Blood pressure estimation throught function approximation

Periodic health control monitoring can assist us to minimize the effect of undiscovered chronic hypertension leading to several cardiovascular diseases. Blood Pressure (BP) is an important factor to be considered as it can provide fundamental information about personal health condition of a person....

Full description

Saved in:
Bibliographic Details
Main Author: Rajendran, Chandrakala
Other Authors: Saman S Abeysekera
Format: Thesis-Master by Coursework
Language:English
Published: Nanyang Technological University 2020
Subjects:
Online Access:https://hdl.handle.net/10356/142929
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-142929
record_format dspace
spelling sg-ntu-dr.10356-1429292023-07-04T15:02:49Z Blood pressure estimation throught function approximation Rajendran, Chandrakala Saman S Abeysekera School of Electrical and Electronic Engineering Esabeysekera@ntu.edu.sg Engineering::Electrical and electronic engineering Periodic health control monitoring can assist us to minimize the effect of undiscovered chronic hypertension leading to several cardiovascular diseases. Blood Pressure (BP) is an important factor to be considered as it can provide fundamental information about personal health condition of a person. Hence it is necessary to implement a fast and easy BP measurement technique for the ease of patients anywhere, anytime. Photoplethysmography (PPG) based blood pressure measurement is more approachable due to its inexpensiveness and simplicity of measurement. It is observed that there exists a non-linear relationship between BP and time-domain features, obtained from PPG signal. This dissertation describes a new approach for estimating Systolic BP and Diastolic BP by non-invasively using PPG signal. This work involves prediction by Artificial Neural Network using modified four-element windkessel parameters obtained from photoplethysmography signal. Using MATLAB, the model is trained with input PPG parameters such as compliance of proximal C1 and distal C2 artery, total inertance L, Systolic time Ts to obtain the Systolic BP and Diastolic BP. The performance of Artificial Neural Network is compared with Shallow Neural Network and Regression by Support Vector Machine by computing the mean square error, standard deviation, mean of each machine learning model. Compared with SVM-R and SNN, the approach of ANN has better accuracy with less mean squared error, standard deviation, and mean value of SBP and DBP. Master of Science (Signal Processing) 2020-07-14T01:40:11Z 2020-07-14T01:40:11Z 2020 Thesis-Master by Coursework https://hdl.handle.net/10356/142929 en application/pdf Nanyang Technological University
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Electrical and electronic engineering
spellingShingle Engineering::Electrical and electronic engineering
Rajendran, Chandrakala
Blood pressure estimation throught function approximation
description Periodic health control monitoring can assist us to minimize the effect of undiscovered chronic hypertension leading to several cardiovascular diseases. Blood Pressure (BP) is an important factor to be considered as it can provide fundamental information about personal health condition of a person. Hence it is necessary to implement a fast and easy BP measurement technique for the ease of patients anywhere, anytime. Photoplethysmography (PPG) based blood pressure measurement is more approachable due to its inexpensiveness and simplicity of measurement. It is observed that there exists a non-linear relationship between BP and time-domain features, obtained from PPG signal. This dissertation describes a new approach for estimating Systolic BP and Diastolic BP by non-invasively using PPG signal. This work involves prediction by Artificial Neural Network using modified four-element windkessel parameters obtained from photoplethysmography signal. Using MATLAB, the model is trained with input PPG parameters such as compliance of proximal C1 and distal C2 artery, total inertance L, Systolic time Ts to obtain the Systolic BP and Diastolic BP. The performance of Artificial Neural Network is compared with Shallow Neural Network and Regression by Support Vector Machine by computing the mean square error, standard deviation, mean of each machine learning model. Compared with SVM-R and SNN, the approach of ANN has better accuracy with less mean squared error, standard deviation, and mean value of SBP and DBP.
author2 Saman S Abeysekera
author_facet Saman S Abeysekera
Rajendran, Chandrakala
format Thesis-Master by Coursework
author Rajendran, Chandrakala
author_sort Rajendran, Chandrakala
title Blood pressure estimation throught function approximation
title_short Blood pressure estimation throught function approximation
title_full Blood pressure estimation throught function approximation
title_fullStr Blood pressure estimation throught function approximation
title_full_unstemmed Blood pressure estimation throught function approximation
title_sort blood pressure estimation throught function approximation
publisher Nanyang Technological University
publishDate 2020
url https://hdl.handle.net/10356/142929
_version_ 1772827284852441088