Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid
CLLC-type dc transformer (CLLC-DCT) is very popular in the hybrid ac-dc microgrid thanks to its high-power density advantage and good bidirectional power transfer capacity. In the hybrid ac/dc microgrid, the open-loop control is always utilized by the CLLC-DCT to cooperate with the bidirectional int...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2020
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/140501 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-140501 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1405012020-05-29T09:03:01Z Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid Huang, Jingjing Zhang, Xin Shuai, Zhikang Zhang, Xinan Wang, Peng Koh, Leong Hai Xiao, Jianfang Tong, Xiangqian School of Electrical and Electronic Engineering Energetics Research Institute Engineering::Electrical and electronic engineering CLLC DC Transformer CLLC-type dc transformer (CLLC-DCT) is very popular in the hybrid ac-dc microgrid thanks to its high-power density advantage and good bidirectional power transfer capacity. In the hybrid ac/dc microgrid, the open-loop control is always utilized by the CLLC-DCT to cooperate with the bidirectional interlinking converter to realize the power and voltage conversion between the ac and dc bus. This paper first studies the circuit parameters design of the open-loop controlled CLLC-DCT with consideration of such a realistic problem: The real inductors/capacitors values are actually different with their theoretically designed values due to the operation power and temperature variation. To solve this problem, a robust circuit parameters design scheme is proposed for the CLLC-DCT in this paper. With the proposed scheme, the designed CLLC-DCT exhibits good power transmission and voltage regulation ability in the hybrid ac/dc microgrid even when its actual inductors/capacitors values vary with the practical power and temperature. The robust design method is experimentally verified in a hybrid ac/dc microgrid prototype. 2020-05-29T09:03:01Z 2020-05-29T09:03:01Z 2018 Journal Article Huang, J., Zhang, X., Shuai, Z., Zhang, X., Wang, P., Koh, L. H., . . . Tong, X. (2019). Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid. IEEE Transactions on Industrial Electronics, 66(3), 1906-1918. doi:10.1109/TIE.2018.2835373 0278-0046 https://hdl.handle.net/10356/140501 10.1109/TIE.2018.2835373 2-s2.0-85046790426 3 66 1906 1918 en IEEE Transactions on Industrial Electronics © 2018 IEEE. All rights reserved. |
institution |
Nanyang Technological University |
building |
NTU Library |
country |
Singapore |
collection |
DR-NTU |
language |
English |
topic |
Engineering::Electrical and electronic engineering CLLC DC Transformer |
spellingShingle |
Engineering::Electrical and electronic engineering CLLC DC Transformer Huang, Jingjing Zhang, Xin Shuai, Zhikang Zhang, Xinan Wang, Peng Koh, Leong Hai Xiao, Jianfang Tong, Xiangqian Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid |
description |
CLLC-type dc transformer (CLLC-DCT) is very popular in the hybrid ac-dc microgrid thanks to its high-power density advantage and good bidirectional power transfer capacity. In the hybrid ac/dc microgrid, the open-loop control is always utilized by the CLLC-DCT to cooperate with the bidirectional interlinking converter to realize the power and voltage conversion between the ac and dc bus. This paper first studies the circuit parameters design of the open-loop controlled CLLC-DCT with consideration of such a realistic problem: The real inductors/capacitors values are actually different with their theoretically designed values due to the operation power and temperature variation. To solve this problem, a robust circuit parameters design scheme is proposed for the CLLC-DCT in this paper. With the proposed scheme, the designed CLLC-DCT exhibits good power transmission and voltage regulation ability in the hybrid ac/dc microgrid even when its actual inductors/capacitors values vary with the practical power and temperature. The robust design method is experimentally verified in a hybrid ac/dc microgrid prototype. |
author2 |
School of Electrical and Electronic Engineering |
author_facet |
School of Electrical and Electronic Engineering Huang, Jingjing Zhang, Xin Shuai, Zhikang Zhang, Xinan Wang, Peng Koh, Leong Hai Xiao, Jianfang Tong, Xiangqian |
format |
Article |
author |
Huang, Jingjing Zhang, Xin Shuai, Zhikang Zhang, Xinan Wang, Peng Koh, Leong Hai Xiao, Jianfang Tong, Xiangqian |
author_sort |
Huang, Jingjing |
title |
Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid |
title_short |
Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid |
title_full |
Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid |
title_fullStr |
Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid |
title_full_unstemmed |
Robust circuit parameters design for the CLLC-type DC transformer in the hybrid AC-DC microgrid |
title_sort |
robust circuit parameters design for the cllc-type dc transformer in the hybrid ac-dc microgrid |
publishDate |
2020 |
url |
https://hdl.handle.net/10356/140501 |
_version_ |
1681059705696288768 |