Develop the controller for dual-mode thermosiphon beam

Air-conditioning is one of the greatest inventions in history. It brings comfort to the occupants by reducing the room temperature and relative humidity. In commercial buildings, offices and civil-service buildings, HVAC system increases the occupants’ working efficiency and public efficiency as occ...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Chew, Kok Joon
مؤلفون آخرون: Cai Wenjian
التنسيق: Final Year Project
اللغة:English
منشور في: Nanyang Technological University 2020
الموضوعات:
الوصول للمادة أونلاين:https://hdl.handle.net/10356/138888
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
المؤسسة: Nanyang Technological University
اللغة: English
id sg-ntu-dr.10356-138888
record_format dspace
spelling sg-ntu-dr.10356-1388882023-07-07T18:35:19Z Develop the controller for dual-mode thermosiphon beam Chew, Kok Joon Cai Wenjian School of Electrical and Electronic Engineering Energy Research Institute @NTU ewjcai@ntu.edu.sg Engineering::Electrical and electronic engineering Air-conditioning is one of the greatest inventions in history. It brings comfort to the occupants by reducing the room temperature and relative humidity. In commercial buildings, offices and civil-service buildings, HVAC system increases the occupants’ working efficiency and public efficiency as occupants are more able to focus in their comfort zone. There are mainly 4 types of HVAC systems such as single-split system, multi-split system, VAV system and VRF system. The most common system is single-split system which mostly used in small offices, shops and houses while VAV system is used for a bigger cooling foot print such as healthcare centre, commercial malls and hotel. These HVAC systems require high power and energy supplies to provide an ideal indoor environment to the occupants. Not only that, VAV system requires long air ducting, chilled water pipes and air handling unit to deliver cool air to the occupied spaces. As the society started to take note of the sustainability issues and promote environmentally friendly systems, thermosiphon beam system has become new trend of HVAC. Besides that, thermosiphon beam system required low energy consumption and installation costs. Thermosiphon beam systems can be operated in 2 modes which are passive and active modes. However, an efficient controlling system is needed to control the operation of thermosiphon beams in both modes and provide a good indoor environmental quality to the occupants. The testing and development of the thermosiphon beam controller will be conducted in Energy Research Institute Lab in Nanyang Technological University. Bachelor of Engineering (Electrical and Electronic Engineering) 2020-05-13T08:56:45Z 2020-05-13T08:56:45Z 2020 Final Year Project (FYP) https://hdl.handle.net/10356/138888 en A1024-191 application/pdf Nanyang Technological University
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Electrical and electronic engineering
spellingShingle Engineering::Electrical and electronic engineering
Chew, Kok Joon
Develop the controller for dual-mode thermosiphon beam
description Air-conditioning is one of the greatest inventions in history. It brings comfort to the occupants by reducing the room temperature and relative humidity. In commercial buildings, offices and civil-service buildings, HVAC system increases the occupants’ working efficiency and public efficiency as occupants are more able to focus in their comfort zone. There are mainly 4 types of HVAC systems such as single-split system, multi-split system, VAV system and VRF system. The most common system is single-split system which mostly used in small offices, shops and houses while VAV system is used for a bigger cooling foot print such as healthcare centre, commercial malls and hotel. These HVAC systems require high power and energy supplies to provide an ideal indoor environment to the occupants. Not only that, VAV system requires long air ducting, chilled water pipes and air handling unit to deliver cool air to the occupied spaces. As the society started to take note of the sustainability issues and promote environmentally friendly systems, thermosiphon beam system has become new trend of HVAC. Besides that, thermosiphon beam system required low energy consumption and installation costs. Thermosiphon beam systems can be operated in 2 modes which are passive and active modes. However, an efficient controlling system is needed to control the operation of thermosiphon beams in both modes and provide a good indoor environmental quality to the occupants. The testing and development of the thermosiphon beam controller will be conducted in Energy Research Institute Lab in Nanyang Technological University.
author2 Cai Wenjian
author_facet Cai Wenjian
Chew, Kok Joon
format Final Year Project
author Chew, Kok Joon
author_sort Chew, Kok Joon
title Develop the controller for dual-mode thermosiphon beam
title_short Develop the controller for dual-mode thermosiphon beam
title_full Develop the controller for dual-mode thermosiphon beam
title_fullStr Develop the controller for dual-mode thermosiphon beam
title_full_unstemmed Develop the controller for dual-mode thermosiphon beam
title_sort develop the controller for dual-mode thermosiphon beam
publisher Nanyang Technological University
publishDate 2020
url https://hdl.handle.net/10356/138888
_version_ 1772827670650814464