An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters
This paper presents a model-based open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped (3LNPC) converters in electric railway application. The diagnosis algorithm, which only requires the signals existing in the control system, not only detects open-circuit faults...
Saved in:
Main Authors: | , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2020
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/141605 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-141605 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1416052020-06-09T07:22:20Z An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters Ge, Xinglai Pu, Junkai Gou, Bin Liu, Yong-Chao School of Electrical and Electronic Engineering Engineering::Electrical and electronic engineering Fault Diagnosis Mixed Logical Dynamic (MLD) This paper presents a model-based open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped (3LNPC) converters in electric railway application. The diagnosis algorithm, which only requires the signals existing in the control system, not only detects open-circuit faults but also identifies the faulty device among the transistors and clamping diodes. The mixed logical dynamic (MLD) model of the converter is built to estimate the grid current. The residual generated from the measured current subtracting the estimated one is analyzed under different open-circuit faults. According to the characteristics of the residual changing rate, the proposed approach allows fault localization. The proposed method is effective both in traction and regenerative braking operation and has fast diagnosis speed. Hardware-in-the-loop (HIL) experiments are carried out to verify the effectiveness of the proposed fault diagnosis algorithm. 2020-06-09T07:22:20Z 2020-06-09T07:22:20Z 2017 Journal Article Ge, X., Pu, J., Gou, B., & Liu, Y.-C. (2018). An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters. IEEE Transactions on Power Electronics, 33(3), 2559-2570. doi:10.1109/TPEL.2017.2691804 0885-8993 https://hdl.handle.net/10356/141605 10.1109/TPEL.2017.2691804 2-s2.0-85038898065 3 33 2559 2570 en IEEE Transactions on Power Electronics © 2017 IEEE. All rights reserved. |
institution |
Nanyang Technological University |
building |
NTU Library |
country |
Singapore |
collection |
DR-NTU |
language |
English |
topic |
Engineering::Electrical and electronic engineering Fault Diagnosis Mixed Logical Dynamic (MLD) |
spellingShingle |
Engineering::Electrical and electronic engineering Fault Diagnosis Mixed Logical Dynamic (MLD) Ge, Xinglai Pu, Junkai Gou, Bin Liu, Yong-Chao An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters |
description |
This paper presents a model-based open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped (3LNPC) converters in electric railway application. The diagnosis algorithm, which only requires the signals existing in the control system, not only detects open-circuit faults but also identifies the faulty device among the transistors and clamping diodes. The mixed logical dynamic (MLD) model of the converter is built to estimate the grid current. The residual generated from the measured current subtracting the estimated one is analyzed under different open-circuit faults. According to the characteristics of the residual changing rate, the proposed approach allows fault localization. The proposed method is effective both in traction and regenerative braking operation and has fast diagnosis speed. Hardware-in-the-loop (HIL) experiments are carried out to verify the effectiveness of the proposed fault diagnosis algorithm. |
author2 |
School of Electrical and Electronic Engineering |
author_facet |
School of Electrical and Electronic Engineering Ge, Xinglai Pu, Junkai Gou, Bin Liu, Yong-Chao |
format |
Article |
author |
Ge, Xinglai Pu, Junkai Gou, Bin Liu, Yong-Chao |
author_sort |
Ge, Xinglai |
title |
An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters |
title_short |
An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters |
title_full |
An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters |
title_fullStr |
An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters |
title_full_unstemmed |
An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters |
title_sort |
open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters |
publishDate |
2020 |
url |
https://hdl.handle.net/10356/141605 |
_version_ |
1681057173741764608 |