A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation

Coronary artery disease has emerged as one of the major diseases causing death worldwide. Coronary stent has great effect to improve blood flow to the myocardium subtended by that artery, in which bioresorbable vascular scaffolds are new-generation stents used by people. However, Coronary stents imp...

Full description

Saved in:
Bibliographic Details
Main Authors: Lan, Yisha, Zhou, Yuanhang, Lu, Yiwen, Wang, Hao, Liu, Qing, Ng, Eddie Yin Kwee, Peng, Yonghong, Hao, Yongtao, Liu, Qinyuan, Chen, Fei, Cheng, Yongqiang, Che, Wenliang
Other Authors: School of Mechanical and Aerospace Engineering
Format: Article
Language:English
Published: 2020
Subjects:
Online Access:https://hdl.handle.net/10356/145623
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-145623
record_format dspace
spelling sg-ntu-dr.10356-1456232023-03-04T17:23:45Z A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation Lan, Yisha Zhou, Yuanhang Lu, Yiwen Wang, Hao Liu, Qing Ng, Eddie Yin Kwee Peng, Yonghong Hao, Yongtao Liu, Qinyuan Chen, Fei Cheng, Yongqiang Che, Wenliang School of Mechanical and Aerospace Engineering Engineering::Electrical and electronic engineering Bioabsorbable Vascular Scaffolds Optical Coherence Tomography Coronary artery disease has emerged as one of the major diseases causing death worldwide. Coronary stent has great effect to improve blood flow to the myocardium subtended by that artery, in which bioresorbable vascular scaffolds are new-generation stents used by people. However, Coronary stents implantation has a risk of restenosis, which is relative to hemodynamic parameters. Most of existing literatures studied in this issue have not taken into account such important factors as the strut thickness and lumen profile, and has yet to analyze the time effects among hemodynamic parameters over a certain period of time based on individual models. In this research, we proposed a framework to assess the chronic impact of hemodynamic on coronary stent implantation. In the framework, the optical coherence tomography (OCT) is combined with angiography to reconstruct patient-specific models of bioresorbable vascular scaffolds. Then, the hemodynamics parameters are extracted through the simulated 3D models, obtaining the distribution of wall shear stress (WSS), relative residence time (RRT) and oscillatory shear index (OSI). Finally, the changes of these parameters representing the effectiveness of hemodynamics exerted on the implanted stent can be assessed to estimate the chronic impacts. By a 9-month follow-up case study, it is observed that the difference of hemodynamic parameters are not significance. Both at baseline and 9-month follow-up experiments show that the hemodynamic parameters remain normal and similar, proving that the coronary stent implantation nowadays appears to have a robust and everlasting curative effect. Published version 2020-12-30T04:41:24Z 2020-12-30T04:41:24Z 2019 Journal Article Lan, Y., Zhou, Y., Lu, Y., Wang, H., Liu, Q., Ng, E. Y. K., . . . Che, W. (2019). A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation. IEEE Access, 7, 112564-112571. doi:10.1109/ACCESS.2019.2934155 2169-3536 https://hdl.handle.net/10356/145623 10.1109/ACCESS.2019.2934155 7 112564 112571 en IEEE Access © 2019 The Author(s). This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see http://creativecommons.org/licenses/by/4.0/ application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Electrical and electronic engineering
Bioabsorbable Vascular Scaffolds
Optical Coherence Tomography
spellingShingle Engineering::Electrical and electronic engineering
Bioabsorbable Vascular Scaffolds
Optical Coherence Tomography
Lan, Yisha
Zhou, Yuanhang
Lu, Yiwen
Wang, Hao
Liu, Qing
Ng, Eddie Yin Kwee
Peng, Yonghong
Hao, Yongtao
Liu, Qinyuan
Chen, Fei
Cheng, Yongqiang
Che, Wenliang
A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation
description Coronary artery disease has emerged as one of the major diseases causing death worldwide. Coronary stent has great effect to improve blood flow to the myocardium subtended by that artery, in which bioresorbable vascular scaffolds are new-generation stents used by people. However, Coronary stents implantation has a risk of restenosis, which is relative to hemodynamic parameters. Most of existing literatures studied in this issue have not taken into account such important factors as the strut thickness and lumen profile, and has yet to analyze the time effects among hemodynamic parameters over a certain period of time based on individual models. In this research, we proposed a framework to assess the chronic impact of hemodynamic on coronary stent implantation. In the framework, the optical coherence tomography (OCT) is combined with angiography to reconstruct patient-specific models of bioresorbable vascular scaffolds. Then, the hemodynamics parameters are extracted through the simulated 3D models, obtaining the distribution of wall shear stress (WSS), relative residence time (RRT) and oscillatory shear index (OSI). Finally, the changes of these parameters representing the effectiveness of hemodynamics exerted on the implanted stent can be assessed to estimate the chronic impacts. By a 9-month follow-up case study, it is observed that the difference of hemodynamic parameters are not significance. Both at baseline and 9-month follow-up experiments show that the hemodynamic parameters remain normal and similar, proving that the coronary stent implantation nowadays appears to have a robust and everlasting curative effect.
author2 School of Mechanical and Aerospace Engineering
author_facet School of Mechanical and Aerospace Engineering
Lan, Yisha
Zhou, Yuanhang
Lu, Yiwen
Wang, Hao
Liu, Qing
Ng, Eddie Yin Kwee
Peng, Yonghong
Hao, Yongtao
Liu, Qinyuan
Chen, Fei
Cheng, Yongqiang
Che, Wenliang
format Article
author Lan, Yisha
Zhou, Yuanhang
Lu, Yiwen
Wang, Hao
Liu, Qing
Ng, Eddie Yin Kwee
Peng, Yonghong
Hao, Yongtao
Liu, Qinyuan
Chen, Fei
Cheng, Yongqiang
Che, Wenliang
author_sort Lan, Yisha
title A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation
title_short A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation
title_full A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation
title_fullStr A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation
title_full_unstemmed A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation
title_sort nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation
publishDate 2020
url https://hdl.handle.net/10356/145623
_version_ 1759854114426060800