Standardizing Monte Carlo simulation parameters for a reproducible dose-averaged linear energy transfer
Objective: Dose-averaged linear energy transfer (LETD) is one of the factors which determines relative biological effectiveness (RBE) for treatment planning in proton therapy. It is usually determined from Monte Carlo (MC) simulation. However, no standard simulation protocols were established for sa...
Saved in:
Main Authors: | , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2020
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/144097 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
Summary: | Objective: Dose-averaged linear energy transfer (LETD) is one of the factors which determines relative biological effectiveness (RBE) for treatment planning in proton therapy. It is usually determined from Monte Carlo (MC) simulation. However, no standard simulation protocols were established for sampling of LETD. Simulation parameters like maximum step length and range cut will affect secondary electrons production and have an impact on the accuracy of dose distribution and LETD. We aim to show how different combinations of step length and range cut in GEANT4 will affect the result in sampling of LETD using different MC scoring methods.
Methods: In this work, different step length and range cut value in a clinically relevant voxel geometry were
used for comparison. Different LETD scoring methods were established and the concept of covariance between energy deposition per step and step length is used to explain the differences between them.
Results: We recommend a maximum step length of 0.05 mm and a range cut of 0.01 mm in MC simulation
as this yields the most consistent LETD value across different scoring methods. Different LETD scoring
methods are also compared and variation up to 200% can be observed at the plateau of 80 MeV proton beam.
Scoring Method one has one of the lowest percentage differences compared across all simulation parameters.
Conclusion: We have determined a set of maximum step length and range cut parameters to be used for LETD
scoring in a 1 mm voxelized geometry. LETD scoring method should also be clearly defined and standardized
to facilitate cross-institutional studies.
Advances in knowledge: Establishing a standard simulation protocol for sampling LETD would reduce the
discrepancy when comparing data across different centres, and this can improve the calculation for RBE. |
---|