A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation
Coronary artery disease has emerged as one of the major diseases causing death worldwide. Coronary stent has great effect to improve blood flow to the myocardium subtended by that artery, in which bioresorbable vascular scaffolds are new-generation stents used by people. However, Coronary stents imp...
Saved in:
Main Authors: | , , , , , , , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | English |
Published: |
2020
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/145623 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Nanyang Technological University |
Language: | English |
id |
sg-ntu-dr.10356-145623 |
---|---|
record_format |
dspace |
spelling |
sg-ntu-dr.10356-1456232023-03-04T17:23:45Z A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation Lan, Yisha Zhou, Yuanhang Lu, Yiwen Wang, Hao Liu, Qing Ng, Eddie Yin Kwee Peng, Yonghong Hao, Yongtao Liu, Qinyuan Chen, Fei Cheng, Yongqiang Che, Wenliang School of Mechanical and Aerospace Engineering Engineering::Electrical and electronic engineering Bioabsorbable Vascular Scaffolds Optical Coherence Tomography Coronary artery disease has emerged as one of the major diseases causing death worldwide. Coronary stent has great effect to improve blood flow to the myocardium subtended by that artery, in which bioresorbable vascular scaffolds are new-generation stents used by people. However, Coronary stents implantation has a risk of restenosis, which is relative to hemodynamic parameters. Most of existing literatures studied in this issue have not taken into account such important factors as the strut thickness and lumen profile, and has yet to analyze the time effects among hemodynamic parameters over a certain period of time based on individual models. In this research, we proposed a framework to assess the chronic impact of hemodynamic on coronary stent implantation. In the framework, the optical coherence tomography (OCT) is combined with angiography to reconstruct patient-specific models of bioresorbable vascular scaffolds. Then, the hemodynamics parameters are extracted through the simulated 3D models, obtaining the distribution of wall shear stress (WSS), relative residence time (RRT) and oscillatory shear index (OSI). Finally, the changes of these parameters representing the effectiveness of hemodynamics exerted on the implanted stent can be assessed to estimate the chronic impacts. By a 9-month follow-up case study, it is observed that the difference of hemodynamic parameters are not significance. Both at baseline and 9-month follow-up experiments show that the hemodynamic parameters remain normal and similar, proving that the coronary stent implantation nowadays appears to have a robust and everlasting curative effect. Published version 2020-12-30T04:41:24Z 2020-12-30T04:41:24Z 2019 Journal Article Lan, Y., Zhou, Y., Lu, Y., Wang, H., Liu, Q., Ng, E. Y. K., . . . Che, W. (2019). A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation. IEEE Access, 7, 112564-112571. doi:10.1109/ACCESS.2019.2934155 2169-3536 https://hdl.handle.net/10356/145623 10.1109/ACCESS.2019.2934155 7 112564 112571 en IEEE Access © 2019 The Author(s). This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see http://creativecommons.org/licenses/by/4.0/ application/pdf |
institution |
Nanyang Technological University |
building |
NTU Library |
continent |
Asia |
country |
Singapore Singapore |
content_provider |
NTU Library |
collection |
DR-NTU |
language |
English |
topic |
Engineering::Electrical and electronic engineering Bioabsorbable Vascular Scaffolds Optical Coherence Tomography |
spellingShingle |
Engineering::Electrical and electronic engineering Bioabsorbable Vascular Scaffolds Optical Coherence Tomography Lan, Yisha Zhou, Yuanhang Lu, Yiwen Wang, Hao Liu, Qing Ng, Eddie Yin Kwee Peng, Yonghong Hao, Yongtao Liu, Qinyuan Chen, Fei Cheng, Yongqiang Che, Wenliang A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation |
description |
Coronary artery disease has emerged as one of the major diseases causing death worldwide. Coronary stent has great effect to improve blood flow to the myocardium subtended by that artery, in which bioresorbable vascular scaffolds are new-generation stents used by people. However, Coronary stents implantation has a risk of restenosis, which is relative to hemodynamic parameters. Most of existing literatures studied in this issue have not taken into account such important factors as the strut thickness and lumen profile, and has yet to analyze the time effects among hemodynamic parameters over a certain period of time based on individual models. In this research, we proposed a framework to assess the chronic impact of hemodynamic on coronary stent implantation. In the framework, the optical coherence tomography (OCT) is combined with angiography to reconstruct patient-specific models of bioresorbable vascular scaffolds. Then, the hemodynamics parameters are extracted through the simulated 3D models, obtaining the distribution of wall shear stress (WSS), relative residence time (RRT) and oscillatory shear index (OSI). Finally, the changes of these parameters representing the effectiveness of hemodynamics exerted on the implanted stent can be assessed to estimate the chronic impacts. By a 9-month follow-up case study, it is observed that the difference of hemodynamic parameters are not significance. Both at baseline and 9-month follow-up experiments show that the hemodynamic parameters remain normal and similar, proving that the coronary stent implantation nowadays appears to have a robust and everlasting curative effect. |
author2 |
School of Mechanical and Aerospace Engineering |
author_facet |
School of Mechanical and Aerospace Engineering Lan, Yisha Zhou, Yuanhang Lu, Yiwen Wang, Hao Liu, Qing Ng, Eddie Yin Kwee Peng, Yonghong Hao, Yongtao Liu, Qinyuan Chen, Fei Cheng, Yongqiang Che, Wenliang |
format |
Article |
author |
Lan, Yisha Zhou, Yuanhang Lu, Yiwen Wang, Hao Liu, Qing Ng, Eddie Yin Kwee Peng, Yonghong Hao, Yongtao Liu, Qinyuan Chen, Fei Cheng, Yongqiang Che, Wenliang |
author_sort |
Lan, Yisha |
title |
A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation |
title_short |
A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation |
title_full |
A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation |
title_fullStr |
A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation |
title_full_unstemmed |
A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation |
title_sort |
nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation |
publishDate |
2020 |
url |
https://hdl.handle.net/10356/145623 |
_version_ |
1759854114426060800 |