Portable photoacoustic system for noninvasive blood temperature measurement
A miniaturized sensing system for noninvasive measurement of blood temperature with relatively deeper penetration has being long pursued with limited success. Here, we develop a novel photoacoustics based portable sensor for noninvasive monitoring of blood temperature with high accuracy, deep penetr...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2020
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/140396 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-140396 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1403962020-05-28T09:01:29Z Portable photoacoustic system for noninvasive blood temperature measurement Liu, Siyu Feng, Xiaohua Zhang, Ruochong Zheng, Yuanjin School of Electrical and Electronic Engineering 2018 IEEE International Symposium on Circuits and Systems (ISCAS) Engineering::Electrical and electronic engineering Photoacoustic Portable Device A miniaturized sensing system for noninvasive measurement of blood temperature with relatively deeper penetration has being long pursued with limited success. Here, we develop a novel photoacoustics based portable sensor for noninvasive monitoring of blood temperature with high accuracy, deep penetration depth and real time capability. Optical module (laser diode with collimation lens) and acoustic module (ring ultrasound transducer with an optical/acoustic transparent Polydimethylsiloxane coupling layer) of the system is integrated to a compact sensor head with a size similar to a human thumb. Main body is battery-powered to provide the laser driver, data acquisition and also signal processing. The overall system size is around 14 cm×8 cm×3 cm. Temperature calibration and measurement is demonstrated both on phantom and animal to achieve a high accuracy of 0.2 and 0.5 degree respectively, with a fast refreshing speed of 80 Hz. In the future, such developed photoacoustic temperature sensing device can potentially become a wearable patch sensor with further miniaturization of laser diode and use of MEMS-based piezoelectric micro-machined ultrasonic transducers (PMUT). 2020-05-28T09:01:29Z 2020-05-28T09:01:29Z 2018 Conference Paper Liu, S., Feng, X., Zhang, R., & Zheng, Y. (2018). Portable photoacoustic system for noninvasive blood temperature measurement. Proceedings of the 2018 IEEE International Symposium on Circuits and Systems (ISCAS). doi:10.1109/ISCAS.2018.8351607 978-1-5386-4881-0 2379-447X https://hdl.handle.net/10356/140396 10.1109/ISCAS.2018.8351607 en © 2018 IEEE. All rights reserved. |
institution |
Nanyang Technological University |
building |
NTU Library |
country |
Singapore |
collection |
DR-NTU |
language |
English |
topic |
Engineering::Electrical and electronic engineering Photoacoustic Portable Device |
spellingShingle |
Engineering::Electrical and electronic engineering Photoacoustic Portable Device Liu, Siyu Feng, Xiaohua Zhang, Ruochong Zheng, Yuanjin Portable photoacoustic system for noninvasive blood temperature measurement |
description |
A miniaturized sensing system for noninvasive measurement of blood temperature with relatively deeper penetration has being long pursued with limited success. Here, we develop a novel photoacoustics based portable sensor for noninvasive monitoring of blood temperature with high accuracy, deep penetration depth and real time capability. Optical module (laser diode with collimation lens) and acoustic module (ring ultrasound transducer with an optical/acoustic transparent Polydimethylsiloxane coupling layer) of the system is integrated to a compact sensor head with a size similar to a human thumb. Main body is battery-powered to provide the laser driver, data acquisition and also signal processing. The overall system size is around 14 cm×8 cm×3 cm. Temperature calibration and measurement is demonstrated both on phantom and animal to achieve a high accuracy of 0.2 and 0.5 degree respectively, with a fast refreshing speed of 80 Hz. In the future, such developed photoacoustic temperature sensing device can potentially become a wearable patch sensor with further miniaturization of laser diode and use of MEMS-based piezoelectric micro-machined ultrasonic transducers (PMUT). |
author2 |
School of Electrical and Electronic Engineering |
author_facet |
School of Electrical and Electronic Engineering Liu, Siyu Feng, Xiaohua Zhang, Ruochong Zheng, Yuanjin |
format |
Conference or Workshop Item |
author |
Liu, Siyu Feng, Xiaohua Zhang, Ruochong Zheng, Yuanjin |
author_sort |
Liu, Siyu |
title |
Portable photoacoustic system for noninvasive blood temperature measurement |
title_short |
Portable photoacoustic system for noninvasive blood temperature measurement |
title_full |
Portable photoacoustic system for noninvasive blood temperature measurement |
title_fullStr |
Portable photoacoustic system for noninvasive blood temperature measurement |
title_full_unstemmed |
Portable photoacoustic system for noninvasive blood temperature measurement |
title_sort |
portable photoacoustic system for noninvasive blood temperature measurement |
publishDate |
2020 |
url |
https://hdl.handle.net/10356/140396 |
_version_ |
1681058616348508160 |