Stability-constrained two-stage robust optimization for integrated hydrogen hybrid energy system

In order to cope with the challenges brought by multiple uncertainties to integrated hydrogen hybrid energy systems, a stability-constrained two-stage robust optimization method considering small disturbance stability and characteristics of dynamic response is proposed in this paper. In the first op...

Full description

Saved in:
Bibliographic Details
Main Authors: Li, Qi, Qiu, Yibin, Yang, Hanqing, Xu, Yan, Chen, Weirong, Wang, Peng
Other Authors: School of Electrical and Electronic Engineering
Format: Article
Language:English
Published: 2021
Subjects:
Online Access:https://hdl.handle.net/10356/146681
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-146681
record_format dspace
spelling sg-ntu-dr.10356-1466812021-03-04T08:49:16Z Stability-constrained two-stage robust optimization for integrated hydrogen hybrid energy system Li, Qi Qiu, Yibin Yang, Hanqing Xu, Yan Chen, Weirong Wang, Peng School of Electrical and Electronic Engineering Engineering::Electrical and electronic engineering Eigenvalue Analysis Integrated Hydrogen Hybrid Energy System In order to cope with the challenges brought by multiple uncertainties to integrated hydrogen hybrid energy systems, a stability-constrained two-stage robust optimization method considering small disturbance stability and characteristics of dynamic response is proposed in this paper. In the first operating stage, the charging/discharging state of the battery and the start-stop state of the electrolyzer and fuel cell are determined. Then, power constraints for stabilizing ESSs power output is considered between the first and second stage optimization to improve the small disturbance stability of the robust operation plan. Then, the goal of minimizing the operation cost and determine a robust operation operating plan under the worst case is conducting in the second stage optimization. Through the small-signal model with time-delay effect, the eigenvalue analysis method is used to find the ESSs power range, and the small-signal stability of obtained robust operation plan can be enhanced. Finally, the effectiveness and superiority of the proposed method are proved by comparing with the traditional static robust optimization method. Impacts of uncertain parameters on economy and stability are also investigated in a typical example. Published version 2021-03-04T08:49:15Z 2021-03-04T08:49:15Z 2020 Journal Article Li, Q., Qiu, Y., Yang, H., Xu, Y., Chen, W., & Wang, P. (2021). Stability-constrained two-stage robust optimization for integrated hydrogen hybrid energy system. CSEE Journal of Power and Energy Systems, 7(1), 162-171. doi:10.17775/CSEEJPES.2020.00810 2096-0042 0000-0001-5395-9731 0000-0003-2670-4770 https://hdl.handle.net/10356/146681 10.17775/CSEEJPES.2020.00810 2-s2.0-85099132393 1 7 162 171 en CSEE Journal of Power and Energy Systems © 2020 CSEE. This is an open-access article distributed under the terms of the Creative Commons Attribution License. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Electrical and electronic engineering
Eigenvalue Analysis
Integrated Hydrogen Hybrid Energy System
spellingShingle Engineering::Electrical and electronic engineering
Eigenvalue Analysis
Integrated Hydrogen Hybrid Energy System
Li, Qi
Qiu, Yibin
Yang, Hanqing
Xu, Yan
Chen, Weirong
Wang, Peng
Stability-constrained two-stage robust optimization for integrated hydrogen hybrid energy system
description In order to cope with the challenges brought by multiple uncertainties to integrated hydrogen hybrid energy systems, a stability-constrained two-stage robust optimization method considering small disturbance stability and characteristics of dynamic response is proposed in this paper. In the first operating stage, the charging/discharging state of the battery and the start-stop state of the electrolyzer and fuel cell are determined. Then, power constraints for stabilizing ESSs power output is considered between the first and second stage optimization to improve the small disturbance stability of the robust operation plan. Then, the goal of minimizing the operation cost and determine a robust operation operating plan under the worst case is conducting in the second stage optimization. Through the small-signal model with time-delay effect, the eigenvalue analysis method is used to find the ESSs power range, and the small-signal stability of obtained robust operation plan can be enhanced. Finally, the effectiveness and superiority of the proposed method are proved by comparing with the traditional static robust optimization method. Impacts of uncertain parameters on economy and stability are also investigated in a typical example.
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Li, Qi
Qiu, Yibin
Yang, Hanqing
Xu, Yan
Chen, Weirong
Wang, Peng
format Article
author Li, Qi
Qiu, Yibin
Yang, Hanqing
Xu, Yan
Chen, Weirong
Wang, Peng
author_sort Li, Qi
title Stability-constrained two-stage robust optimization for integrated hydrogen hybrid energy system
title_short Stability-constrained two-stage robust optimization for integrated hydrogen hybrid energy system
title_full Stability-constrained two-stage robust optimization for integrated hydrogen hybrid energy system
title_fullStr Stability-constrained two-stage robust optimization for integrated hydrogen hybrid energy system
title_full_unstemmed Stability-constrained two-stage robust optimization for integrated hydrogen hybrid energy system
title_sort stability-constrained two-stage robust optimization for integrated hydrogen hybrid energy system
publishDate 2021
url https://hdl.handle.net/10356/146681
_version_ 1695706182686081024