Fire resistance of steel and composite columns
A programme of experimental testing has been conducted to investigate the behaviour of steel columns and concrete-encased steel section composite columns at elevated temperature. Heating is attained in an electric furnace. Measurements of internal forces, lateral deflections, axial displacements and...
Saved in:
Main Author: | Phng, Eugene Guan Hwee |
---|---|
Other Authors: | Tan Kang Hai |
Format: | Theses and Dissertations |
Language: | English |
Published: |
2008
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/11980 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
Similar Items
-
Fire resistance of reinforced concrete columns
by: Yao, Yao.
Published: (2008) -
Interactive formula for fire resistance of columns
by: Tang, Chuyang.
Published: (2008) -
Fire resistance analysis of steel structures
by: Cheong, Hee Kiat.
Published: (2008) -
Fire resistance of RC columns using finite element method
by: Guo, Gillian Yihui.
Published: (2009) -
Assessment of reinforcement concrete and composite steel-concrete columns to resist the effects of suitcase bombs
by: Wu, Ke-Chiang.
Published: (2011)