Stability analysis of PV generators with consideration of P&O-based power control
Photovoltaic (PV) generators have continuously increased in recent years, whose power is usually controlled through the perturbation and observation (P&O) method. In essence, the P&O method is nonlinear and discontinuous. Hence, the conventional small-signal stability analysis is not suitabl...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2020
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/140499 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-140499 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1404992020-05-29T08:56:50Z Stability analysis of PV generators with consideration of P&O-based power control Xia, Yanghong Wei, Wei Yu, Miao Wang, Peng School of Electrical and Electronic Engineering Engineering::Electrical and electronic engineering Describing Function (DF) Perturbation And Observation (P&O) Method Photovoltaic (PV) generators have continuously increased in recent years, whose power is usually controlled through the perturbation and observation (P&O) method. In essence, the P&O method is nonlinear and discontinuous. Hence, the conventional small-signal stability analysis is not suitable anymore when the influence of the P&O-based power control is considered. Focusing on this problem, this paper adopts the nonlinear describing function (DF) method to conduct the accurate stability analysis of PV generators with consideration of P&O-based power control. The detailed procedures about the DF method are introduced, and then the related influence factors like perturbation size, filters, and so on are analyzed quantitatively. Furthermore, the comparison with the conventional stability analysis methods is made, which suggests that the DF method can effectively enhance the accuracy of the stability analysis. All the conclusions are verified by the real-time hardware-in-loop tests. 2020-05-29T08:56:49Z 2020-05-29T08:56:49Z 2018 Journal Article Xia, Y., Wei, W., Yu, M., & Wang, P. (2019). Stability analysis of PV generators with consideration of P&O-based power control. IEEE Transactions on Industrial Electronics, 66(8), 6483-6492. doi:10.1109/TIE.2018.2864695 0278-0046 https://hdl.handle.net/10356/140499 10.1109/TIE.2018.2864695 2-s2.0-85051673728 8 66 6483 6492 en IEEE Transactions on Industrial Electronics © 2018 IEEE. All rights reserved. |
institution |
Nanyang Technological University |
building |
NTU Library |
country |
Singapore |
collection |
DR-NTU |
language |
English |
topic |
Engineering::Electrical and electronic engineering Describing Function (DF) Perturbation And Observation (P&O) Method |
spellingShingle |
Engineering::Electrical and electronic engineering Describing Function (DF) Perturbation And Observation (P&O) Method Xia, Yanghong Wei, Wei Yu, Miao Wang, Peng Stability analysis of PV generators with consideration of P&O-based power control |
description |
Photovoltaic (PV) generators have continuously increased in recent years, whose power is usually controlled through the perturbation and observation (P&O) method. In essence, the P&O method is nonlinear and discontinuous. Hence, the conventional small-signal stability analysis is not suitable anymore when the influence of the P&O-based power control is considered. Focusing on this problem, this paper adopts the nonlinear describing function (DF) method to conduct the accurate stability analysis of PV generators with consideration of P&O-based power control. The detailed procedures about the DF method are introduced, and then the related influence factors like perturbation size, filters, and so on are analyzed quantitatively. Furthermore, the comparison with the conventional stability analysis methods is made, which suggests that the DF method can effectively enhance the accuracy of the stability analysis. All the conclusions are verified by the real-time hardware-in-loop tests. |
author2 |
School of Electrical and Electronic Engineering |
author_facet |
School of Electrical and Electronic Engineering Xia, Yanghong Wei, Wei Yu, Miao Wang, Peng |
format |
Article |
author |
Xia, Yanghong Wei, Wei Yu, Miao Wang, Peng |
author_sort |
Xia, Yanghong |
title |
Stability analysis of PV generators with consideration of P&O-based power control |
title_short |
Stability analysis of PV generators with consideration of P&O-based power control |
title_full |
Stability analysis of PV generators with consideration of P&O-based power control |
title_fullStr |
Stability analysis of PV generators with consideration of P&O-based power control |
title_full_unstemmed |
Stability analysis of PV generators with consideration of P&O-based power control |
title_sort |
stability analysis of pv generators with consideration of p&o-based power control |
publishDate |
2020 |
url |
https://hdl.handle.net/10356/140499 |
_version_ |
1681058244479418368 |