Enhanced immersion two-phase liquid cooling thermal management for data centres

The present study aims to develop and investigate the uprising trend of cooling method. Two phase liquid immersion cooling is the state-of-the-art cooling methodology that is garnering increasing attention in the data centres industry. This contemporary method of cooling can reshape the data centre...

Full description

Saved in:
Bibliographic Details
Main Author: Loh, Aloysius Chuan Liang
Other Authors: Fei Duan
Format: Final Year Project
Language:English
Published: Nanyang Technological University 2020
Subjects:
Online Access:https://hdl.handle.net/10356/141013
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-141013
record_format dspace
spelling sg-ntu-dr.10356-1410132023-03-04T19:28:45Z Enhanced immersion two-phase liquid cooling thermal management for data centres Loh, Aloysius Chuan Liang Fei Duan School of Mechanical and Aerospace Engineering FeiDuan@ntu.edu.sg Engineering::Mechanical engineering The present study aims to develop and investigate the uprising trend of cooling method. Two phase liquid immersion cooling is the state-of-the-art cooling methodology that is garnering increasing attention in the data centres industry. This contemporary method of cooling can reshape the data centre industry if proven to be more effective than air cooling, the commonly employed method of cooling for data centres at present. Unlike its predecessors, this method of cooling is self-sufficient and self-reliant theoretically. It means that it can run on its own without much human intervention. By utilising simple concepts of evaporation and condensation, the cooling method can reduce the amount of coolant used over a long period of time. This unique way of cooling requires a tank in a sealed condition. It creates a closed loop system. In addition, it eliminates the need for chillers. Consequently, it can dramatically reduce the electrical consumption of data centres. In this study, a two-phase immersion cooling tank was managed to design required to hold the necessary equipment and components for the experiments. Subsequently, the in-depth research and data collection were made before concluding on the working fluid to be employed for the experiments. Furthermore, the different types of experiments were conducted, and the crucial data were collected to prove the effectiveness of two-phase liquid immersion cooling. The experiments, which utilises air cooling and two-phase liquid immersion cooling, revolve around changing the temperatures of the either the water running through the condenser coils or changing the working capacity of the CPUs. From these results, the analysis was conducted on the different types of cooling before drawing the conclusions. Future works are suggested to improve the two-phase immersion cooling system. Bachelor of Engineering (Mechanical Engineering) 2020-06-03T07:14:21Z 2020-06-03T07:14:21Z 2020 Final Year Project (FYP) https://hdl.handle.net/10356/141013 en A059 application/pdf Nanyang Technological University
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Mechanical engineering
spellingShingle Engineering::Mechanical engineering
Loh, Aloysius Chuan Liang
Enhanced immersion two-phase liquid cooling thermal management for data centres
description The present study aims to develop and investigate the uprising trend of cooling method. Two phase liquid immersion cooling is the state-of-the-art cooling methodology that is garnering increasing attention in the data centres industry. This contemporary method of cooling can reshape the data centre industry if proven to be more effective than air cooling, the commonly employed method of cooling for data centres at present. Unlike its predecessors, this method of cooling is self-sufficient and self-reliant theoretically. It means that it can run on its own without much human intervention. By utilising simple concepts of evaporation and condensation, the cooling method can reduce the amount of coolant used over a long period of time. This unique way of cooling requires a tank in a sealed condition. It creates a closed loop system. In addition, it eliminates the need for chillers. Consequently, it can dramatically reduce the electrical consumption of data centres. In this study, a two-phase immersion cooling tank was managed to design required to hold the necessary equipment and components for the experiments. Subsequently, the in-depth research and data collection were made before concluding on the working fluid to be employed for the experiments. Furthermore, the different types of experiments were conducted, and the crucial data were collected to prove the effectiveness of two-phase liquid immersion cooling. The experiments, which utilises air cooling and two-phase liquid immersion cooling, revolve around changing the temperatures of the either the water running through the condenser coils or changing the working capacity of the CPUs. From these results, the analysis was conducted on the different types of cooling before drawing the conclusions. Future works are suggested to improve the two-phase immersion cooling system.
author2 Fei Duan
author_facet Fei Duan
Loh, Aloysius Chuan Liang
format Final Year Project
author Loh, Aloysius Chuan Liang
author_sort Loh, Aloysius Chuan Liang
title Enhanced immersion two-phase liquid cooling thermal management for data centres
title_short Enhanced immersion two-phase liquid cooling thermal management for data centres
title_full Enhanced immersion two-phase liquid cooling thermal management for data centres
title_fullStr Enhanced immersion two-phase liquid cooling thermal management for data centres
title_full_unstemmed Enhanced immersion two-phase liquid cooling thermal management for data centres
title_sort enhanced immersion two-phase liquid cooling thermal management for data centres
publisher Nanyang Technological University
publishDate 2020
url https://hdl.handle.net/10356/141013
_version_ 1759857960260993024