Noninvasive and noncontact sequential imaging of the iridocorneal angle and the cornea of the eye
High-resolution imaging of the critical anatomic structures of the eye, especially of the anterior chamber, in vivo, remains a challenge, even with currently available state-of-the-art medical imaging techniques. This study aims for the noninvasive and noncontact sequential imaging of the iridocorne...
Saved in:
Main Authors: | , , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2020
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/144178 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-144178 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1441782023-03-04T17:23:35Z Noninvasive and noncontact sequential imaging of the iridocorneal angle and the cornea of the eye Hong, Jeesmond Xun Jie Suchand Sandeep, Chandramathi Sukumaran Shinoj, Vengalathunadakal Kuttinarayan Aung, Tin Barathi, Veluchamy Amutha Baskaran, Mani Murukeshan, Vadakke Matham School of Mechanical and Aerospace Engineering Engineering::Mechanical engineering Imaging Method Translational Research High-resolution imaging of the critical anatomic structures of the eye, especially of the anterior chamber, in vivo, remains a challenge, even with currently available state-of-the-art medical imaging techniques. This study aims for the noninvasive and noncontact sequential imaging of the iridocorneal angle, especially the trabecular meshwork (TM) and the cornea of the eye in high-resolution using a newly developed imaging platform. Agency for Science, Technology and Research (A*STAR) National Medical Research Council (NMRC) Published version The authors acknowledge financial support received through A*STAR-MIG project (BMRC1619077002), NMRC Transition Award (NMRC/TA/0040/2015), and A*STAR-SERC grant (1121480003) for pursuing part of the contents presented in this article, and the research manpower and facilities provided through COLE-EDB funding at COLE, NTU. This research is also supported by the Singapore Ministry of Health’s National Medical Research Council under its NMRC Centre Grant (CG-Imaging) Programme (NMRC/CG/C010A/2017/PreClinical). 2020-10-19T09:10:15Z 2020-10-19T09:10:15Z 2020 Journal Article Hong, J. X. J., Suchand Sandeep, C. S., Shinoj, V. K., Aung, T., Barathi, V. A., Baskaran, M., & Murukeshan, V. M. (2020). Noninvasive and noncontact sequential imaging of the iridocorneal angle and the cornea of the eye. Translational Vision Science & Technology, 9(5), 1-14. doi:10.1167/tvst.9.5.1 2164-2591 https://hdl.handle.net/10356/144178 10.1167/tvst.9.5.1 32821473 5 9 1 14 en Translational Vision Science & Technology © 2020 The Authors. This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
Engineering::Mechanical engineering Imaging Method Translational Research |
spellingShingle |
Engineering::Mechanical engineering Imaging Method Translational Research Hong, Jeesmond Xun Jie Suchand Sandeep, Chandramathi Sukumaran Shinoj, Vengalathunadakal Kuttinarayan Aung, Tin Barathi, Veluchamy Amutha Baskaran, Mani Murukeshan, Vadakke Matham Noninvasive and noncontact sequential imaging of the iridocorneal angle and the cornea of the eye |
description |
High-resolution imaging of the critical anatomic structures of the eye, especially of the anterior chamber, in vivo, remains a challenge, even with currently available state-of-the-art medical imaging techniques. This study aims for the noninvasive and noncontact sequential imaging of the iridocorneal angle, especially the trabecular meshwork (TM) and the cornea of the eye in high-resolution using a newly developed imaging platform. |
author2 |
School of Mechanical and Aerospace Engineering |
author_facet |
School of Mechanical and Aerospace Engineering Hong, Jeesmond Xun Jie Suchand Sandeep, Chandramathi Sukumaran Shinoj, Vengalathunadakal Kuttinarayan Aung, Tin Barathi, Veluchamy Amutha Baskaran, Mani Murukeshan, Vadakke Matham |
format |
Article |
author |
Hong, Jeesmond Xun Jie Suchand Sandeep, Chandramathi Sukumaran Shinoj, Vengalathunadakal Kuttinarayan Aung, Tin Barathi, Veluchamy Amutha Baskaran, Mani Murukeshan, Vadakke Matham |
author_sort |
Hong, Jeesmond Xun Jie |
title |
Noninvasive and noncontact sequential imaging of the iridocorneal angle and the cornea of the eye |
title_short |
Noninvasive and noncontact sequential imaging of the iridocorneal angle and the cornea of the eye |
title_full |
Noninvasive and noncontact sequential imaging of the iridocorneal angle and the cornea of the eye |
title_fullStr |
Noninvasive and noncontact sequential imaging of the iridocorneal angle and the cornea of the eye |
title_full_unstemmed |
Noninvasive and noncontact sequential imaging of the iridocorneal angle and the cornea of the eye |
title_sort |
noninvasive and noncontact sequential imaging of the iridocorneal angle and the cornea of the eye |
publishDate |
2020 |
url |
https://hdl.handle.net/10356/144178 |
_version_ |
1759856080098164736 |