Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid

CLLC-type dc transformer (CLLC-DCT) is very popular in the hybrid ac-dc microgrid thanks to its high-power density advantage and good bidirectional power transfer capacity. In the hybrid ac/dc microgrid, the open-loop control is always utilized by the CLLC-DCT to cooperate with the bidirectional int...

Full description

Saved in:
Bibliographic Details
Main Authors: Huang, Jingjing, Zhang, Xin, Shuai, Zhikang, Zhang, Xinan, Wang, Peng, Koh, Leong Hai, Xiao, Jianfang, Tong, Xiangqian
Other Authors: School of Electrical and Electronic Engineering
Format: Article
Language:English
Published: 2020
Subjects:
Online Access:https://hdl.handle.net/10356/140501
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-140501
record_format dspace
spelling sg-ntu-dr.10356-1405012020-05-29T09:03:01Z Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid Huang, Jingjing Zhang, Xin Shuai, Zhikang Zhang, Xinan Wang, Peng Koh, Leong Hai Xiao, Jianfang Tong, Xiangqian School of Electrical and Electronic Engineering Energetics Research Institute Engineering::Electrical and electronic engineering CLLC DC Transformer CLLC-type dc transformer (CLLC-DCT) is very popular in the hybrid ac-dc microgrid thanks to its high-power density advantage and good bidirectional power transfer capacity. In the hybrid ac/dc microgrid, the open-loop control is always utilized by the CLLC-DCT to cooperate with the bidirectional interlinking converter to realize the power and voltage conversion between the ac and dc bus. This paper first studies the circuit parameters design of the open-loop controlled CLLC-DCT with consideration of such a realistic problem: The real inductors/capacitors values are actually different with their theoretically designed values due to the operation power and temperature variation. To solve this problem, a robust circuit parameters design scheme is proposed for the CLLC-DCT in this paper. With the proposed scheme, the designed CLLC-DCT exhibits good power transmission and voltage regulation ability in the hybrid ac/dc microgrid even when its actual inductors/capacitors values vary with the practical power and temperature. The robust design method is experimentally verified in a hybrid ac/dc microgrid prototype. 2020-05-29T09:03:01Z 2020-05-29T09:03:01Z 2018 Journal Article Huang, J., Zhang, X., Shuai, Z., Zhang, X., Wang, P., Koh, L. H., . . . Tong, X. (2019). Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid. IEEE Transactions on Industrial Electronics, 66(3), 1906-1918. doi:10.1109/TIE.2018.2835373 0278-0046 https://hdl.handle.net/10356/140501 10.1109/TIE.2018.2835373 2-s2.0-85046790426 3 66 1906 1918 en IEEE Transactions on Industrial Electronics © 2018 IEEE. All rights reserved.
institution Nanyang Technological University
building NTU Library
country Singapore
collection DR-NTU
language English
topic Engineering::Electrical and electronic engineering
CLLC
DC Transformer
spellingShingle Engineering::Electrical and electronic engineering
CLLC
DC Transformer
Huang, Jingjing
Zhang, Xin
Shuai, Zhikang
Zhang, Xinan
Wang, Peng
Koh, Leong Hai
Xiao, Jianfang
Tong, Xiangqian
Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid
description CLLC-type dc transformer (CLLC-DCT) is very popular in the hybrid ac-dc microgrid thanks to its high-power density advantage and good bidirectional power transfer capacity. In the hybrid ac/dc microgrid, the open-loop control is always utilized by the CLLC-DCT to cooperate with the bidirectional interlinking converter to realize the power and voltage conversion between the ac and dc bus. This paper first studies the circuit parameters design of the open-loop controlled CLLC-DCT with consideration of such a realistic problem: The real inductors/capacitors values are actually different with their theoretically designed values due to the operation power and temperature variation. To solve this problem, a robust circuit parameters design scheme is proposed for the CLLC-DCT in this paper. With the proposed scheme, the designed CLLC-DCT exhibits good power transmission and voltage regulation ability in the hybrid ac/dc microgrid even when its actual inductors/capacitors values vary with the practical power and temperature. The robust design method is experimentally verified in a hybrid ac/dc microgrid prototype.
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Huang, Jingjing
Zhang, Xin
Shuai, Zhikang
Zhang, Xinan
Wang, Peng
Koh, Leong Hai
Xiao, Jianfang
Tong, Xiangqian
format Article
author Huang, Jingjing
Zhang, Xin
Shuai, Zhikang
Zhang, Xinan
Wang, Peng
Koh, Leong Hai
Xiao, Jianfang
Tong, Xiangqian
author_sort Huang, Jingjing
title Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid
title_short Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid
title_full Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid
title_fullStr Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid
title_full_unstemmed Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid
title_sort robust circuit parameters design for the cllc-type dc transformer in the hybrid ac-dc microgrid
publishDate 2020
url https://hdl.handle.net/10356/140501
_version_ 1681059705696288768