Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia
Purpose: To investigate the repeatability and reproducibility of the Visante Omni topography in obtaining topography measurements of rabbit corneas and to develop a post-surgical model of corneal ectasia. Methods: Eight rabbits were used to study the repeatability and reproducibility by assessing th...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2020
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/142138 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-142138 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1421382023-07-14T15:47:38Z Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia Liu, Yu-Chi Konstantopoulos, Aris Riau, Andri K. Bhayani, Raj Lwin, Nyein C. Teo, Ericia Pei Wen Yam, Gary Hin Fai Mehta, Jodhbir Singh School of Materials Science and Engineering School of Mechanical and Aerospace Engineering Engineering::Materials Corneal Ectasia Visante Omni Topography Purpose: To investigate the repeatability and reproducibility of the Visante Omni topography in obtaining topography measurements of rabbit corneas and to develop a post-surgical model of corneal ectasia. Methods: Eight rabbits were used to study the repeatability and reproducibility by assessing the intra- and interobserver bias and limits of agreement. Another nine rabbits underwent different diopters (D) of laser in situ keratosmileusis (LASIK) were used for the development of ectasia model. All eyes were examined with the Visante Omni, and corneal ultrastructure were evaluated with transmission electron microscopy (TEM). Results: There was no significant intra- or interobserver difference for mean steep and flat keratometry (K) values of simulated K, anterior, and posterior elevation measurements. Eyes underwent -5 D LASIK had a significant increase in mean amplitude of astigmatism and posterior surface elevation with time (P for trend < 0.05). At 2 and 3 months, the -5 D LASIK group had significant greater mean amplitude of astigmatism (P = 0.036; P = 0.027) and posterior surface elevation (both P < 0.005) compared with control group. On TEM, the mean collagen fibril diameter and interfibril distance in the -5 D LASIK eyes were significantly greater than in controls at 3 months (P = 0.018; P < 0.001). Conclusions: The Visante Omni provided imaging of the rabbit cornea with good repeatability and reproducibility. Application of -5 D LASIK treatment produced a rabbit model of corneal ectasia that was gradual in development and simulated the human condition. Translational Relevance: The results provide the foundations for the future evaluation of novel treatment modalities for post-surgical ectasia and keratoconus. NRF (Natl Research Foundation, S’pore) NMRC (Natl Medical Research Council, S’pore) MOH (Min. of Health, S’pore) Published version 2020-06-16T05:43:33Z 2020-06-16T05:43:33Z 2015 Journal Article Liu, Y.-C., Konstantopoulos, A., Riau, A. K., Bhayani, R., Lwin, N. C., Teo, E. P. W., . . . Mehta, J. S. (2015). Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia. Translational Vision Science & Technology, 4(2), 16-. doi:10.1167/tvst.4.2.16 2164-2591 https://hdl.handle.net/10356/142138 10.1167/tvst.4.2.16 25938004 2-s2.0-85043636220 2 4 en Translational Vision Science & Technology © 2015 Association for Research in Vision and Ophthalmology (ARVO). All rights reserved. This paper was published in Translational Vision Science & Technology and is made available with permission of Association for Research in Vision and Ophthalmology (ARVO). application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
Engineering::Materials Corneal Ectasia Visante Omni Topography |
spellingShingle |
Engineering::Materials Corneal Ectasia Visante Omni Topography Liu, Yu-Chi Konstantopoulos, Aris Riau, Andri K. Bhayani, Raj Lwin, Nyein C. Teo, Ericia Pei Wen Yam, Gary Hin Fai Mehta, Jodhbir Singh Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia |
description |
Purpose: To investigate the repeatability and reproducibility of the Visante Omni topography in obtaining topography measurements of rabbit corneas and to develop a post-surgical model of corneal ectasia. Methods: Eight rabbits were used to study the repeatability and reproducibility by assessing the intra- and interobserver bias and limits of agreement. Another nine rabbits underwent different diopters (D) of laser in situ keratosmileusis (LASIK) were used for the development of ectasia model. All eyes were examined with the Visante Omni, and corneal ultrastructure were evaluated with transmission electron microscopy (TEM). Results: There was no significant intra- or interobserver difference for mean steep and flat keratometry (K) values of simulated K, anterior, and posterior elevation measurements. Eyes underwent -5 D LASIK had a significant increase in mean amplitude of astigmatism and posterior surface elevation with time (P for trend < 0.05). At 2 and 3 months, the -5 D LASIK group had significant greater mean amplitude of astigmatism (P = 0.036; P = 0.027) and posterior surface elevation (both P < 0.005) compared with control group. On TEM, the mean collagen fibril diameter and interfibril distance in the -5 D LASIK eyes were significantly greater than in controls at 3 months (P = 0.018; P < 0.001). Conclusions: The Visante Omni provided imaging of the rabbit cornea with good repeatability and reproducibility. Application of -5 D LASIK treatment produced a rabbit model of corneal ectasia that was gradual in development and simulated the human condition. Translational Relevance: The results provide the foundations for the future evaluation of novel treatment modalities for post-surgical ectasia and keratoconus. |
author2 |
School of Materials Science and Engineering |
author_facet |
School of Materials Science and Engineering Liu, Yu-Chi Konstantopoulos, Aris Riau, Andri K. Bhayani, Raj Lwin, Nyein C. Teo, Ericia Pei Wen Yam, Gary Hin Fai Mehta, Jodhbir Singh |
format |
Article |
author |
Liu, Yu-Chi Konstantopoulos, Aris Riau, Andri K. Bhayani, Raj Lwin, Nyein C. Teo, Ericia Pei Wen Yam, Gary Hin Fai Mehta, Jodhbir Singh |
author_sort |
Liu, Yu-Chi |
title |
Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia |
title_short |
Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia |
title_full |
Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia |
title_fullStr |
Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia |
title_full_unstemmed |
Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia |
title_sort |
repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia |
publishDate |
2020 |
url |
https://hdl.handle.net/10356/142138 |
_version_ |
1772828491328258048 |