Investigation and mitigation of premature bearing degradation in motor drive system

Pulse width modulated (PWM) variable frequency drives (VFDs) are commonly adopted in modern control of electro-mechanical drive systems. The use of insulated-gate bipolar transistor (IGBT) and higher switching frequencies has improved the efficiency of the motor drive systems significantly but they...

全面介紹

Saved in:
書目詳細資料
Main Authors: Fan, Fei, See, Kye Yak, Banda, Joseph Kiran, Liu, Xiong, Gupta, Amit Kumar
其他作者: School of Electrical and Electronic Engineering
格式: Article
語言:English
出版: 2020
主題:
在線閱讀:https://hdl.handle.net/10356/144726
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
實物特徵
總結:Pulse width modulated (PWM) variable frequency drives (VFDs) are commonly adopted in modern control of electro-mechanical drive systems. The use of insulated-gate bipolar transistor (IGBT) and higher switching frequencies has improved the efficiency of the motor drive systems significantly but they also cause high frequency common-mode (CM) currents in the motor bearings. Hence, new drive installations failed prematurely within months, which resulted in unnecessary downtime. Mitigation techniques such as CM filter and motor shaft grounding ring are possible solutions to prevent this kind of premature failure. In this paper, using a 5.5 kW motor drive system as a case study, the cause of bearing degradation is investigated and the various mitigation techniques are carefully evaluated.