemmed Two new parameters to assess anterior chamber angle for SS-OCT images
title_sort two new parameters to assess anterior chamber angle for ss-oct images
publishDate 2013
url https://hdl.handle.net/10356/106072
http://hdl.handle.net/10220/17955
http://dx.doi.org/10.1109/ISBI.2013.6556776
_version_ 1681042233789251584