An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters

This paper presents a model-based open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped (3LNPC) converters in electric railway application. The diagnosis algorithm, which only requires the signals existing in the control system, not only detects open-circuit faults...

Full description

Saved in:
Bibliographic Details
Main Authors: Ge, Xinglai, Pu, Junkai, Gou, Bin, Liu, Yong-Chao
Other Authors: School of Electrical and Electronic Engineering
Format: Article
Language:English
Published: 2020
Subjects:
Online Access:https://hdl.handle.net/10356/141605
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-141605
record_format dspace
spelling sg-ntu-dr.10356-1416052020-06-09T07:22:20Z An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters Ge, Xinglai Pu, Junkai Gou, Bin Liu, Yong-Chao School of Electrical and Electronic Engineering Engineering::Electrical and electronic engineering Fault Diagnosis Mixed Logical Dynamic (MLD) This paper presents a model-based open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped (3LNPC) converters in electric railway application. The diagnosis algorithm, which only requires the signals existing in the control system, not only detects open-circuit faults but also identifies the faulty device among the transistors and clamping diodes. The mixed logical dynamic (MLD) model of the converter is built to estimate the grid current. The residual generated from the measured current subtracting the estimated one is analyzed under different open-circuit faults. According to the characteristics of the residual changing rate, the proposed approach allows fault localization. The proposed method is effective both in traction and regenerative braking operation and has fast diagnosis speed. Hardware-in-the-loop (HIL) experiments are carried out to verify the effectiveness of the proposed fault diagnosis algorithm. 2020-06-09T07:22:20Z 2020-06-09T07:22:20Z 2017 Journal Article Ge, X., Pu, J., Gou, B., & Liu, Y.-C. (2018). An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters. IEEE Transactions on Power Electronics, 33(3), 2559-2570. doi:10.1109/TPEL.2017.2691804 0885-8993 https://hdl.handle.net/10356/141605 10.1109/TPEL.2017.2691804 2-s2.0-85038898065 3 33 2559 2570 en IEEE Transactions on Power Electronics © 2017 IEEE. All rights reserved.
institution Nanyang Technological University
building NTU Library
country Singapore
collection DR-NTU
language English
topic Engineering::Electrical and electronic engineering
Fault Diagnosis
Mixed Logical Dynamic (MLD)
spellingShingle Engineering::Electrical and electronic engineering
Fault Diagnosis
Mixed Logical Dynamic (MLD)
Ge, Xinglai
Pu, Junkai
Gou, Bin
Liu, Yong-Chao
An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters
description This paper presents a model-based open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped (3LNPC) converters in electric railway application. The diagnosis algorithm, which only requires the signals existing in the control system, not only detects open-circuit faults but also identifies the faulty device among the transistors and clamping diodes. The mixed logical dynamic (MLD) model of the converter is built to estimate the grid current. The residual generated from the measured current subtracting the estimated one is analyzed under different open-circuit faults. According to the characteristics of the residual changing rate, the proposed approach allows fault localization. The proposed method is effective both in traction and regenerative braking operation and has fast diagnosis speed. Hardware-in-the-loop (HIL) experiments are carried out to verify the effectiveness of the proposed fault diagnosis algorithm.
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Ge, Xinglai
Pu, Junkai
Gou, Bin
Liu, Yong-Chao
format Article
author Ge, Xinglai
Pu, Junkai
Gou, Bin
Liu, Yong-Chao
author_sort Ge, Xinglai
title An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters
title_short An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters
title_full An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters
title_fullStr An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters
title_full_unstemmed An open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters
title_sort open-circuit fault diagnosis approach for single-phase three-level neutral-point-clamped converters
publishDate 2020
url https://hdl.handle.net/10356/141605
_version_ 1681057173741764608