Quantification of capsaicinoids in chillies by solid-phase extraction coupled with voltammetry

Capsaicinoids were extracted from a range of spices and chillies using methanol, prior to concentrating the compounds using solid-phase extraction cartridges and water/methanol (50:50% v/v) as the solvent, followed by elution with acetonitrile. The primary extraction procedure, involving only sonica...

Full description

Saved in:
Bibliographic Details
Main Authors: Chan, Kwok Kiong, Muhammad Shafique Bin Hamid, Webster, Richard David
Other Authors: School of Physical and Mathematical Sciences
Format: Article
Language:English
Published: 2020
Subjects:
Online Access:https://hdl.handle.net/10356/140860
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-140860
record_format dspace
spelling sg-ntu-dr.10356-1408602020-06-02T08:33:25Z Quantification of capsaicinoids in chillies by solid-phase extraction coupled with voltammetry Chan, Kwok Kiong Muhammad Shafique Bin Hamid Webster, Richard David School of Physical and Mathematical Sciences Science::Chemistry Chilli Square-wave Voltammetry Capsaicinoids were extracted from a range of spices and chillies using methanol, prior to concentrating the compounds using solid-phase extraction cartridges and water/methanol (50:50% v/v) as the solvent, followed by elution with acetonitrile. The primary extraction procedure, involving only sonication of the spices in methanol, gave results comparable to a procedure that used a combination of sonication, stirring and centrifuging. The voltammetric quantification of the capsaicinoids, at approximately +0.5 V vs. ferrocene0/+ that were transferred from methanol/water into acetonitrile/water via solid phase extraction, was carried out in microcentrifuge tubes. Linear calibration curves for voltammetry measurements were obtained from low ppm up to at least 1400 ppm of capsaicinoids, with concentrations being detected in the different source extracts (paprika, tabasco sauce, cayenne pepper, and fresh chillies) from approximately 17 to 430 ppm, which corresponded to values of between approximately 130 and 4000 ppm, respectively, present in the original samples. NRF (Natl Research Foundation, S’pore) MOE (Min. of Education, S’pore) 2020-06-02T08:33:25Z 2020-06-02T08:33:25Z 2018 Journal Article Chan, K. K., Muhammad Shafique Hamid, & Webster, R. D. (2018). Quantification of capsaicinoids in chillies by solid-phase extraction coupled with voltammetry. Food Chemistry, 265, 152-158. doi:10.1016/j.foodchem.2018.05.069 0308-8146 https://hdl.handle.net/10356/140860 10.1016/j.foodchem.2018.05.069 29884366 2-s2.0-85047265876 265 152 158 en Food Chemistry © 2018 Elsevier Ltd. All rights reserved.
institution Nanyang Technological University
building NTU Library
country Singapore
collection DR-NTU
language English
topic Science::Chemistry
Chilli
Square-wave Voltammetry
spellingShingle Science::Chemistry
Chilli
Square-wave Voltammetry
Chan, Kwok Kiong
Muhammad Shafique Bin Hamid
Webster, Richard David
Quantification of capsaicinoids in chillies by solid-phase extraction coupled with voltammetry
description Capsaicinoids were extracted from a range of spices and chillies using methanol, prior to concentrating the compounds using solid-phase extraction cartridges and water/methanol (50:50% v/v) as the solvent, followed by elution with acetonitrile. The primary extraction procedure, involving only sonication of the spices in methanol, gave results comparable to a procedure that used a combination of sonication, stirring and centrifuging. The voltammetric quantification of the capsaicinoids, at approximately +0.5 V vs. ferrocene0/+ that were transferred from methanol/water into acetonitrile/water via solid phase extraction, was carried out in microcentrifuge tubes. Linear calibration curves for voltammetry measurements were obtained from low ppm up to at least 1400 ppm of capsaicinoids, with concentrations being detected in the different source extracts (paprika, tabasco sauce, cayenne pepper, and fresh chillies) from approximately 17 to 430 ppm, which corresponded to values of between approximately 130 and 4000 ppm, respectively, present in the original samples.
author2 School of Physical and Mathematical Sciences
author_facet School of Physical and Mathematical Sciences
Chan, Kwok Kiong
Muhammad Shafique Bin Hamid
Webster, Richard David
format Article
author Chan, Kwok Kiong
Muhammad Shafique Bin Hamid
Webster, Richard David
author_sort Chan, Kwok Kiong
title Quantification of capsaicinoids in chillies by solid-phase extraction coupled with voltammetry
title_short Quantification of capsaicinoids in chillies by solid-phase extraction coupled with voltammetry
title_full Quantification of capsaicinoids in chillies by solid-phase extraction coupled with voltammetry
title_fullStr Quantification of capsaicinoids in chillies by solid-phase extraction coupled with voltammetry
title_full_unstemmed Quantification of capsaicinoids in chillies by solid-phase extraction coupled with voltammetry
title_sort quantification of capsaicinoids in chillies by solid-phase extraction coupled with voltammetry
publishDate 2020
url https://hdl.handle.net/10356/140860
_version_ 1681059518327291904