Engineering compliant, small diameter vascular prosthesis for bypass grafting

Mechanical mismatch between vascular grafts and blood vessels is a major cause of smaller diameter graft (< 6 mm) failure. The fabrication of a compliant small diameter prosthesis remains elusive, due to the idiosyncratic elastic properties of arterial wall tissue. Native blood vessels exhibit a...

Full description

Saved in:
Bibliographic Details
Main Author: Behr, Jean-Marc Benedikt
Other Authors: Subbu S. Venkatraman
Format: Thesis-Doctor of Philosophy
Language:English
Published: Nanyang Technological University 2019
Subjects:
Online Access:https://hdl.handle.net/10356/136554
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-136554
record_format dspace
spelling sg-ntu-dr.10356-1365542023-03-04T16:44:52Z Engineering compliant, small diameter vascular prosthesis for bypass grafting Behr, Jean-Marc Benedikt Subbu S. Venkatraman School of Materials Science & Engineering ASSubbu@ntu.edu.sg Engineering::Materials Mechanical mismatch between vascular grafts and blood vessels is a major cause of smaller diameter graft (< 6 mm) failure. The fabrication of a compliant small diameter prosthesis remains elusive, due to the idiosyncratic elastic properties of arterial wall tissue. Native blood vessels exhibit a pressure-dependent compliance (non-linear elasticity), which is a principal reason behind the decade-long search for a clinical solution for small diameter vessel replacement. Mimicking the non-linear elastic properties of arterial tissue is the major goal in this thesis and has been achieved over multiple steps. Initial research involved the evaluation of several poly-L-lactide-co-ε-caprolactone (PLC) copolymers as candidate materials for the fabrication of small diameter grafts. Using these materials, tubular prostheses of 4 mm inner diameter were produced by dip-coating. In vitro static and dynamic compliance tests were conducted, using a custom-built apparatus. Mechanical testing revealed a compliance-dependence on the monomer composition and the wall-thickness (WT) of the PLC tubes. PLC 70:30 tubes of 150 μm WT were similarly compliant as the porcine arteries. These tubes were assessed in a three hours in vivo experiment in a lupine model as an aortic bypass on their implantation and function. The recorded angiogram showed continuous blood flow, no aneurysmal dilatation, leaks or acute thrombosis, indicating the potential for clinical applications. In order to achieve non-linear elasticity, different approaches were pursued, such as adding a soft inner lining to a PLC tube or outer melt-drawn fibers. However, none of these methods produced satisfying results. Hence, a third strategy was followed up, by combining a soft dip-coated tube with a 3D-printed outer pliable mesh. In an initial test, single spring-like fibers were assessed on their tensile properties. All fibers showed clear signs of non-linear elasticity, displaying an increasing elastic modulus upon unfolding in the stress-strain diagrams (J-Curve). Among the all tested spring geometries, the semi-hexagonal (HEX) were the most satisfying. Based on the results from the tensile experiments, meshes of different designs were printed and wrapped around a soft dip-coated PLC 70:30 tube to form a mesh-tube composite (JM-Tube). Initially, the dip-coated tube was not elastic enough to sufficiently unfold the mesh and moreover expanded between the mesh struts. Fiber unfolding was facilitated when using HEX-meshes with two spring sections that were separated by a middle glue strip. This configuration allowed a better stress transfer from the tube to the fiber to enable easier unfolding. A reduction of the WT of the PLC 70:30 tube from ~100 μm to ~55 μm made the tube sufficiently elastic so that it could expand easily to force the mesh fibers to unfold. The use of meshes with high fiber coverage minimized tubular inter-strut expansion. By combining these three advances, the JM-Tubes then displayed the desired non-linear elastic properties. This work demonstrates arterial-like compliance properties can be achieved by combining a soft dip-coated tube with a pliable stiffer outer mesh. Further optimizations in the design are required, to improve the compliance matching to native arteries. Doctor of Philosophy 2019-12-27T08:27:33Z 2019-12-27T08:27:33Z 2018 Thesis-Doctor of Philosophy Behr, J.-M. B. (2018). Engineering compliant, small diameter vascular prosthesis for bypass grafting. Doctoral thesis, Nanyang Technological University, Singapore. https://hdl.handle.net/10356/136554 10.32657/10356/136554 en This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0). application/pdf Nanyang Technological University
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Materials
spellingShingle Engineering::Materials
Behr, Jean-Marc Benedikt
Engineering compliant, small diameter vascular prosthesis for bypass grafting
description Mechanical mismatch between vascular grafts and blood vessels is a major cause of smaller diameter graft (< 6 mm) failure. The fabrication of a compliant small diameter prosthesis remains elusive, due to the idiosyncratic elastic properties of arterial wall tissue. Native blood vessels exhibit a pressure-dependent compliance (non-linear elasticity), which is a principal reason behind the decade-long search for a clinical solution for small diameter vessel replacement. Mimicking the non-linear elastic properties of arterial tissue is the major goal in this thesis and has been achieved over multiple steps. Initial research involved the evaluation of several poly-L-lactide-co-ε-caprolactone (PLC) copolymers as candidate materials for the fabrication of small diameter grafts. Using these materials, tubular prostheses of 4 mm inner diameter were produced by dip-coating. In vitro static and dynamic compliance tests were conducted, using a custom-built apparatus. Mechanical testing revealed a compliance-dependence on the monomer composition and the wall-thickness (WT) of the PLC tubes. PLC 70:30 tubes of 150 μm WT were similarly compliant as the porcine arteries. These tubes were assessed in a three hours in vivo experiment in a lupine model as an aortic bypass on their implantation and function. The recorded angiogram showed continuous blood flow, no aneurysmal dilatation, leaks or acute thrombosis, indicating the potential for clinical applications. In order to achieve non-linear elasticity, different approaches were pursued, such as adding a soft inner lining to a PLC tube or outer melt-drawn fibers. However, none of these methods produced satisfying results. Hence, a third strategy was followed up, by combining a soft dip-coated tube with a 3D-printed outer pliable mesh. In an initial test, single spring-like fibers were assessed on their tensile properties. All fibers showed clear signs of non-linear elasticity, displaying an increasing elastic modulus upon unfolding in the stress-strain diagrams (J-Curve). Among the all tested spring geometries, the semi-hexagonal (HEX) were the most satisfying. Based on the results from the tensile experiments, meshes of different designs were printed and wrapped around a soft dip-coated PLC 70:30 tube to form a mesh-tube composite (JM-Tube). Initially, the dip-coated tube was not elastic enough to sufficiently unfold the mesh and moreover expanded between the mesh struts. Fiber unfolding was facilitated when using HEX-meshes with two spring sections that were separated by a middle glue strip. This configuration allowed a better stress transfer from the tube to the fiber to enable easier unfolding. A reduction of the WT of the PLC 70:30 tube from ~100 μm to ~55 μm made the tube sufficiently elastic so that it could expand easily to force the mesh fibers to unfold. The use of meshes with high fiber coverage minimized tubular inter-strut expansion. By combining these three advances, the JM-Tubes then displayed the desired non-linear elastic properties. This work demonstrates arterial-like compliance properties can be achieved by combining a soft dip-coated tube with a pliable stiffer outer mesh. Further optimizations in the design are required, to improve the compliance matching to native arteries.
author2 Subbu S. Venkatraman
author_facet Subbu S. Venkatraman
Behr, Jean-Marc Benedikt
format Thesis-Doctor of Philosophy
author Behr, Jean-Marc Benedikt
author_sort Behr, Jean-Marc Benedikt
title Engineering compliant, small diameter vascular prosthesis for bypass grafting
title_short Engineering compliant, small diameter vascular prosthesis for bypass grafting
title_full Engineering compliant, small diameter vascular prosthesis for bypass grafting
title_fullStr Engineering compliant, small diameter vascular prosthesis for bypass grafting
title_full_unstemmed Engineering compliant, small diameter vascular prosthesis for bypass grafting
title_sort engineering compliant, small diameter vascular prosthesis for bypass grafting
publisher Nanyang Technological University
publishDate 2019
url https://hdl.handle.net/10356/136554
_version_ 1759853169771282432