Osmotic oedometer using sodium chloride solution and reverse osmosis membrane

There are two suction application techniques in laboratory testing of unsaturated soils: (1) the axis-translation technique in which pore-air pressure is elevated above atmospheric pressure and pore-water pressure is at an atmospheric or a small positive value to give a matric suction and (2) using...

Full description

Saved in:
Bibliographic Details
Main Authors: Bulolo, Sam, Leong, Eng Choon
Other Authors: School of Civil and Environmental Engineering
Format: Article
Language:English
Published: 2021
Subjects:
Online Access:https://hdl.handle.net/10356/148669
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Nanyang Technological University
Language: English
id sg-ntu-dr.10356-148669
record_format dspace
spelling sg-ntu-dr.10356-1486692021-09-10T01:00:17Z Osmotic oedometer using sodium chloride solution and reverse osmosis membrane Bulolo, Sam Leong, Eng Choon School of Civil and Environmental Engineering Engineering::Civil engineering Osmotic Technique Matric Suction There are two suction application techniques in laboratory testing of unsaturated soils: (1) the axis-translation technique in which pore-air pressure is elevated above atmospheric pressure and pore-water pressure is at an atmospheric or a small positive value to give a matric suction and (2) using salt solutions. Salt solutions can be used to control the relative humidity of the air surrounding the soil specimen in the vapor equilibrium technique or as an osmotic suction applied through a semipermeable membrane in the osmotic technique. The salt solution in the vapor equilibrium technique applies a total suction, whereas the salt solution in the osmotic technique induces a matric suction on the soil specimen. Unlike the axis-translation technique and vapor equilibrium technique, the osmotic technique does not require a sealed chamber, but it is not as popular as the axis-translation technique and vapor equilibrium technique because the commonly used poly(ethylene glycol) solution and cellulosic membrane are susceptible to degradation during long-duration tests. This paper investigates the osmotic technique using sodium chloride solutions and a reverse osmosis membrane in a conventional oedometer. The performance of the updated osmotic oedometer was evaluated using kaolin–bentonite specimens. A kaolin–bentonite specimen was first mechanically consolidated, and thereafter the water within the base of the oedometer was replaced with sodium chloride solution. The results show that osmotic technique causes the soil specimen to be compressed further. However, the measured matric suction of the soil specimen at equilibrium is less than the applied suction. The difference is attributed to the membrane resistance effect. The updated osmotic oedometer is attractive, as it eliminates the drawbacks of the previous osmotic oedometer, and it can theoretically apply matric suction as high as 5,000 kPa. Published version 2021-09-10T01:00:17Z 2021-09-10T01:00:17Z 2020 Journal Article Bulolo, S. & Leong, E. C. (2020). Osmotic oedometer using sodium chloride solution and reverse osmosis membrane. Geotechnical Testing Journal, 44(2), 483-501. https://dx.doi.org/10.1520/GTJ20190403 0149-6115 0000-0002-0941-0984 https://hdl.handle.net/10356/148669 10.1520/GTJ20190403 2-s2.0-85092618707 2 44 483 501 en Geotechnical Testing Journal © 2020 ASTM International. All rights reserved. This paper was published in Geotechnical Testing Journal and is made available with permission of ASTM International. application/pdf
institution Nanyang Technological University
building NTU Library
continent Asia
country Singapore
Singapore
content_provider NTU Library
collection DR-NTU
language English
topic Engineering::Civil engineering
Osmotic Technique
Matric Suction
spellingShingle Engineering::Civil engineering
Osmotic Technique
Matric Suction
Bulolo, Sam
Leong, Eng Choon
Osmotic oedometer using sodium chloride solution and reverse osmosis membrane
description There are two suction application techniques in laboratory testing of unsaturated soils: (1) the axis-translation technique in which pore-air pressure is elevated above atmospheric pressure and pore-water pressure is at an atmospheric or a small positive value to give a matric suction and (2) using salt solutions. Salt solutions can be used to control the relative humidity of the air surrounding the soil specimen in the vapor equilibrium technique or as an osmotic suction applied through a semipermeable membrane in the osmotic technique. The salt solution in the vapor equilibrium technique applies a total suction, whereas the salt solution in the osmotic technique induces a matric suction on the soil specimen. Unlike the axis-translation technique and vapor equilibrium technique, the osmotic technique does not require a sealed chamber, but it is not as popular as the axis-translation technique and vapor equilibrium technique because the commonly used poly(ethylene glycol) solution and cellulosic membrane are susceptible to degradation during long-duration tests. This paper investigates the osmotic technique using sodium chloride solutions and a reverse osmosis membrane in a conventional oedometer. The performance of the updated osmotic oedometer was evaluated using kaolin–bentonite specimens. A kaolin–bentonite specimen was first mechanically consolidated, and thereafter the water within the base of the oedometer was replaced with sodium chloride solution. The results show that osmotic technique causes the soil specimen to be compressed further. However, the measured matric suction of the soil specimen at equilibrium is less than the applied suction. The difference is attributed to the membrane resistance effect. The updated osmotic oedometer is attractive, as it eliminates the drawbacks of the previous osmotic oedometer, and it can theoretically apply matric suction as high as 5,000 kPa.
author2 School of Civil and Environmental Engineering
author_facet School of Civil and Environmental Engineering
Bulolo, Sam
Leong, Eng Choon
format Article
author Bulolo, Sam
Leong, Eng Choon
author_sort Bulolo, Sam
title Osmotic oedometer using sodium chloride solution and reverse osmosis membrane
title_short Osmotic oedometer using sodium chloride solution and reverse osmosis membrane
title_full Osmotic oedometer using sodium chloride solution and reverse osmosis membrane
title_fullStr Osmotic oedometer using sodium chloride solution and reverse osmosis membrane
title_full_unstemmed Osmotic oedometer using sodium chloride solution and reverse osmosis membrane
title_sort osmotic oedometer using sodium chloride solution and reverse osmosis membrane
publishDate 2021
url https://hdl.handle.net/10356/148669
_version_ 1710686960079601664