Continuous blood oxygen saturation detection with single-wavelength photoacoustics
Blood oxygen saturation (SO2) reflects the oxygenation level in blood transport and tissue. Previous studies have shown the capability of non-invasive quantitative measurements of SO2 by multi-wavelength photoacoustic (PA) spectroscopy for diagnosis of brain, tumor hemodynamics and other pathophysio...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2015
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/107386 http://hdl.handle.net/10220/25549 http://dx.doi.org/10.1117/12.2077105 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-107386 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1073862019-12-06T22:29:48Z Continuous blood oxygen saturation detection with single-wavelength photoacoustics Peng, Qiwen Gao, Fei Feng, Xiaohua Zheng, Yuanjin Oraevsky, Alexander A. Wang, Lihong V. School of Electrical and Electronic Engineering Progress in Biomedical Optics and Imaging - Proceedings of SPIE DRNTU::Science::Medicine::Biomedical engineering Blood oxygen saturation (SO2) reflects the oxygenation level in blood transport and tissue. Previous studies have shown the capability of non-invasive quantitative measurements of SO2 by multi-wavelength photoacoustic (PA) spectroscopy for diagnosis of brain, tumor hemodynamics and other pathophysiological phenomena. However, those multi-wavelength methods require a tunable laser or multiple lasers which are relatively expensive and bulky for filed measurement environment and applications. Besides, the operation of multiple wavelengths, calibration procedures and data processing gets system complicated, which reduces the feasibility and flexibility for continuous real-time monitoring. Here we report a newly proposed method by combining PA and scattered light signals wherein imposing a hypothesis that scattering intensity is linear to the concentrations of oxygenated hemoglobin and deoxygenated hemoglobin weighed by blood scattering coefficients. A rigorous theoretical relationship between PA and scattering signals is thus established, making it possible that SO2 can be measured with only one excitation wavelength. To verify the theory basis, both dual-ink phantoms and fresh porcine blood sample have been employed in the experiments. The phantom experiment is able to quantify the concentration of mixed red-green ink that is in precise agreement with pre-set values. The ex vivo experiment with fresh porcine blood was conducted and the results of the proposed single-wavelength method achieved high accuracy of 1% - 4% errors. These demonstrated that the proposed single-wavelength SO2 detection is able to provide non-invasive, accurate measurement of blood oxygenation, and herein create potential for applying it to real clinical applications with low cost and high flexibility. Published version 2015-05-14T07:52:31Z 2019-12-06T22:29:48Z 2015-05-14T07:52:31Z 2019-12-06T22:29:48Z 2015 2015 Conference Paper Peng, Q., Gao, F., Feng, X., & Zheng, Y. (2015). Continuous blood oxygen saturation detection with single-wavelength photoacoustics. Progress in biomedical optics and imaging - Proceedings of SPIE. https://hdl.handle.net/10356/107386 http://hdl.handle.net/10220/25549 http://dx.doi.org/10.1117/12.2077105 en © 2015 SPIE. This paper was published in Progress in Biomedical Optics and Imaging - Proceedings of SPIE and is made available as an electronic reprint (preprint) with permission of SPIE. The paper can be found at the following official DOI: [http://dx.doi.org/10.1117/12.2077105]. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law. 7 p. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
country |
Singapore |
collection |
DR-NTU |
language |
English |
topic |
DRNTU::Science::Medicine::Biomedical engineering |
spellingShingle |
DRNTU::Science::Medicine::Biomedical engineering Peng, Qiwen Gao, Fei Feng, Xiaohua Zheng, Yuanjin Continuous blood oxygen saturation detection with single-wavelength photoacoustics |
description |
Blood oxygen saturation (SO2) reflects the oxygenation level in blood transport and tissue. Previous studies have shown the capability of non-invasive quantitative measurements of SO2 by multi-wavelength photoacoustic (PA) spectroscopy for diagnosis of brain, tumor hemodynamics and other pathophysiological phenomena. However, those multi-wavelength methods require a tunable laser or multiple lasers which are relatively expensive and bulky for filed measurement environment and applications. Besides, the operation of multiple wavelengths, calibration procedures and data processing gets system complicated, which reduces the feasibility and flexibility for continuous real-time monitoring. Here we report a newly proposed method by combining PA and scattered light signals wherein imposing a hypothesis that scattering intensity is linear to the concentrations of oxygenated hemoglobin and deoxygenated hemoglobin weighed by blood scattering coefficients. A rigorous theoretical relationship between PA and scattering signals is thus established, making it possible that SO2 can be measured with only one excitation wavelength. To verify the theory basis, both dual-ink phantoms and fresh porcine blood sample have been employed in the experiments. The phantom experiment is able to quantify the concentration of mixed red-green ink that is in precise agreement with pre-set values. The ex vivo experiment with fresh porcine blood was conducted and the results of the proposed single-wavelength method achieved high accuracy of 1% - 4% errors. These demonstrated that the proposed single-wavelength SO2 detection is able to provide non-invasive, accurate measurement of blood oxygenation, and herein create potential for applying it to real clinical applications with low cost and high flexibility. |
author2 |
Oraevsky, Alexander A. |
author_facet |
Oraevsky, Alexander A. Peng, Qiwen Gao, Fei Feng, Xiaohua Zheng, Yuanjin |
format |
Conference or Workshop Item |
author |
Peng, Qiwen Gao, Fei Feng, Xiaohua Zheng, Yuanjin |
author_sort |
Peng, Qiwen |
title |
Continuous blood oxygen saturation detection with single-wavelength photoacoustics |
title_short |
Continuous blood oxygen saturation detection with single-wavelength photoacoustics |
title_full |
Continuous blood oxygen saturation detection with single-wavelength photoacoustics |
title_fullStr |
Continuous blood oxygen saturation detection with single-wavelength photoacoustics |
title_full_unstemmed |
Continuous blood oxygen saturation detection with single-wavelength photoacoustics |
title_sort |
continuous blood oxygen saturation detection with single-wavelength photoacoustics |
publishDate |
2015 |
url |
https://hdl.handle.net/10356/107386 http://hdl.handle.net/10220/25549 http://dx.doi.org/10.1117/12.2077105 |
_version_ |
1681044245050294272 |