Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia

Purpose: To investigate the repeatability and reproducibility of the Visante Omni topography in obtaining topography measurements of rabbit corneas and to develop a post-surgical model of corneal ectasia. Methods: Eight rabbits were used to study the repeatability and reproducibility by assessing th...

Full description

Saved in:
Bibliographic Details
Main Authors: Liu, Yu-Chi, Konstantopoulos, Aris, Riau, Andri K., Bhayani, Raj, Lwin, Nyein C., Teo, Ericia Pei Wen, Yam, Gary Hin Fai, Mehta, Jodhbir Singh
Other Authors: School of Materials Science and Engineering
Format: Article
Language:English
Published: 2020
Subjects:
Online Access:https://hdl.handle.net/10356/142138
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-142138
record_format dspace
spelling sg-ntu-dr.10356-1421382023-07-14T15:47:38Z Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia Liu, Yu-Chi Konstantopoulos, Aris Riau, Andri K. Bhayani, Raj Lwin, Nyein C. Teo, Ericia Pei Wen Yam, Gary Hin Fai Mehta, Jodhbir Singh School of Materials Science and Engineering School of Mechanical and Aerospace Engineering Engineering::Materials Corneal Ectasia Visante Omni Topography Purpose: To investigate the repeatability and reproducibility of the Visante Omni topography in obtaining topography measurements of rabbit corneas and to develop a post-surgical model of corneal ectasia. Methods: Eight rabbits were used to study the repeatability and reproducibility by assessing the intra- and interobserver bias and limits of agreement. Another nine rabbits underwent different diopters (D) of laser in situ keratosmileusis (LASIK) were used for the development of ectasia model. All eyes were examined with the Visante Omni, and corneal ultrastructure were evaluated with transmission electron microscopy (TEM). Results: There was no significant intra- or interobserver difference for mean steep and flat keratometry (K) values of simulated K, anterior, and posterior elevation measurements. Eyes underwent -5 D LASIK had a significant increase in mean amplitude of astigmatism and posterior surface elevation with time (P for trend < 0.05). At 2 and 3 months, the -5 D LASIK group had significant greater mean amplitude of astigmatism (P = 0.036; P = 0.027) and posterior surface elevation (both P < 0.005) compared with control group. On TEM, the mean collagen fibril diameter and interfibril distance in the -5 D LASIK eyes were significantly greater than in controls at 3 months (P = 0.018; P < 0.001). Conclusions: The Visante Omni provided imaging of the rabbit cornea with good repeatability and reproducibility. Application of -5 D LASIK treatment produced a rabbit model of corneal ectasia that was gradual in development and simulated the human condition. Translational Relevance: The results provide the foundations for the future evaluation of novel treatment modalities for post-surgical ectasia and keratoconus. NRF (Natl Research Foundation, S’pore) NMRC (Natl Medical Research Council, S’pore) MOH (Min. of Health, S’pore) Published version 2020-06-16T05:43:33Z 2020-06-16T05:43:33Z 2015 Journal Article Liu, Y.-C., Konstantopoulos, A., Riau, A. K., Bhayani, R., Lwin, N. C., Teo, E. P. W., . . . Mehta, J. S. (2015). Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia. Translational Vision Science & Technology, 4(2), 16-. doi:10.1167/tvst.4.2.16 2164-2591 https://hdl.handle.net/10356/142138 10.1167/tvst.4.2.16 25938004 2-s2.0-85043636220 2 4 en Translational Vision Science & Technology © 2015 Association for Research in Vision and Ophthalmology (ARVO). All rights reserved. This paper was published in Translational Vision Science & Technology and is made available with permission of Association for Research in Vision and Ophthalmology (ARVO). application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Materials
Corneal Ectasia
Visante Omni Topography
spellingShingle Engineering::Materials
Corneal Ectasia
Visante Omni Topography
Liu, Yu-Chi
Konstantopoulos, Aris
Riau, Andri K.
Bhayani, Raj
Lwin, Nyein C.
Teo, Ericia Pei Wen
Yam, Gary Hin Fai
Mehta, Jodhbir Singh
Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia
description Purpose: To investigate the repeatability and reproducibility of the Visante Omni topography in obtaining topography measurements of rabbit corneas and to develop a post-surgical model of corneal ectasia. Methods: Eight rabbits were used to study the repeatability and reproducibility by assessing the intra- and interobserver bias and limits of agreement. Another nine rabbits underwent different diopters (D) of laser in situ keratosmileusis (LASIK) were used for the development of ectasia model. All eyes were examined with the Visante Omni, and corneal ultrastructure were evaluated with transmission electron microscopy (TEM). Results: There was no significant intra- or interobserver difference for mean steep and flat keratometry (K) values of simulated K, anterior, and posterior elevation measurements. Eyes underwent -5 D LASIK had a significant increase in mean amplitude of astigmatism and posterior surface elevation with time (P for trend < 0.05). At 2 and 3 months, the -5 D LASIK group had significant greater mean amplitude of astigmatism (P = 0.036; P = 0.027) and posterior surface elevation (both P < 0.005) compared with control group. On TEM, the mean collagen fibril diameter and interfibril distance in the -5 D LASIK eyes were significantly greater than in controls at 3 months (P = 0.018; P < 0.001). Conclusions: The Visante Omni provided imaging of the rabbit cornea with good repeatability and reproducibility. Application of -5 D LASIK treatment produced a rabbit model of corneal ectasia that was gradual in development and simulated the human condition. Translational Relevance: The results provide the foundations for the future evaluation of novel treatment modalities for post-surgical ectasia and keratoconus.
author2 School of Materials Science and Engineering
author_facet School of Materials Science and Engineering
Liu, Yu-Chi
Konstantopoulos, Aris
Riau, Andri K.
Bhayani, Raj
Lwin, Nyein C.
Teo, Ericia Pei Wen
Yam, Gary Hin Fai
Mehta, Jodhbir Singh
format Article
author Liu, Yu-Chi
Konstantopoulos, Aris
Riau, Andri K.
Bhayani, Raj
Lwin, Nyein C.
Teo, Ericia Pei Wen
Yam, Gary Hin Fai
Mehta, Jodhbir Singh
author_sort Liu, Yu-Chi
title Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia
title_short Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia
title_full Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia
title_fullStr Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia
title_full_unstemmed Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia
title_sort repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia
publishDate 2020
url https://hdl.handle.net/10356/142138
_version_ 1772828491328258048